journal article·2017-03

Thin, Soft, Skin‐Mounted Microfluidic Networks with Capillary Bursting Valves for Chrono‐Sampling of Sweat

Jungil Choi, Daeshik Kang, Seungyong Han, Sung Bong Kim, John A. Rogers

Advanced Healthcare Materials· Volume 6· Issue 5
Publisher page

Abstract

Systems for time sequential capture of microliter volumes of sweat released from targeted regions of the skin offer the potential to enable analysis of temporal variations in electrolyte balance and biomarker concentration throughout a period of interest. Current methods that rely on absorbent pads taped to the skin do not offer the ease of use in sweat capture needed for quantitative tracking; emerging classes of electronic wearable sweat analysis systems do not directly manage sweat‐induced fluid flows for sample isolation. Here, a thin, soft, “skin‐like” microfluidic platform is introduced that bonds to the skin to allow for collection and storage of sweat in an interconnected set of microreservoirs. Pressure induced by the sweat glands drives flow through a network of microchannels that incorporates capillary bursting valves designed to open at different pressures, for the purpose of passively guiding sweat through the system in sequential fashion. A representative device recovers 1.8 µL volumes of sweat each from 0.8 min of sweating into a set of separate microreservoirs, collected from 0.03 cm2 area of skin with approximately five glands, corresponding to a sweat rate of 0.60 µL min−1 per gland. Human studies demonstrate applications in the accurate chemical analysis of lactate, sodium, and potassium concentrations and their temporal variations.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Advanced Sensor and Energy Harvesting Materials · Microfluidic and Capillary Electrophoresis Applications · Tactile and Sensory Interactions

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Materials Science and Engineering Northwestern University Evanston IL 60208 USA

Department of Mechanical Engineering Ajou University San 5, Woncheon‐Dong Yeongtong‐Gu, Suwon 16499 South Korea

Department of Materials Science and Engineering Frederick Seitz Materials Research Laboratory University of Illinois at Urbana‐Champaign Urbana IL 61801 USA

Center for Bio‐Integrated Electronics Departments of Materials Science and Engineering, Biomedical Engineering, Chemistry, Mechanical Engineering, Electrical Engineering and Computer Science, and Neurological Surgery Simpson Querrey Institute for Nano/Biotechnology McCormick School of Engineering and Feinberg School of Medicine Northwestern University Evanston IL 60208 USA

Funding

Ministry of Science, ICT and Future Planning

References (61)

