High-Speed, 3D Volumetric Displacement and Strain Mapping in Soft Materials Using Light Field Microscopy
Source abstract
Abstract
Background High strain-rate deformations of soft materials occur in many applications, and thus measurements of at-rate volumetric deformations are needed to understand physical processes relevant to, for example, hydrogel mechanics or injury biomechanics. Experimentally obtaining volumetric information and applying these techniques at high rates remains a significant challenge, especially at small, micrometer length scales. Methods To conduct 3D volumetric imaging at high rates, 100 frames per second (fps) to 10 kfps, we designed a full-field volumetric light field microscopy system paired with a high speed camera and custom particle tracking algorithm. Light field microscopy uses limited-angle tomographic volume reconstruction to obtain fully 3D data from a single 2D image. Simulated and experimental light-field images of particles at assorted strain-rates or frame-rates were created and used as verification and validation. These were used to investigate the sensitivity of the measurement technique to noise and obtain baseline displacement and strain uncertainty bounds for various motion fields. Reconstructed volumes from light field images were post-processed with volumetric particle tracking to quantify 3D volumetric deformations. As an experimental test case a transparent hydrogel seeded with fluorescent particles was deformed in a stage-top device. This custom-built device was programmed to deformed the specimen in nominally simple shear at applied strain rates between 2 s(-1) and 40 s(-1), while light-field images were collected at between 500 fps and 2000 fps. Results The synthetic and experimental images were used to compare known and reconstructed deformations. This showed that the acceptable imaging signal to noise ratio floor is approximately 10:1, which occurs at around 4000 fps as configured. Rigid body displacements up to 40 (mu)m in-plane and 400 (mu)m out-of-plane were tracked with standard errors less than approximately ±1.0 (mu)m and ±3.0 (mu)m, respectively. Synthetic large-motion uniaxial tension, rotation, and shear tests demonstrated total mean error less than 3 % engineering strain. The stage-top impact device demonstration showed that the in-vitro simple shear impact device applied a uniform strain to the specimen, while revealing a small amount of overshoot error and misalignment, demonstrating the diagnostic capability of this method for device calibration experiments. Conclusion We demonstrate a full-field volumetric light-field microscopy system paired with post-processing and particle tracking to quantify volumetric displacement and strain fields in soft, transparent materials undergoing high rate deformations.
Source: expertdata · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Optical measurement and interference techniques · Digital Holography and Microscopy · Advanced Fluorescence Microscopy Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (52)
Show source-provided references
1. Bay BK, Smith TS, Fyhrie DP, Saad M (1999) Digital volume correlation: Three-dimensional strain mapping using X-ray tomography. Exp Mech 39(3):217–226. https://doi.org/10.1007/BF0232355510.1007/BF02323555 ↗
2. Neu CP, Hull ML, Walton JH, Buonocore MH (2005) MRI-based technique for determining nonuniform deformations throughout the volume of articular cartilage explants. Magn Reson Med 53(2):321–328. https://doi.org/10.1002/mrm.2034310.1002/mrm.20343 ↗
3. Fu J, Pierron F, Ruiz PD (2013) lastic stiffness characterization using three-dimensional full-field deformation obtained with optical coherence tomography and digital volume correlation. J Biomed Opt 18(12):121512. https://doi.org/10.1117/1.JBO.18.12.12151210.1117/1.JBO.18.12.121512 ↗
