journal article·2020-09

Self-adaptive flexible valve as passive flow regulator

Qiang Zhang, Xirui Peng, Shayuan Weng, Rundong Zhang, Daining Fang, Ruike Zhao, H. Jerry Qi

Publisher page

Abstract

Abstract Valves are widely used in fluidic channel systems to regulate flows. In many applications, maintaining a constant flow rate under varying input conditions is critical. However, current active or passive valves suffer from several drawbacks, such as complex structures, complicated fabrication processes, and complex operational procedures. This paper presents a novel design concept for fluidic channels using a simple structure that can serve as self-adaptive passive valves to regulate flow under external pressure. The design relies on embedding a cantilever-like flap inside a channel to provide a self-regulated closed-loop control of the flow. The flap can passively deform to adapt to the variation of the fluid pressure. A theoretical model is developed and validated by finite-element simulations to understand the flow characteristics of this design. Based on the theoretical model, we provide the design rules for obtaining valves with desired pressure-flow rate responses. Furthermore, by integrating the quantitative design tool and 3D printing, a valve that can maintain a constant flow rate over a certain pressure range is designed, fabricated, and characterized. With support from systematic analysis and rapid manufacturing techniques, the valve design proposed here can open routes for applications in microfluidic systems and drug infusion systems.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Microfluidic and Capillary Electrophoresis Applications · Advanced Sensor and Energy Harvesting Materials · Electrohydrodynamics and Fluid Dynamics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (44)

Show source-provided references
1. Silk fibroin microfluidic devices10.1002/adma.200602487 ↗
2. Wang · 2002 · 223
3. McDonald · 2000 · 27
4. Ten key issues in modern flow chemistry10.1039/c0cc05060a ↗
5. Continuous flow synthesis. A pharma perspective10.1021/jm2006029 ↗
6. Hard and soft micromachining for BioMEMS: review of techniques and examples of applications in microfluidics and drug delivery10.1016/j.addr.2003.09.001 ↗
7. Microneedle-array patches loaded with hypoxia-sensitive vesicles provide fast glucose-responsive insulin delivery10.1073/pnas.1505405112 ↗
8. Materials for diabetes therapeutics10.1002/adhm.201200037 ↗
9. Insulin-pump therapy for type 1 diabetes mellitus10.1056/NEJMct1113948 ↗
10. Overnight closed loop insulin delivery (artificial pancreas) in adults with type 1 diabetes: crossover randomised controlled studies10.1136/bmj.d1855 ↗
11. Goodnow · 2013
12. Piezoelectric micropump with three valves working peristaltically10.1016/0924-4247(90)85039-7 ↗
13. The piezoelectric valve-less pump—performance enhancement analysis10.1016/S0924-4247(98)00058-2 ↗
14. A latchable phase-change microvalve with integrated heaters10.1109/JMEMS.2009.2024806 ↗
15. PMMA/PDMS valves and pumps for disposable microfluidics10.1039/b907254c ↗
16. A microfluidic-based dynamic microarray system with single-layer pneumatic valves for immobilization and selective retrieval of single microbeads10.1007/s10404-013-1267-9 ↗
17. Single-layer membrane valves for elastomeric microfluidic devices10.1063/1.2945797 ↗
18. Microfluidic sorting with high-speed single-layer membrane valves10.1063/1.3431281 ↗
19. Integrated surface-micromachined mass flow controller
20. Independent optical control of microfluidic valves formed from optomechanically responsive nanocomposite hydrogels10.1002/adma.200401239 ↗
21. Design and characterization of a magnetic digital flow regulator10.1016/j.sna.2010.04.025 ↗
22. Magnetically triggered nanocomposite membranes: a versatile platform for triggered drug release10.1021/nl200494t ↗
23. Passive flow-rate regulators using pressure-dependent autonomous deflection of parallel membrane valves10.1039/b821524c ↗
24. Planar micro-check valves exploiting large polymer compliance10.1016/j.sna.2006.07.016 ↗
25. Microfluidic vias enable nested bioarrays and autoregulatory devices in Newtonian fluids10.1073/pnas.0602890103 ↗
26. Quantitative modeling of the behaviour of microfluidic autoregulatory devices10.1039/c2lc20956j ↗
27. Improved micro-flow regulator for drug delivery systems
28. Microfluidic memory and control devices10.1126/science.1083694 ↗
29. On the biomechanics of heart valve function10.1016/j.jbiomech.2009.05.015 ↗
30. A planar compliance-based self-adaptive microfluidvariable resistor10.1109/JMEMS.2007.892892 ↗
31. Passive flow regulator for precise high-throughput flow rate control in microfluidic environments10.1039/C6RA01093H ↗
32. A passive flow regulator with low threshold pressure for high-throughput inertial isolation of microbeads10.1039/C5LC00647C ↗
33. A microfluidic gas damper for stabilizing gas pressure in portable microfluidic systems10.1063/1.4966646 ↗
34. Flow stabilizer on a syringe tip for hand-powered microfluidic sample injection10.1039/C8LC01051J ↗
35. Gere · 1997
36. Munson · 2013
37. Direct 4d printing via active composite materials10.1126/sciadv.1602890 ↗
38. Non-overshooting PI control of variable-speed motor drives with sliding perturbation observers10.1016/j.mechatronics.2005.03.006 ↗
39. PI/PID controller design based on IMC and percentage overshoot specification to controller setpoint change10.1016/j.isatra.2008.09.002 ↗
40. 3D printed microfluidic devices with integrated valves10.1063/1.4905840 ↗
41. Customisable 3D printed microfluidics for integrated analysis and optimisation10.1039/C6LC00562D ↗
42. Moving from millifluidic to truly microfluidic sub-100-mum cross-section 3D printed devices10.1007/s00216-017-0398-3 ↗
43. Custom 3D printer and resin for 18 mum × 20 mum microfluidic flow channels10.1039/C7LC00644F ↗
44. Functional 3D printing for microfluidic chips10.1002/admt.201900275 ↗