journal article·2015-01

Small‐Dose‐Sensitive X‐Ray Image Pixel with HgI2 Photoconductor and Amorphous Oxide Thin‐Film Transistor

Jae Chul Park, Pyo Jin Jeon, Jin Sung Kim, Seongil Im

Advanced Healthcare Materials· Volume 4· Issue 1
Publisher page

Abstract

A new X-ray image sensor is demonstrated with an oxide thin-film transistor backplane and HgI2 sensing material. It displays outstanding image quality under a low X-ray exposure and a low electric field. It is promising as a state-of-the-art device to realize highly resolved images at a low X-ray dose for a variety of medical X-ray imaging applications. As a service to our authors and readers, this journal provides supporting information supplied by the authors. Such materials are peer reviewed and may be re-organized for online delivery, but are not copy-edited or typeset. Technical support issues arising from supporting information (other than missing files) should be addressed to the authors. Please note: The publisher is not responsible for the content or functionality of any supporting information supplied by the authors. Any queries (other than missing content) should be directed to the corresponding author for the article.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: CCD and CMOS Imaging Sensors · Thin-Film Transistor Technologies · Electronic and Structural Properties of Oxides

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Institute of Physics and Applied Physics Yonsei University 262 Seongsanno Seodaemun‐gu, Seoul 120–749 Korea

References (34)

Show source-provided references
1. 10.1557/PROC-192-44110.1557/PROC-192-441 ↗
2. 10.1117/12.4343410.1117/12.43434 ↗
3. 10.1002/adma.20130180210.1002/adma.201301802 ↗
4. 10.1002/adhm.20120043610.1002/adhm.201200436 ↗
5. 10.1117/12.53401010.1117/12.534010 ↗
6. 10.1118/1.141351610.1118/1.1413516 ↗
7. 10.1118/1.156128510.1118/1.1561285 ↗
8. 10.1118/1.144987410.1118/1.1449874 ↗
9. 10.1118/1.153823310.1118/1.1538233 ↗
10. 10.1118/1.170775510.1118/1.1707755 ↗
11. 10.1109/TED.2008.92674410.1109/TED.2008.926744 ↗
12. Taghibakhsh F. · IEDM Tech. Dig. · 2007 · 1011
13. 10.1109/TNS.2005.85679010.1109/TNS.2005.856790 ↗
14. 10.1063/1.143629810.1063/1.1436298 ↗
15. 10.1117/12.38451110.1117/12.384511 ↗
16. 10.1038/nature0309010.1038/nature03090 ↗
17. 10.1002/adma.20080147010.1002/adma.200801470 ↗
18. 10.1002/adma.20100239710.1002/adma.201002397 ↗
19. 10.1109/TNS.2006.87704310.1109/TNS.2006.877043 ↗
20. 10.1088/0031-9155/58/3/70310.1088/0031-9155/58/3/703 ↗
21. 10.1109/TNS.2003.81454410.1109/TNS.2003.814544 ↗
22. 10.1063/1.145421310.1063/1.1454213 ↗
23. 10.1117/12.46558410.1117/12.465584 ↗
24. 10.1016/j.jnoncrysol.2005.11.08610.1016/j.jnoncrysol.2005.11.086 ↗
25. 10.1016/j.jnoncrysol.2007.09.04610.1016/j.jnoncrysol.2007.09.046 ↗
26. 10.1063/1.317381810.1063/1.3173818 ↗
27. 10.1088/0031-9155/53/5/01110.1088/0031-9155/53/5/011 ↗
28. IEC 62220–1–2 (2007) Medical electrical equipment – characteristics of digital X‐ray imaging devices: Part 1–2. Determination of the detective quantum efficiency – detectors used in mammography International Electrotechnical Commission (IEC) Geneva Switzerland.
29. 10.1063/1.36658610.1063/1.366586 ↗
30. 10.1063/1.36087310.1063/1.360873 ↗
31. 10.1063/1.140441810.1063/1.1404418 ↗
32. 10.1063/1.142338910.1063/1.1423389 ↗
33. 10.1109/LED.2009.202354310.1109/LED.2009.2023543 ↗
34. 10.1063/1.349155310.1063/1.3491553 ↗