journal article·2026-06-29

In Vivo Monitoring of Thrombo‐Inflammatory Biomarkers via Molecularly Imprinted Polymer‐Integrated Hydrogel Microneedles

Mahmoud Ayman Saleh, Peyman GhavamiNejad, Arash Khorrami Jahromi, Sanjana Srikant, Sripadh Guptha Yedire, Fatemeh Keyvani, Roozbeh Siavash Moakhar, Sajad Shiekh, Mackenzie Graham, Joe Quadrilatero, Mahla Poudineh, Sara Mahshid

Publisher page

Abstract

ABSTRACT Thrombotic disorders are a leading cause of cardiovascular mortality worldwide; however, real‐time, point‐of‐care monitoring technologies for timely detection of evolving coagulopathies remain inaccessible. Wearable, minimally invasive tracking of thrombo‐inflammatory activity could enable earlier risk assessment and more effective therapy monitoring than conventional episodic blood tests. Here, we present a reagent‐free, wearable electrochemical platform that integrates an on‐chip Prussian Blue (PB) redox transducer with a signal‐off molecularly imprinted polymer (MIP) layer and a biocompatible hydrogel microneedle (HMN) array for interstitial fluid (ISF) sampling, enabling direct electrochemical detection of thrombo‐inflammatory biomarkers. The electrochemical PB/MIP (e‐MIP) biosensor was configured to quantify thrombin (thrombotic biomarker) as well as interleukin‐6 (IL‐6) and tumor necrosis factor‐α (TNF‐α) (inflammatory biomarkers) directly in dermal ISF extracted via the integrated HMNs. The wearable e‐MIP was characterized in vitro and ex vivo, where porcine skin tests preserved linearity and achieved limits of detection (LODs) of 0.26 ng mL − 1 for thrombin and ≤ 0.41 pg mL − 1 for IL‐6 and TNF‐α, confirming sensitive performance in a skin model. Also, selectivity studies against potential interferents (e.g., prothrombin or cardiac troponins) were conducted to assess the possible cross‐reactivity. in vivo, HMN‐integrated patches applied to lipopolysaccharide (LPS)–challenged rats sampled ISF and delivered it to the e‐MIP, which captured the rise‐and‐fall kinetics of thrombin and IL‐6 over 0–24 h. The results were validated against parallel enzyme‐linked immunosorbent assays (ELISAs) performed on plasma collected at corresponding time points. Its versatile architecture and demonstrated in vivo performance position it as a promising platform that can enable early thrombotic risk assessment and therapeutic monitoring, with potential applications in personalized cardiovascular management following clinical validation.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Advancements in Transdermal Drug Delivery · Blood properties and coagulation · Advanced Sensor and Energy Harvesting Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Bioengineering McGill University Montreal Quebec Canada

Department of Electrical and Computer Engineering University of Waterloo Waterloo Canada

Waterloo Institute for Nanotechnology University of Waterloo Waterloo Ontario Canada

Department of Kinesiology and Health Sciences University of Waterloo Waterloo Ontario Canada

Division of Experimental Medicine McGill University Montreal Quebec Canada

Funding

Canada Foundation for Innovation · Natural Sciences and Engineering Research Council of Canada

References (65)