4. Franck C, Hong S, Maskarinec SA, Tirrell DA, Ravichandran G (2007) Three-dimensional full-field measurements of large deformations in soft materials using confocal microscopy and digital volume correlation. Exp Mech 47(3):427–438. https://doi.org/10.1007/s11340-007-9037-910.1007/s11340-007-9037-9 ↗
5. Hoover EE, Squier JA (2013) Advances in multiphoton microscopy technology. Nat Photonics 7(2):93–101. https://doi.org/10.1038/nphoton.2012.36110.1038/nphoton.2012.361 ↗
6. Chatterjee K, Chatterjee K, Chatterjee K, Pratiwi FW, Pratiwi FW, Pratiwi FW, Wu FCM, Chen P, Chen BC (2018) Recent progress in light sheet microscopy for biological applications. Appl Spectrosc 72(8):1137–116910.1177/0003702818778851 ↗
7. Brown GM (2000) Overview of three-dimensional shape measurement using optical methods. Opt Eng 39(1):10. https://doi.org/10.1117/1.60243810.1117/1.602438 ↗
8. Mertz J (2019) Strategies for volumetric imaging with a fluorescence microscope. Optica 6(10):1261–1268. https://doi.org/10.1364/OPTICA.6.00126110.1364/OPTICA.6.001261 ↗
9. Copeland CR, McGray CD, Ilic BR, Geist J, Stavis SM (2021) Accurate localization microscopy by intrinsic aberration calibration. Nat Commun 12(1):3925. https://doi.org/10.1038/s41467-021-23419-y10.1038/s41467-021-23419-y ↗
10. Ren J, Han KY (2021) 2.5D microscopy: Fast, high-throughput imaging via volumetric projection for quantitative subcellular analysis. ACS Photonics 8(3):933–942. https://doi.org/10.1021/acsphotonics.1c0001210.1021/acsphotonics.1c00012 ↗
11. Abrahamsson S, McQuilken M, Mehta SB, Verma A, Larsch J, Ilic R, Heintzmann R, Bargmann CI, Gladfelter AS, Oldenbourg R (2015) MultiFocus Polarization Microscope (MF-PolScope) for 3D polarization imaging of up to 25 focal planes simultaneously. Opt Express 23(6):7734–7754. https://doi.org/10.1364/OE.23.00773410.1364/OE.23.007734 ↗
12. Abrahamsson S, Ilic R, Wisniewski J, Mehl B, Yu L, Chen L, Davanco M, Oudjedi L, Fiche JB, Hajj B, Jin X, Pulupa J, Cho C, Mir M, Beheiry ME, Darzacq X, Nollmann M, Dahan M, Wu C, Lionnet T, Liddle JA, Bargmann CI (2016) Multifocus microscopy with precise color multi-phase diffractive optics applied in functional neuronal imaging. Biomed Opt Express 7(3):855–869. https://doi.org/10.1364/BOE.7.00085510.1364/BOE.7.000855 ↗
13. Shi W, Dong P, Kuss MA, Gu L, Kievit F, Kim HJ, Duan B (2021) Design and evaluation of an in vitro mild traumatic brain injury modeling system using 3D printed mini impact device on the 3D cultured human iPSC derived neural progenitor cells. Adv Healthcare Mater 2100180. https://doi.org/10.1002/adhm.20210018010.1002/adhm.202100180 ↗
14. Estrada JB, Cramer HC, Scimone MT, Buyukozturk S, Franck C (2021) Neural cell injury pathology due to high-rate mechanical loading. Brain Multiphysics 2:100034. https://doi.org/10.1016/j.brain.2021.10003410.1016/j.brain.2021.100034 ↗
15. Levoy M, Ng R, Adams A, Footer M, Horowitz M (2006) Light field microscopy. In: ACM SIGGRAPH 2006 Papers on - SIGGRAPH ’06. ACM Press, Boston, Massachusetts, p 924. https://doi.org/10.1145/1179352.114197610.1145/1179352.1141976 ↗
16. Li H, Guo C, Kim-Holzapfel D, Li W, Altshuller Y, Schroeder B, Liu W, Meng Y, French JB, Takamaru KI, Frohman MA, Jia S (2019) Fast, volumetric live-cell imaging using high-resolution light-field microscopy. Biomed Opt Express 10(1):29–49. https://doi.org/10.1364/BOE.10.00002910.1364/BOE.10.000029 ↗
17. Broxton M, Grosenick L, Yang S, Cohen N, Andalman A, Deisseroth K, Levoy M (2013) Wave optics theory and 3-D deconvolution for the light field microscope. Opt Express 21(21):25418. https://doi.org/10.1364/OE.21.02541810.1364/OE.21.025418 ↗
18. Martínez-Corral M, Javidi B (2018) Fundamentals of 3D imaging and displays: a tutorial on integral imaging, light-field, and plenoptic systems. Adv Opt Photonics 10(3):512. https://doi.org/10.1364/AOP.10.00051210.1364/AOP.10.000512 ↗
