journal article·2019-08

Bioresorbable Electrode Array for Electrophysiological and Pressure Signal Recording in the Brain

Kedi Xu, Shijian Li, Shurong Dong, Shaomin Zhang, Gang Pan, Guangming Wang, Lin Shi, Wei Guo, Chaonan Yu, Jikui Luo

Advanced Healthcare Materials· Volume 8· Issue 15
Publisher page

Abstract

Medical implantation of an electrocorticography (ECoG) recording system for brain monitoring is an effective clinical tool for seizure focus location and brain disease diagnosis. Planar and flexible ECoG electrodes can minimize the risks of infection and serious inflammatory response, and their good shape adaptability allows the device to fit complex cortex shape and structure to record brain signals with high spatial and temporal resolution. However, these ECoG electrodes require an additional surgery to remove the implant, which imposes potential medical risks. Here, a novel flexible and bioresorbable ECoG device integrated with an intracortical pressure sensor for monitoring swelling of the cortex during operation is reported. The ECoG device is fabricated with poly(l‐lactide) and polycaprolactone composite and transient metal molybdenum. In vivo tests on rats show that the ECoG system can record the dynamic changes in brain signals for the different epilepsy stages with high resolution, while the malleable pressure sensor shows a linear relationship between the pressure and resistance in in vitro tests. In vitro degradation experiments show that the ECoG system can work stably for about five days before loss of efficacy, and the whole ECoG system degrades completely in a phosphate buffer solution in about 100 days.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Neuroscience and Neural Engineering · EEG and Brain-Computer Interfaces · Neurological disorders and treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Key Laboratory of Biomedical Engineering of Education Ministry Qiushi Academy for Advanced Studies Department of Biomedical Engineering Zhejiang University Hangzhou 310027 China

College of Computer Science Zhejiang University Hangzhou 310027 China

College of Information Science and Electronic Engineering Zhejiang University Hangzhou 310027 China

Institute of Renewable Energy and Environmental Technology Bolton University Deane Road Bolton BL3 5AB UK

Funding

National Natural Science Foundation of China

References (40)

Show source-provided references
1. Penfield W. · Q. Rev. Biol. · 1968 · 235 · 227
2. 10.1021/cn500286410.1021/cn5002864 ↗
3. 10.1016/j.jmps.2006.05.00410.1016/j.jmps.2006.05.004 ↗
4. 10.1016/S0021-9290(01)00234-210.1016/S0021-9290(01)00234-2 ↗
5. 10.1007/s11340-011-9481-410.1007/s11340-011-9481-4 ↗
6. 10.1016/j.conb.2010.09.01010.1016/j.conb.2010.09.010 ↗
7. 10.1109/TBME.2003.82032110.1109/TBME.2003.820321 ↗
8. 10.1007/s11517-010-0644-810.1007/s11517-010-0644-8 ↗
9. 10.1109/TBME.2007.89575310.1109/TBME.2007.895753 ↗
10. 10.1016/j.jneuroim.2004.10.01010.1016/j.jneuroim.2004.10.010 ↗
11. 10.1021/acsnano.5b0788910.1021/acsnano.5b07889 ↗
12. Chen B. · Analog Devices, Inc. · 2006
13. 10.1016/j.vacuum.2016.12.02410.1016/j.vacuum.2016.12.024 ↗
14. 10.1016/j.sna.2013.04.00510.1016/j.sna.2013.04.005 ↗
15. 10.1109/JSTSP.2013.223983110.1109/JSTSP.2013.2239831 ↗
16. Li H. U. · 2016
17. Takeshi M. · Front. Syst. Neurosci. · 2011 · 5 · 34
18. 10.1063/1.491375110.1063/1.4913751 ↗
19. 10.1161/hc3401.09509710.1161/hc3401.095097 ↗
20. 10.1038/nrmicro82110.1038/nrmicro821 ↗
21. 10.1161/CIRCEP.110.95410710.1161/CIRCEP.110.954107 ↗
22. 10.1080/0268869050049529910.1080/02688690500495299 ↗
23. 10.1038/nmat462410.1038/nmat4624 ↗
24. 10.1208/s12249-011-9714-y10.1208/s12249-011-9714-y ↗
25. 10.1109/MMM.2014.237758510.1109/MMM.2014.2377585 ↗
26. 10.1109/TBCAS.2018.284546210.1109/TBCAS.2018.2845462 ↗
27. 10.1016/S0013-4686(98)00180-710.1016/S0013-4686(98)00180-7 ↗
28. 10.1088/1741-2560/12/5/05601810.1088/1741-2560/12/5/056018 ↗
29. 10.3389/fnins.2014.0042310.3389/fnins.2014.00423 ↗
30. 10.3389/fneng.2014.0000810.3389/fneng.2014.00008 ↗
31. 10.1038/ncomms625810.1038/ncomms6258 ↗
32. 10.1088/1741-2560/6/3/03600310.1088/1741-2560/6/3/036003 ↗
33. 10.1016/j.polymdegradstab.2012.06.03110.1016/j.polymdegradstab.2012.06.031 ↗
34. 10.1227/00006123-199201000-0002810.1227/00006123-199201000-00028 ↗
35. 10.1038/nature1649210.1038/nature16492 ↗
36. Listed N. · Electroencephalogr. Clin. Neurophysiol., Suppl. · 1999 · 52 · 1
37. 10.1038/nn.278210.1038/nn.2782 ↗
38. 10.1016/B978-0-08-026250-5.50011-310.1016/B978-0-08-026250-5.50011-3 ↗
39. 10.1002/adfm.20120308810.1002/adfm.201203088 ↗
40. 10.1002/adfm.20130184710.1002/adfm.201301847 ↗