journal article·2020-10

Continuous Heart Volume Monitoring by Fully Implantable Soft Strain Sensor

Seraina A. Dual, Byron Llerena Zambrano, Simon Sündermann, Nikola Cesarovic, Mareike Kron, Konstantinos Magkoutas, Julian Hengsteler, Volkmar Falk, Christoph Starck, Mirko Meboldt, János Vörös, Marianne Schmid Daners

Advanced Healthcare Materials· Volume 9· Issue 19
Publisher page

Abstract

Abstract Cardiothoracic open‐heart surgery has revolutionized the treatment of cardiovascular disease, the leading cause of death worldwide. After the surgery, hemodynamic and volume management can be complicated, for example in case of vasoplegia after endocarditis. Timely treatment is crucial for outcomes. Currently, treatment decisions are made based on heart volume, which needs to be measured manually by the clinician each time using ultrasound. Alternatively, implantable sensors offer a real‐time window into the dynamic function of our body. Here it is shown that a soft flexible sensor, made with biocompatible materials, implanted on the surface of the heart, can provide continuous information of the heart volume after surgery. The sensor works robustly for a period of two days on a tensile machine. The accuracy of measuring heart volume is improved compared to the clinical gold standard in vivo, with an error of 7.1 mL for the strain sensor versus impedance and 14.0 mL versus ultrasound. Implanting such a sensor would provide essential, continuous information on heart volume in the critical time following the surgery, allowing early identification of complications, facilitating treatment, and hence potentially improving patient outcome.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Mechanical Circulatory Support Devices · Cardiac Structural Anomalies and Repair · Congenital Heart Disease Studies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Product Development Group Zurich ETH Zurich Tannenstrasse 3 Zurich 8092 Switzerland

Cardiothoracic Surgery Stanford University Stanford CA 94305‐5101 USA

Laboratory of Biosensors and Bioelectronics ETH Zurich Gloriastrasse 35 Zurich 8092 Switzerland

DZHK (German Center for Cardiovascular Research) Partner Site Berlin 10785 Berlin Germany

Department of Cardiovascular Surgery Charité—Universitätsmedizin Berlin Charitéplatz 1 10117 Berlin Germany

Department of Cardiothoracic and Vascular Surgery German Heart Center Berlin Augustenburger Pl. 1 13353 Berlin Germany

Department of Health Sciences and Technology Tannenstrasse 3 Zürich 8092 Switzerland

Division for Surgical Research University Hospital Zurich and University of Zurich Rämistrasse 100 Zürich 8091 Switzerland

Funding

Georg und Bertha Schwyzer-Winiker Foundation · IMG Foundation · ETH Zurich Foundation and SENESCYT

References (50)

Show source-provided references
1. 10.1177/021849231037006010.1177/0218492310370060 ↗
2. 10.1111/j.0886-0440.2004.04101.x10.1111/j.0886-0440.2004.04101.x ↗
3. 10.1186/s13054-020-2743-810.1186/s13054-020-2743-8 ↗
4. 10.1053/j.semtcvs.2010.09.00710.1053/j.semtcvs.2010.09.007 ↗
5. 10.1053/j.jvca.2017.10.03210.1053/j.jvca.2017.10.032 ↗
6. 10.1186/s12871-018-0645-y10.1186/s12871-018-0645-y ↗
7. G. A.Schmidt JessMandel.Evaluation and management of suspected sepsis and septic shock in adults. In Geraldine Finlay MD (Ed.) UpToDate. Retrieved July 1 2020 fromhttps://www.uptodate.com/contents/evaluation-and-management-of-suspected-sepsis-and-septic-shock-in-adults.
8. 10.1053/j.jvca.2017.10.03210.1053/j.jvca.2017.10.032 ↗
9. 10.1016/j.jacc.2012.01.03710.1016/j.jacc.2012.01.037 ↗
10. 10.1016/j.jtcvs.2012.12.04810.1016/j.jtcvs.2012.12.048 ↗
11. 10.1161/01.CIR.70.5.81210.1161/01.CIR.70.5.812 ↗
12. 10.1097/MAT.000000000000053310.1097/MAT.0000000000000533 ↗
13. 10.1054/jcaf.2002.3237310.1054/jcaf.2002.32373 ↗
14. 10.1097/MAT.000000000000047710.1097/MAT.0000000000000477 ↗
15. 10.1016/j.jacc.2007.06.06110.1016/j.jacc.2007.06.061 ↗
16. 10.1002/admt.20180003110.1002/admt.201800031 ↗
17. 10.1038/nmat428910.1038/nmat4289 ↗
18. 10.1126/science.120615710.1126/science.1206157 ↗
19. 10.1038/srep0607410.1038/srep06074 ↗
20. 10.1038/nature1652110.1038/nature16521 ↗
21. 10.1161/01.CIR.0000040594.96123.5510.1161/01.CIR.0000040594.96123.55 ↗
22. Biocompatibility studies on silicone rubber
23. 10.1002/adma.20170652010.1002/adma.201706520 ↗
24. 10.1021/nn501204t10.1021/nn501204t ↗
25. 10.1021/acsnano.8b0540610.1021/acsnano.8b05406 ↗
26. 10.1002/aisy.20200003910.1002/aisy.202000039 ↗
27. 10.1111/aor.1337910.1111/aor.13379 ↗
28. 10.1115/1.404196610.1115/1.4041966 ↗
29. 10.1016/j.jacep.2017.11.00610.1016/j.jacep.2017.11.006 ↗
30. 10.1016/j.athoracsur.2003.08.05110.1016/j.athoracsur.2003.08.051 ↗
31. 10.1038/s41551-019-0440-110.1038/s41551-019-0440-1 ↗
32. 10.1038/s41586-019-1710-510.1038/s41586-019-1710-5 ↗
33. 10.1161/01.RES.62.6.124710.1161/01.RES.62.6.1247 ↗
34. 10.1038/ncomms432910.1038/ncomms4329 ↗
35. 10.1097/MAT.000000000000081810.1097/MAT.0000000000000818 ↗
36. 10.1016/j.hrthm.2017.06.00510.1016/j.hrthm.2017.06.005 ↗
37. 10.1109/TBME.2007.90353110.1109/TBME.2007.903531 ↗
38. 10.1126/scitranslmed.aaf392510.1126/scitranslmed.aaf3925 ↗
39. 10.1111/j.1525-1594.2011.01219.x10.1111/j.1525-1594.2011.01219.x ↗
40. 10.1038/s41565-018-0226-810.1038/s41565-018-0226-8 ↗
41. 10.1016/j.echo.2009.10.00410.1016/j.echo.2009.10.004 ↗
42. 10.1016/j.healun.2017.06.01710.1016/j.healun.2017.06.017 ↗
43. 10.1007/s10439-017-1858-910.1007/s10439-017-1858-9 ↗
44. 10.1111/aor.1299910.1111/aor.12999 ↗
45. 10.3389/fphys.2018.0052010.3389/fphys.2018.00520 ↗
46. S. A.Dual Measurement Principles for a Real‐Time Cardiac Volume Sensor Diss. ETH No. 25665 ETH Zurich 2019.
47. 10.1002/smll.20150284910.1002/smll.201502849 ↗
48. 10.5254/1.354266310.5254/1.3542663 ↗
49. 10.1109/TBME.2015.245768110.1109/TBME.2015.2457681 ↗
50. 10.1111/aor.1352110.1111/aor.13521 ↗