Experimental Evaluation of Strain Shielding in Distal Femur in Revision TKA
Source abstract
Abstract
Theoretical concerns about the use of cemented and press-fit stems in revision total knee arthroplasty (TKA) include stress shielding with adverse effects on prosthesis fixation. Radiological studies have showed distal femoral bone resorption after revision TKA. The revision with use of stems can place abnormal stresses. These stresses can promote the effect of bone stress shielding and may contribute to bone loss. Experimental quantification of strain shielding in the distal synthetic femur following TKA is the main purpose of the present study. Three different constructs of TKA were assessed. The first construct included a stemless femoral component. The other two included a press-fit and a cemented femoral stem. Cortical bone strains were measured experimentally with tri-axial strain gauges in synthetic femurs before and after in-vitro knee surgery. The difference between principal strains of implanted and intact femur was calculated for each strain gauge position. This study indicates that the use of stems in distal femur changes the distribution and magnitude of bone strains. The press-fit stem provoked relevant bone area (stem length) subjected to strain shielding and also originated the highest reduction of strains in the distal region, which can potentially induce bone resorption. The stemless implanted femur produced minor bone strain changes relatively to the intact femur. The use of distal femur stems increases initial stability in the bone, but the observed reduction of strains in this region, relative to the intact femur, provokes strain shielding that can induce bone resorption and may compromise the long term implant stability.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Total Knee Arthroplasty Outcomes · Orthopaedic implants and arthroplasty · Orthopedic Infections and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (28)
Show source-provided references
1. AOANJRR (2006) Australian Orthopaedic Association National Joint Replacement Registry, Annual Report.
2. CJRR (2005) Total hip and total knee replacements in Canada. Annual Report.
3. SKAR (2005) The Swedish Knee Arthroplasty Register. Annual Report.
4. Whiteside LA (1993) Cementless revision total knee arthroplasty. Clin Orthop 286:160–167.
5. Windsor RE, Insall JN, Sculco TP (1986) Bone grafting of tibial defects in primary and revision total knee arthroplasty. Clin Orthop 205:132–137.10.1097/00003086-198604000-00016 ↗
6. van Loon CJ, Waal MC, Buma P, Verdonschot N, Veth RP (1999) Femoral bone loss in total knee arthroplasty. A review. Acta Orthop Belg 65:154–163.
7. Turner TM, Sumner DR, Urban RM, Igloria R, Galante JO (1997) Maintenance of proximal cortical bone with use of a less stiff femoral component in hemiarthroplasty of the hip without cement. An investigation in a canine model at six months and two years. J Bone Joint Surg Am 79:1381–1390.10.2106/00004623-199709000-00013 ↗
8. Angelides M, Chan K, Ahmed AM, Joly L (1988) Effect of total knee arthroplasty on distal femur stresses. Trans Orthop Res Soc 13:475.
9. Tissakht M, Chan K, Ahmed AM (1992) Bone remodeling in the distal femur with TKR: correlation with mechanical parameters. Trans Orthop Res Soc 17:321.
10. van Lenthe GH, Malefijt MCW, Huiskes R (1997) Stress shielding after total knee replacement may cause bone resorption in distal femur. J Bone Joint Surg Br 79-B:117–122.10.1302/0301-620X.79B1.0790117 ↗
11. van Lenthe GH, Willems MMM, Verdonschot N, Malefijt MCW, Huiskes R (2002) Stemmed femoral knee prostheses. Effects of prosthetic design and fixation on bone loss. Acta Orthop Scand 73:630–637.10.3109/17453670209178027 ↗
12. Mintzer CM, Robertson DD, Rackemann S (1990) Bone loss in the distal anterior femur after total knee arthroplasty. Clin Orthop 260:135–143.10.1097/00003086-199011000-00024 ↗
13. Bertin KC, Freeman MA, Samuelson KM, Ratcliffe SS, Todd RC (1985) Stemmed revision arthroplasty for aseptic loosening of total knee replacement. J Bone Joint Surg Br 67:242–248.10.1302/0301-620X.67B2.3980534 ↗
14. Haas SB, Insall JN, Montgomery W 3rd, Windsor RE (1995) Revision total knee arthroplasty with use of modular components with stems inserted without cement. J Bone Joint Surg Am 77:1700–1707.10.2106/00004623-199511000-00009 ↗
15. Bryan RS, Rand JA (1982) Revision total knee arthroplasty. Clin Orthop 170:116–122.10.1097/00003086-198210000-00015 ↗
16. Friedman RJ, Hirst P, Ross R, Kelley K, Sledge CB (1990) Results of revision total knee arthroplasty performed for aseptic loosening. Clin Orthop 255:235–241.10.1097/00003086-199006000-00031 ↗
17. Murray PB, Rand JA, Hanssen AD (1994) Cemented long-stem revision total knee arthroplasty. Clin Orthop 309:116–123.
18. Huiskes R, Weinans H, van Rietbergen B (1992) The relationship between stress shielding and bone resorption around total hip stems and the effect of flexible materials. Clin Orthop Relat Res 274:124–134.10.1097/00003086-199201000-00014 ↗
19. Crowninshield RD, Pedersen DR, Brand RA (1980) A measurement of proximal femur strain with total hip arthroplasty. J Biomech Eng 102:230–233.10.1115/1.3149578 ↗
20. Szivek JA, Gealer RL (1991) Comparison of the deformation response of synthetic and cadaveric femora during simulated one-legged stance. J Appl Biomater 24:277–280.10.1002/jab.770020410 ↗
21. Young-Hoo K, Kim JS, Cho SH (2001) Strain distribution in the proximal human femur. J Bone Joint Surg 83:295–301.
22. Cristofolini L, Viceconti M (1996) Mechanical validation of whole bone composite femur models. J Biomech 29:525–535.10.1016/0021-9290(95)00084-4 ↗
23. Heiner AD, Brown TD (2001) Structural properties of new design of composite replicate femurs and tibias. J Biomech 34:773–781.10.1016/S0021-9290(01)00015-X ↗
24. Completo A, Fonseca F, Simões J (2007) Experimental validation of intact and implanted distal femur finite element models. J Biomech 40:2467–2476.10.1016/j.jbiomech.2006.11.012 ↗
25. Morrison JB (1970) The mechanics of the knee joint in relation to normal walking. J Biomech 3:51–61.10.1016/0021-9290(70)90050-3 ↗
26. Karbowski A, Schwitalle M, Eckardt A, Heine J (1999) Periprosthetic bone remodelling after total knee arthroplasty: early assessment by dual energy X-ray absorptiometry. Arch Orthop Trauma Surg 119:324–326.10.1007/s004020050419 ↗
27. Petersen MM, Lauritzen JB, Pedersen JG, Lund B (1996) Decreased bone density of the distal femur after uncemented knee arthroplasty. A 1-year follow-up of 29 knees. Acta Orthop Scand 67:339–344.10.3109/17453679609002327 ↗
28. van Loon CJ, Oyen WJ, de Waal Malefijt MC, Verdonschot N (2001) Distal femoral bone mineral density after total knee arthroplasty: a comparison with general bone mineral density. Arch Orthop Trauma Surg 121:282–285.10.1007/s004020000232 ↗