journal article·2026-06Open access

Hot‐Film and Calorimetric Methods With Transient Heating for Measurement of High Biofluid Flow Rate

Yuanting Wei, Shupeng Li, Kyung Rok Pyun, Tianyu Yang, Bosung Kim, Haotian Yang, John A. Rogers, Yonggang Huang, Haohui Zhang

Advanced Functional Materials· Volume 36· Issue 50

Abstract

ABSTRACT Accurate measurement of biofluid flow rate is critical for clinical diagnostics and physiological monitoring, such as in cerebrospinal fluid shunt assessment and vascular blood flow evaluation. Thermal flow sensors, particularly hot‐film and calorimetric types, are widely used in biomedical settings due to their broad dynamic range and long‐term stability. However, their performance declines at high flow rates. To overcome this drawback, we propose a transient heating method that applies a short‐duration thermal pulse and tracks the peak temperature response. This method, validated by experiments using artificial blood and vessels, significantly improves sensitivity to the flow rate change at high flow rates and reduces energy consumption. There exists an optimal heating time to maximize sensitivity to the flow rate. A contour plot of flow rate sensitivity vs. the heating time and flow rate is obtained to guide the selection of optimal heating time for different flow conditions.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: thermodynamics and calorimetric analyses · Thermal Regulation in Medicine · Infrared Thermography in Medicine

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Civil and Environmental Engineering Northwestern University Evanston Illinois USA

Querrey Simpson Institute For Bioelectronics Northwestern University Evanston Illinois USA

School For Engineering of Matter Transport and Energy Arizona State University Tempe Arizona USA

Department of Mechanical Engineering Northwestern University Evanston Illinois USA

Department of Materials Science and Engineering Northwestern University Evanston Illinois USA

Department of Biomedical Engineering Northwestern University Evanston Illinois USA

Department of Neurological Surgery Feinberg School of Medicine Northwestern University Chicago Illinois USA

References (45)

Show source-provided references
1. 10.1038/s41746‐020‐0239‐110.1038/s41746‐020‐0239‐1 ↗
2. 10.1126/scitranslmed.aat843710.1126/scitranslmed.aat8437 ↗
3. 10.1109/TBME.2006.88685310.1109/TBME.2006.886853 ↗
4. 10.1007/s10544‐016‐0112‐910.1007/s10544‐016‐0112‐9 ↗
5. 10.1038/s41928‐021‐00556‐210.1038/s41928‐021‐00556‐2 ↗
6. 10.1126/sciadv.150070110.1126/sciadv.1500701 ↗
7. 10.1016/j.bios.2022.11414510.1016/j.bios.2022.114145 ↗
8. 10.1038/s41528‐024‐00342‐y10.1038/s41528‐024‐00342‐y ↗
9. D.VilkomersonandT.Chilipka “Implantable Doppler System for Self‐Monitoring Vascular Grafts ” inIEEE Ultrasonics Symposium(IEEE 2004) https://doi.org/10.1109/ULTSYM.2004.1417762.10.1109/ULTSYM.2004.1417762 ↗
10. 10.1038/s41551‐023‐01022‐410.1038/s41551‐023‐01022‐4 ↗
11. 10.1038/s41598‐019‐44784‐110.1038/s41598‐019‐44784‐1 ↗
12. 10.1371/journal.pone.022737210.1371/journal.pone.0227372 ↗
13. 10.3390/mi303055010.3390/mi3030550 ↗
14. 10.3390/mi302022510.3390/mi3020225 ↗
15. 10.1016/S0955‐5986(97)00019‐810.1016/S0955‐5986(97)00019‐8 ↗
16. 10.1039/D2LC00188H10.1039/D2LC00188H ↗
17. 10.3390/s15122988110.3390/s151229881 ↗
18. 10.1016/j.bios.2020.11228810.1016/j.bios.2020.112288 ↗
19. 10.1038/s41467‐024‐54942‐310.1038/s41467‐024‐54942‐3 ↗
20. 10.1016/j.sna.2018.06.02510.1016/j.sna.2018.06.025 ↗
21. 10.1017/CBO978051176072310.1017/CBO9780511760723 ↗
22. Bruus H. · 2007
23. Fung Y. C. · 2013
24. 10.1146/annurev.fluid.29.1.39910.1146/annurev.fluid.29.1.399 ↗
25. 10.1093/clinchem/42.8.118910.1093/clinchem/42.8.1189 ↗
26. 10.3389/fphys.2019.0132910.3389/fphys.2019.01329 ↗
27. Bergman T. L. · 2011
28. 10.1115/1.142429810.1115/1.1424298 ↗
29. 10.3389/fnins.2014.0030710.3389/fnins.2014.00307 ↗
30. 10.2741/360810.2741/3608 ↗
31. 10.1097/01.BCR.0000138295.63830.9010.1097/01.BCR.0000138295.63830.90 ↗
32. 10.1016/j.otohns.2008.12.00410.1016/j.otohns.2008.12.004 ↗
33. 10.1080/026567303100011900610.1080/0265673031000119006 ↗
34. 10.1016/S0924‐4247(00)00541‐010.1016/S0924‐4247(00)00541‐0 ↗
35. 10.1016/j.snb.2015.11.00910.1016/j.snb.2015.11.009 ↗
36. 10.1016/S0924‐4247(00)00503‐310.1016/S0924‐4247(00)00503‐3 ↗
37. 10.1021/acs.nanolett.3c0105010.1021/acs.nanolett.3c01050 ↗
38. 10.1148/radiol.229203051610.1148/radiol.2292030516 ↗
39. 10.1007/s00348‐010‐0958‐110.1007/s00348‐010‐0958‐1 ↗
40. M. Y.Yousif D. W.Holdsworth andT. L.Poepping “Deriving A Blood‐Mimicking Fluid for Particle Image Velocimetry in Sylgard‐184 Vascular Models ” in2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society(IEEE 2009) 1412–1415 https://doi.org/10.1109/IEMBS.2009.5334175.10.1109/IEMBS.2009.5334175 ↗
41. 10.1038/s41593‐021‐00849‐x10.1038/s41593‐021‐00849‐x ↗
42. Glycerine Producers' Association · 1963 · 5
43. 10.1016/j.jmps.2022.10511910.1016/j.jmps.2022.105119 ↗
44. 10.1016/j.ijheatmasstransfer.2020.12055010.1016/j.ijheatmasstransfer.2020.120550 ↗
45. 10.1038/s41928‐021‐00556‐210.1038/s41928‐021‐00556‐2 ↗