Show source-provided references
1. 10.1016/j.jpba.2013.10.04810.1016/j.jpba.2013.10.048 ↗
2. 10.1152/jappl.1974.37.2.24710.1152/jappl.1974.37.2.247 ↗
3. 10.1542/peds.23.3.54510.1542/peds.23.3.545 ↗
4. 10.1016/0002-9343(53)90169-710.1016/0002-9343(53)90169-7 ↗
5. 10.1152/jappl.1984.56.5.130210.1152/jappl.1984.56.5.1302 ↗
6. 10.1002/clc.496011101010.1002/clc.4960111010 ↗
7. 10.1007/s00421-005-1314-710.1007/s00421-005-1314-7 ↗
8. 10.1113/jphysiol.1952.sp00471310.1113/jphysiol.1952.sp004713 ↗
9. 10.1186/2046-7648-2-410.1186/2046-7648-2-4 ↗
10. 10.1016/S0379-0738(00)00353-410.1016/S0379-0738(00)00353-4 ↗
11. 10.1016/S0022-3476(94)70314-010.1016/S0022-3476(94)70314-0 ↗
12. 10.1039/C2AN36422K10.1039/C2AN36422K ↗
13. 10.1039/c3an01672b10.1039/c3an01672b ↗
14. 10.1016/j.bios.2013.11.03910.1016/j.bios.2013.11.039 ↗
15. 10.1016/j.elecom.2014.11.02410.1016/j.elecom.2014.11.024 ↗
16. 10.1038/nature1652110.1038/nature16521 ↗
17. 10.1038/ncomms1165010.1038/ncomms11650 ↗
18. 10.1021/acsnano.6b0400510.1021/acsnano.6b04005 ↗
19. 10.1002/smll.20140048310.1002/smll.201400483 ↗
20. 10.1039/b9ay00184k10.1039/b9ay00184k ↗
21. 10.1109/TBME.2014.236999110.1109/TBME.2014.2369991 ↗
22. 10.1039/C6LC00926C10.1039/C6LC00926C ↗
23. 10.1002/elan.20160001810.1002/elan.201600018 ↗
24. Yeo J. C. · Small · 2016
25. 10.1021/acssensors.6b0011510.1021/acssensors.6b00115 ↗
26. 10.1039/C6LC00579A10.1039/C6LC00579A ↗
27. 10.1038/micronano.2016.3910.1038/micronano.2016.39 ↗
28. 10.1016/j.cell.2015.06.05810.1016/j.cell.2015.06.058 ↗
29. 10.1016/j.snb.2009.02.03210.1016/j.snb.2009.02.032 ↗
30. 10.1016/j.snb.2012.02.01010.1016/j.snb.2012.02.010 ↗
31. 10.1126/scitranslmed.aaf259310.1126/scitranslmed.aaf2593 ↗
32. 10.1172/JCI10611310.1172/JCI106113 ↗
33. 10.1063/1.492103910.1063/1.4921039 ↗
34. 10.1109/JMEMS.2002.80504810.1109/JMEMS.2002.805048 ↗
35. 10.1109/JMEMS.2002.80505510.1109/JMEMS.2002.805055 ↗
36. 10.1021/ac020269w10.1021/ac020269w ↗
37. 10.1007/s10404-007-0196-x10.1007/s10404-007-0196-x ↗
38. 10.1177/221106821558845610.1177/2211068215588456 ↗
39. 10.1146/annurev.bioeng.8.061505.09575810.1146/annurev.bioeng.8.061505.095758 ↗
40. 10.1002/smll.20110228210.1002/smll.201102282 ↗
41. 10.1039/C2LC41055A10.1039/C2LC41055A ↗
42. 10.1039/c1lc20714h10.1039/c1lc20714h ↗
43. 10.1021/ac034671210.1021/ac0346712 ↗
44. 10.1016/j.bios.2014.07.02910.1016/j.bios.2014.07.029 ↗
45. 10.1063/1.128981610.1063/1.1289816 ↗
46. 10.1126/science.112140110.1126/science.1121401 ↗
47. 10.1088/0960-1317/7/3/01710.1088/0960-1317/7/3/017 ↗
48. 10.1007/s10439-012-0562-z10.1007/s10439-012-0562-z ↗
49. 10.1016/j.jcis.2006.10.07710.1016/j.jcis.2006.10.077 ↗
50. 10.1039/b818401a10.1039/b818401a ↗
51. 10.1016/j.snb.2005.04.03710.1016/j.snb.2005.04.037 ↗
52. 10.1088/0960-1317/17/5/02310.1088/0960-1317/17/5/023 ↗
53. 10.1039/b502031j10.1039/b502031j ↗
54. 10.1021/pr030003l10.1021/pr030003l ↗
55. 10.1021/ja207515j10.1021/ja207515j ↗
56. 10.1152/ajpcell.1983.245.3.C18910.1152/ajpcell.1983.245.3.C189 ↗
57. 10.1016/j.athoracsur.2004.02.08710.1016/j.athoracsur.2004.02.087 ↗
58. 10.1186/2046-7648-2-410.1186/2046-7648-2-4 ↗
59. 10.1093/ajcn/22.1.5210.1093/ajcn/22.1.52 ↗
60. Mickelsen O. · J. Biol. Chem. · 1943 · 149 · 47910.1016/S0021-9258(18)72194-7 ↗
61. 10.1039/C6LC01013J10.1039/C6LC01013J ↗