Source abstract
Abstract
Abstract Microelectrode devices, which enable the detection of neuronal signals in brain tissues, have made significant contributions in the field of neuroscience and the brain–machine interfaces. To further develop such microelectrode devices, the following requirements must be met: i) a fine needle's diameter (<30 µm) to reduce damage to tissues; ii) a long needle (e.g., ≈1 mm for rodents and ≈2 mm for macaques); and iii) multiple electrodes to achieve high spatial recording (<100 µm in pitch). In order to meet these requirements, this study herein reports an assembly technique for high‐aspect‐ratio microneedles, which employs a magnet. The assembly is demonstrated, in which nickel wires of length 750 µm and diameter 25 µm are produced on a silicon substrate. The impedance magnitude of the assembled needle‐like electrode measured at 1 kHz is 5.6 kΩ, exhibiting output and input signal amplitudes of 96.7% at 1 kHz. To confirm the recording capability of the fabricated device, neuronal signal recordings are performed using mouse cerebra in vivo. The packaged single microneedle electrode penetrates the barrel field in the primary somatosensory cortex of the mouse and enables the detection of evoked neuronal activity of both local field potentials and action potentials.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Neuroscience and Neural Engineering · EEG and Brain-Computer Interfaces · Neural dynamics and brain function
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Electrical and Electronic Information Engineering Toyohashi University of Technology 1‐1 Hibarigaoka Tempaku‐cho Toyohashi 441–8580 Japan
National Institute of Advanced Industrial Science and Technology (AIST) 1‐1‐1 Umezono Tsukuba Ibaraki 305–8560 Japan
Electronics‐Interdisciplinary Research Institute (EIIRIS) Toyohashi University of Technology 1‐1 Hibarigaoka Tempaku‐cho Toyohashi 441–8580 Japan
Department of Environmental and Life Sciences Toyohashi University of Technology 1‐1 Hibarigaoka Tempaku‐cho Toyohashi 441–8580 Japan
Department of Computer Science and Engineering Toyohashi University of Technology 1‐1 Hibarigaoka Tempaku‐cho Toyohashi 441–8580 Japan
Funding
New Energy and Industrial Technology Development Organization · Takeda Science Foundation · Toyota Physical and Chemical Research Institute
References (24)
Show source-provided references
10. DeFelipe J. · Front. Neuroanat. · 2011 · 5 · 1
20. Fujishiro A. · Sci. Rep. · 2014 · 4 · 1