PmP116. Studies on flaws in PZT ceramics used in underwater detection transducers
Source abstract
Abstract
Abstract Experiments on a piezoelectric Tonpilz power transducer show the importance of the quality of the ceramic active material. In order to determine if internal defects appear in PZT ceramics owing to the working of the transducer, two methods of investigation are proposed: an electrical one by measurement of the admittance versus frequency and an ultrasonic one. These two methods lead to identical results for eliminating defective ceramics.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Ultrasonics and Acoustic Wave Propagation · Engineering Applied Research · Flow Measurement and Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (5)
Show source-provided references
1. Boucher, D. 1988. 100–120. Berlin: Springer-Verlag. Proc. of Int. Workshop10.1007/978-3-642-73263-8_7 ↗
2. Amadei-Guillemot, M. M. 1990. Thèse, Acoustique, INSA Lyon
3. 10.1080/0015019890801733410.1080/00150198908017334 ↗
4. 10.1111/j.1151-2916.1979.tb12730.x10.1111/j.1151-2916.1979.tb12730.x ↗
5. Chiang S. · Com. Am. Ceram. Soc. · 1981 · 141