Show source-provided references
1. 10.1038/nature0679710.1038/nature06797 ↗
2. 10.1182/blood.V96.1.17010.1182/blood.V96.1.170 ↗
3. 10.1097/CCM.0B013E3181C98D2110.1097/CCM.0B013E3181C98D21 ↗
4. 10.1371/journal.pone.020551110.1371/journal.pone.0205511 ↗
5. 10.2147/IJGM.S37203810.2147/IJGM.S372038 ↗
6. 10.1038/srep3218810.1038/srep32188 ↗
7. 10.1038/s12276‐021‐00649‐010.1038/s12276‐021‐00649‐0 ↗
8. 10.3390/LIFE1501004710.3390/LIFE15010047 ↗
9. 10.1161/ATVBAHA.111.22345310.1161/ATVBAHA.111.223453 ↗
10. Biomarker‐Based Prediction of Recurrent Ischemic Events in Patients With Acute Coronary Syndromes10.1016/j.jacc.2022.08.767 ↗
11. 10.1007/s00281‐011‐0281‐910.1007/s00281‐011‐0281‐9 ↗
12. Serum Soluble Interleukin 6 (IL‐6) Receptor and IL‐6/Soluble IL‐6 Receptor Complex in Systemic Juvenile Rheumatoid Arthritis10.1172/JCI117206 ↗
13. 10.3390/cells1411076610.3390/cells14110766 ↗
14. 10.3324/haematol.2020.25304710.3324/haematol.2020.253047 ↗
15. 10.71480/nmj.v66i2.84510.71480/nmj.v66i2.845 ↗
16. 10.1007/s10238‐016‐0417‐210.1007/s10238‐016‐0417‐2 ↗
17. 10.1186/s12959‐024‐00586‐810.1186/s12959‐024‐00586‐8 ↗
18. 10.1111/jth.126910.1111/jth.1269 ↗
19. 10.1126/science.adn260010.1126/science.adn2600 ↗
20. 10.1111/jth.1319110.1111/jth.13191 ↗
21. 10.1002/adma.20250041210.1002/adma.202500412 ↗
22. 10.1038/s41467‐025‐58147‐010.1038/s41467‐025‐58147‐0 ↗
23. 10.1038/s41467‐024‐44751‐z10.1038/s41467‐024‐44751‐z ↗
24. Integrated Electrochemical Aptamer Biosensing and Colorimetric pH Monitoring via Hydrogel Microneedle Assays for Assessing Antibiotic Treatment10.1002/advs.202309027 ↗
25. 10.1002/adma.20240200910.1002/adma.202402009 ↗
26. 10.1038/s43246‐024‐00468‐610.1038/s43246‐024‐00468‐6 ↗
27. 10.1038/s41551‐022‐00998‐910.1038/s41551‐022‐00998‐9 ↗
28. 10.1038/s41378‐022‐00443‐610.1038/s41378‐022‐00443‐6 ↗
29. Integrated Electrochemical Aptamer Biosensing and Colorimetric pH Monitoring via Hydrogel Microneedle Assays for Assessing Antibiotic Treatment10.1002/advs.202309027 ↗
30. Molecularly Imprinted Electrochemical Biosensor for Thrombin Detection by Comparing Different Monomers10.4155/bio-2023-0203 ↗
31. 10.3390/bios1505032010.3390/bios15050320 ↗
32. 10.1016/j.bios.2023.11571310.1016/j.bios.2023.115713 ↗
33. 10.1038/s41467‐024‐44751‐z10.1038/s41467‐024‐44751‐z ↗
34. Monolithic Cell‐on‐Memristor Architecture Enables Wafer‐Scale Integration of Oscillatory Chemoreceptors for Bio‐Realistic Gustatory Chips10.1038/s41563-025-02436-y ↗
35. 10.1038/s41467‐025‐58147‐010.1038/s41467‐025‐58147‐0 ↗
36. A Zero‐Voltage‐Writing Artificial Nervous System Based on Biosensor Integrated on Ferroelectric Tunnel Junction10.1002/adma.202404026 ↗
37. 10.1038/s41551‐022‐00916‐z10.1038/s41551‐022‐00916‐z ↗
38. 10.1126/SCIADV.ADF7388/SUPPL_FILE/SCIADV.ADF7388_MOVIE_S1.ZIP10.1126/SCIADV.ADF7388/SUPPL_FILE/SCIADV.ADF7388_MOVIE_S1.ZIP ↗
39. 10.1039/D3LC00210A10.1039/D3LC00210A ↗
40. 10.1038/s41551‐022‐00887‐110.1038/s41551‐022‐00887‐1 ↗
41. 10.1038/s41551‐020‐00672‐y10.1038/s41551‐020‐00672‐y ↗
42. 10.1016/j.trac.2007.12.00410.1016/j.trac.2007.12.004 ↗
43. 10.1038/nrd.2016.19910.1038/nrd.2016.199 ↗
44. 10.1021/cr068123a10.1021/cr068123a ↗
45. 10.1016/j.trac.2015.03.00610.1016/j.trac.2015.03.006 ↗
46. 10.1002/advs.20220424610.1002/advs.202204246 ↗
47. 10.1021/acssensors.0c0170110.1021/acssensors.0c01701 ↗
48. 10.1016/j.snb.2018.12.09110.1016/j.snb.2018.12.091 ↗
49. 10.3390/s1904080010.3390/s19040800 ↗
50. 10.1039/D4AN00247D10.1039/D4AN00247D ↗
51. 10.1002/adma.20231374310.1002/adma.202313743 ↗
52. 10.1055/s‐0043‐177585610.1055/s‐0043‐1775856 ↗
53. Electrosynthesized Molecularly Imprinted Polymers for Protein Recognition10.1016/j.trac.2015.12.018 ↗
54. 10.37678/dcybd.2023.348810.37678/dcybd.2023.3488 ↗
55. Lipopolysaccharide Treatment Reduces Rat Platelet Aggregation Independent of Intracellular Reactive‐Oxygen Species Generation10.3109/09537104.2011.603065 ↗
56. 10.1371/journal.pone.013790110.1371/journal.pone.0137901 ↗
57. 10.1038/s41551‐022‐00998‐910.1038/s41551‐022‐00998‐9 ↗
58. 10.1186/s13075‐015‐0575‐810.1186/s13075‐015‐0575‐8 ↗
59. 10.3389/fimmu.2020.59763210.3389/fimmu.2020.597632 ↗
60. 10.1371/journal.pone.014501210.1371/journal.pone.0145012 ↗
61. 10.1093/gerona/63.12.129910.1093/gerona/63.12.1299 ↗
62. 10.1113/jphysiol.2011.20613610.1113/jphysiol.2011.206136 ↗
63. 10.1021/acs.jcim.1c0020310.1021/acs.jcim.1c00203 ↗
64. 10.1002/jcc.2125610.1002/jcc.21256 ↗
65. 10.1186/1758‐2946‐4‐1710.1186/1758‐2946‐4‐17 ↗