19. Park JH, Hong K, Lee B (2009) Recent progress in three-dimensional information processing based on integral imaging. Appl Opt 48(34):H77–H94. https://doi.org/10.1364/AO.48.000H7710.1364/AO.48.000H77 ↗
20. Wu G, Masia B, Jarabo A, Zhang Y, Wang L, Dai Q, Chai T, Liu Y (2017) Light field image processing: An overview. IEEE J Sel Top Sign Proces 11(7):926–954. https://doi.org/10.1109/JSTSP.2017.274712610.1109/JSTSP.2017.2747126 ↗
21. Anglin P, Reeves SJ, Thurow BS (2017) Characterization of plenoptic imaging systems and efficient volumetric estimation from plenoptic data. IEEE J Sel Top Sign Proces 11(7):1020–1033. https://doi.org/10.1109/JSTSP.2017.274748110.1109/JSTSP.2017.2747481 ↗
22. Prevedel R, Yoon YG, Hoffmann M, Pak N, Wetzstein G, Kato S, Schrödel T, Raskar R, Zimmer M, Boyden ES, Vaziri A (2014) Simultaneous whole-animal 3D imaging of neuronal activity using light-field microscopy. Nat Methods 11(7):727–730. https://doi.org/10.1038/nmeth.296410.1038/nmeth.2964 ↗
23. Li H, Guo C, Jia S (2017) Frontiers in optics. In: Frontiers in Optics 2017 (2017), paper FW6D.3. Optical Society of America, p FW6D.3. https://doi.org/10.1364/FIO.2017.FW6D.310.1364/FIO.2017.FW6D.3 ↗
24. Pégard NC, Liu HY, Antipa N, Gerlock M, Adesnik H, Waller L (2016) Compressive light-field microscopy for 3D neural activity recording. Optica 3(5):517–524. https://doi.org/10.1364/OPTICA.3.00051710.1364/OPTICA.3.000517 ↗
25. Skocek O, Nöbauer T, Weilguny L, Martínez Traub F, Xia CN, Molodtsov MI, Grama A, Yamagata M, Aharoni D, Cox DD, Golshani P, Vaziri A (2018) High-speed volumetric imaging of neuronal activity in freely moving rodents. Nat Methods 15(6):429–432. https://doi.org/10.1038/s41592-018-0008-010.1038/s41592-018-0008-0 ↗
26. Kim J, Jung JH, Jeong Y, Hong K, Lee B (2014) Real-time integral imaging system for light field microscopy. Opt Express 22(9):10210. https://doi.org/10.1364/OE.22.01021010.1364/OE.22.010210 ↗
27. Ouellette NT, Xu H, Bodenschatz E (2006) A quantitative study of three-dimensional Lagrangian particle tracking algorithms. Exp Fluids 40(2):301–313. https://doi.org/10.1007/s00348-005-0068-710.1007/s00348-005-0068-7 ↗
28. Kim H, Westerweel J, Elsinga GE (2012) Comparison of Tomo-PIV and 3D-PTV for microfluidic flows. Meas Sci Technol 24(2)10.1088/0957-0233/24/2/024007 ↗
29. Elsinga GE, Scarano F, Wieneke B, van Oudheusden BW (2006) Tomographic particle image velocimetry. Exp Fluids 41(6):933–947. https://doi.org/10.1007/s00348-006-0212-z10.1007/s00348-006-0212-z ↗
30. Bajpayee A, Techet AH (2017) Fast volume reconstruction for 3D PIV. Exp Fluids 58(8):95. https://doi.org/10.1007/s00348-017-2373-310.1007/s00348-017-2373-3 ↗
31. Lynch K (2011) Development of a 3D fluid velocimetry technique based on light field imaging. Ph.D. thesis, Auburn University, Auburn, Alabama
32. Truscott TT, Belden J, Ni R, Pendlebury J, McEwen B (2017) Three-dimensional microscopic light field particle image velocimetry. Exp Fluids 58:16. https://doi.org/10.1007/s00348-016-2297-310.1007/s00348-016-2297-3 ↗
33. Pan Z, Lu M, Xia S (2019) Diffraction-assisted light field microscopy for microtomography and digital volume correlation with improved spatial resolution. Exp Mech 59(5):713–724. https://doi.org/10.1007/s11340-019-00522-210.1007/s11340-019-00522-2 ↗
34. Estrada JB, Barajas C, Henann DL, Johnsen E, Franck C (2018) High strain-rate soft material characterization via inertial cavitation. J Mech Phys Solids 112:291–317. https://doi.org/10.1016/j.jmps.2017.12.00610.1016/j.jmps.2017.12.006 ↗
35. Zou H, Schmiedeler JP, Hardy WN (2007) Separating brain motion into rigid body displacement and deformation under low-severity impacts. J Biomech 40(6):1183–1191. https://doi.org/10.1016/j.jbiomech.2006.06.01810.1016/j.jbiomech.2006.06.018 ↗
