Divanadium Pentoxide Nanorods
Source abstract
Abstract
The reverse micelle technique, here used to synthesize divanadium pentoxide nanorods, enables the nanorod length to be tuned easily by simply keeping them in the micellar solution after the synthesis. The nanorods are characterized by transmission electron microscopy, X‐ray photoemission spectroscopy, and X‐ray diffraction. These techniques show that the nanorods are made of divanadium pentoxide with the structure of γ‐V2O5.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Transition Metal Oxide Nanomaterials · Copper-based nanomaterials and applications · Catalysis and Oxidation Reactions
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (19)
Show source-provided references
1. 10.1039/b100521i10.1039/b100521i ↗
2. 10.1002/1521-4095(20020805)14:15<1084::AID-ADMA1084>3.0.CO;2-L10.1002/1521-4095(20020805)14:15<1084::AID-ADMA1084>3.0.CO;2-L ↗
3. 10.1126/science.106654110.1126/science.1066541 ↗
4. 10.1021/jp961703z10.1021/jp961703z ↗
5. 10.1126/science.106081010.1126/science.1060810 ↗
6. 10.1021/nl015559r10.1021/nl015559r ↗
7. 10.1002/1521-4095(200102)13:4<261::AID-ADMA261>3.0.CO;2-X10.1002/1521-4095(200102)13:4<261::AID-ADMA261>3.0.CO;2-X ↗
8. 10.1021/nl010052210.1021/nl0100522 ↗
9. 10.1126/science.105849510.1126/science.1058495 ↗
10. Li M. · Nature · 1999 · 402 · 293
11. C. D. Wagner W. M. Riggs L. E. Davis J. F. Moulder Handbook of X‐ray Photoelectron Spectroscopy 1st ed. (Ed: G. E. Muilenberg) Perkin‐Elmer Corporation (Physical Electronics) Wellesley MA1979.
12. 10.1103/PhysRevB.20.154610.1103/PhysRevB.20.1546 ↗
13. Our assumption for normalization was that the main source of carbon in the nanorods spectra was due to residual AOT. After Shirley background subtraction we normalized the spectra of the nanorods and AOT relative to the integral under the C 1s peak. To check our assumption we normalized the two spectra relative to the integral under the S 2p peak too. We obtained the same result with both normalization procedures.
14. 10.1021/cm00016a00610.1021/cm00016a006 ↗
15. X‐ray diffraction patterns were measured with a Guinier powder diffractometer (Huber) using Cu Kα1pure monochromatic radiation in 45° transmission [17]. The patterns were corrected for background scattering and the usual angular factors.
16. 10.1016/0022-4596(91)90323-A10.1016/0022-4596(91)90323-A ↗
17. 10.1002/(SICI)1521-4079(199810)33:7/8<1141::AID-CRAT1141>3.0.CO;2-#10.1002/(SICI)1521-4079(199810)33:7/8<1141::AID-CRAT1141>3.0.CO;2-# ↗
18. N. Pinna M. Willinger J. Urban R. Schlögl unpublished.
19. 10.1021/la960319q10.1021/la960319q ↗