36. Sabet AA, Christoforou E, Zatlin B, Genin GM, Bayly PV (2008) Deformation of the human brain induced by mild angular head acceleration. J Biomech 41(2):307–315. https://doi.org/10.1016/j.jbiomech.2007.09.01610.1016/j.jbiomech.2007.09.016 ↗
37. Schreier H, Orteu JJ, Sutton MA (2009) Image correlation for shape, motion and deformation measurements. Springer, US10.1007/978-0-387-78747-3 ↗
38. Bar-Kochba E, Toyjanova J, Andrews E, Kim KS, Franck C (2015) A fast iterative digital volume correlation algorithm for large deformations. Exp Mech 55(1):261–274. https://doi.org/10.1007/s11340-014-9874-210.1007/s11340-014-9874-2 ↗
39. Patel M, Leggett SE, Landauer AK, Wong IY, Franck C (2018). Rapid, topology-based particle tracking for high-resolution measurements of large complex 3D motion fields. Sci Rep 8(1). https://doi.org/10.1038/s41598-018-23488-y10.1038/s41598-018-23488-y ↗
40. Hazlett L, Landauer AK, Patel M, Witt HA, Yang J, Reichner JS, Franck C (2020) Epifluorescence-based three-dimensional traction force microscopy. Sci Rep 10(1):1–1210.1038/s41598-020-72931-6 ↗
41. Yang J, Yin Y, Landauer AK, Buyuktozturk S, Zhang J, Summey L, McGhee A, Fu MK, Dabiri JO, Franck C (2022) Serialtrack: scale and rotation invariant augmented lagrangian particle tracking. https://doi.org/10.48550/ARXIV.2203.1257310.48550/ARXIV.2203.12573 ↗
42. Scimone MT, Cramer HC III, Bar-Kochba E, Amezcua R, Estrada JB, Franck C (2018) Modular approach for resolving and mapping complex neural and other cellular structures and their associated deformation fields in three dimensions. Nat Protoc 13(12):3042–3064. https://doi.org/10.1038/s41596-018-0077-710.1038/s41596-018-0077-7 ↗
43. Stefanoiu A, Page J, Symvoulidis P, Westmeyer GG, Lasser T (2019) Artifact-free deconvolution in light field microscopy. Opt Express 27(22):31644–31666. https://doi.org/10.1364/OE.27.03164410.1364/OE.27.031644 ↗
44. Georgiev T, Intwala C (2006) Light field camera design for integral view photography. Adobe Technical Report. Citeseer
45. Adrian L, Adrian RJ, Westerweel J (2011) Particle image velocimetry. No. 30. Cambridge University Press
46. Knoll SG, Ali MY, Saif MTA (2014) A novel method for localizing reporter fluorescent beads near the cell culture surface for traction force microscopy. J Vis Exp JOVE 51873. https://doi.org/10.3791/5187310.3791/51873 ↗
47. Summey L (2020) Development of a simple shear impact device for evaluating cellular traumatic brain injury. Master’s thesis. University of Wisconsin - Madison, Madison, Wisconsin
48. Hyun K, Wilhelm M, Klein CO, Cho KS, Nam JG, Ahn KH, Lee SJ, Ewoldt RH, McKinley GH (2011) A review of nonlinear oscillatory shear tests: Analysis and application of large amplitude oscillatory shear (LAOS). Prog Polym Sci 36(12):1697–1753. https://doi.org/10.1016/j.progpolymsci.2011.02.00210.1016/j.progpolymsci.2011.02.002 ↗
49. Buyukozturk S, Landauer AK, Zhang J, Summey L, Angel C, Franck C (2022) High-speed, 3D volumetric displacement and strain mapping in soft materials using light field microscopy [data set]. University of Wisconsin-Madison. https://doi.org/10.21231/YQZY-7X9010.21231/YQZY-7X90 ↗
50. Liu SL, Li J, Zhang ZL, Wang ZG, Tian ZQ, Wang GP, Pang DW (2013) Fast and high-accuracy localization for three-dimensional single-particle tracking. Sci Rep 3(1):2462. https://doi.org/10.1038/srep0246210.1038/srep02462 ↗
51. Janke T, Schwarze R, Bauer K (2020) Part2Track: A MATLAB package for double frame and time resolved particle tracking velocimetry. SoftwareX 11:100413. https://doi.org/10.1016/j.softx.2020.10041310.1016/j.softx.2020.100413 ↗
52. Landauer AK, Patel M, Henann DL, Franck C (2018) A q-factor-based digital image correlation algorithm (qDIC) for resolving finite deformations with degenerate speckle patterns. Exp Mech 58(5):815–830. https://doi.org/10.1007/s11340-018-0377-410.1007/s11340-018-0377-4 ↗