journal article·2024-11Open access

The evolution of reaction to fire classification of materials: A case study of Canada

Amirouche Sadaoui, Christian Dagenais, Pierre Blanchet, Cédric Perez

Fire and Materials· Volume 48· Issue 7

Abstract

Abstract Combustible and noncombustible notions have evolved with time, along with the associated fire tests by which legislation classifies building materials. New Zealand, Japan, and Europe are just some of the many legislations that have followed this evolution, except for North American regulations, which remain attached to methods dating back to 1944. To better understand this stagnation in North American practices, this document first traces the evolution of Canadian regulations on fire classification of materials. Then, a parallel is drawn with the evolution of reaction to fire tests mandated in the National Building Code of Canada. Finally, this paper will review the current fire classification of materials concerning the combustibility concept based on the Steiner tunnel test and the flame spread rating criteria. The analysis reveals that the relevance of the test and its results are questionable, and the reciprocity between test measurement and its classification does not always coincide. Despite the revisions made through time, the classification of materials based on their fire properties remains distinctly binary.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Fire dynamics and safety research · Fire effects on ecosystems · Fire effects on concrete materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

NSERC Industrial Research Chair on Eco‐Responsible Wood Construction (CIRCERB), Department of Wood and Forest Sciences Université Laval Quebec City Quebec Canada

Funding

Natural Sciences and Engineering Research Council of Canada

References (78)

Show source-provided references
1. 10.1016/B978‐0‐08‐102801‐8.00004‐110.1016/B978‐0‐08‐102801‐8.00004‐1 ↗
2. 10.1016/B978‐0‐08‐102801‐8.00092‐210.1016/B978‐0‐08‐102801‐8.00092‐2 ↗
3. 10.1016/B978‐0‐08‐102801‐8.00066‐110.1016/B978‐0‐08‐102801‐8.00066‐1 ↗
4. 10.1002/fam.308710.1002/fam.3087 ↗
5. 10.3210/fst.21.1910.3210/fst.21.19 ↗
6. Collier P · 2006
7. 10.1007/s00107‐006‐0116‐x10.1007/s00107‐006‐0116‐x ↗
8. 10.1007/s10694‐016‐0570‐x10.1007/s10694‐016‐0570‐x ↗
9. 10.1007/978‐1‐4939‐2565‐0_2710.1007/978‐1‐4939‐2565‐0_27 ↗
10. 10.1520/STP15553S10.1520/STP15553S ↗
11. Burning characteristics of building materials
12. National Research Council Of Canada.Associate committee on the National Building Code. National Building Code 1941. National Research Council of Canada1941. doi:10.4224/40001282
13. 10.1201/978100319031810.1201/9781003190318 ↗
14. EN 1999‐1‐2:2007.Eurocode 9: Design of Aluminium Structures – Part 1–2: Structural Fire Design.
15. National Research Council of Canada.Associate Committee on the National Building Code.National Building Code of Canada: 1953. National Research Council of Canada1953. doi:10.4224/40001291
16. National Research Council of Canada.Associate Committee on the National Building Code.National Building Code of Canada: 1960. National Research Council of Canada1963. doi:10.4224/40001400
17. National Research Council Of Canada.Associate Committee on the National Building Code.National Building Code of Canada: 1965(Third Printing). National Research Council of Canada1967. doi:10.4224/40001408
18. National Research Council Of Canada.Associate Committee on the National Building Code.National Building Code of Canada: 1970. National Research Council of Canada1971. doi:10.4224/40001705
19. National Research Council Of Canada.Associate Committee on the National Building Code.National Building Code of Canada: 1975. National Research Council of Canada1975. doi:10.4224/40001677
20. 10.4224/4000136410.4224/40001364 ↗
21. National Research Council Of Canada.Associate Committee on the National Building Code.National Building Code of Canada: 1977. National Research Council of Canada1977. doi:10.4224/40001638
22. 10.4224/2033809910.4224/20338099 ↗
23. D'SouzaMV McGuireJH.ASTM E‐84 and the Flammability of Foamed Thermosetting Plastics.Paper(National Research Council of Canada. Division of Building Research); no. DBR‐P‐724.1977. doi:10.4224/4000176410.1007/BF02303053 ↗
24. ShorterGW McGuireJH.Fire and plastic foam insulation material.Canadian Building Digest no. CBD‐178.1976. doi:10.4224/40000754
25. National Research Council of Canada.Associate Committee on the National Building Code.National Building Code of Canada: 1980. National Research Council of Canada1981. doi:10.4224/40001489
26. National Research Council of Canada.Associate Committee on the National Building Code.National Building Code of Canada: 1985. National Research Council of Canada1986. doi:10.4224/40001248
27. 10.4224/2032841010.4224/20328410 ↗
28. National model construction codes
29. 10.4224/4000124510.4224/40001245 ↗
30. CAN/ULC‐S135 · 2022
31. 10.4224/w324‐hv9310.4224/w324‐hv93 ↗
32. National Research Council Of Canada.Associate Committee on the National Building Code.National Building Code of Canada: 1990. National Research Council of Canada1992. doi:10.4224/40001453
33. 10.4224/4000125210.4224/40001252 ↗
34. 10.4224/4000126810.4224/40001268 ↗
35. 10.4224/4000200510.4224/40002005 ↗
36. Prince RE · 1914
37. PrinceRE.Tests on the inflammability of untreated wood and wood treated with fire‐retarding compounds.National Fire Protection Association. Proc. 19th Ann. Meeting.1915:108–158.
38. SetchkinNP IngbergSH.Test criterion for an incombustible material. American Society for Testing and Materials. Proceedings 1945: Volume 451945:866–877.
39. 10.6028/NBS.RPT.145410.6028/NBS.RPT.1454 ↗
40. 10.4224/2038679910.4224/20386799 ↗
41. CAN/ULC‐S114 · 2018
42. ASTM E136.Test Method for Assessing Combustibility of Materials Using a Vertical Tube Furnace at 750C.2022. doi:10.1520/E0136‐2210.1520/E0136 ↗
43. ISO 1182.Reaction to fire tests for products — Non‐combustibility test.2010.
44. EN 13501–1:2018.Fire classification of construction products and building elements. Part 1: Classification using data from reaction to fire tests.
45. 10.6028/NBS.SP.74510.6028/NBS.SP.745 ↗
46. Babrauskas V · 1982
47. 10.1002/fam.81015030510.1002/fam.810150305 ↗
48. Babrauskas V · 1992 · 257
49. ISO 5660‐1:2002 · 2022
50. 10.1520/E1354‐2310.1520/E1354‐23 ↗
51. ISO 9705 · 1993
52. 10.1520/E2965‐22A10.1520/E2965‐22A ↗
53. 10.4224/2037593310.4224/20375933 ↗
54. 10.1080/1478644020863562710.1080/14786440208635627 ↗
55. 10.1002/fam.81004020210.1002/fam.810040202 ↗
56. 10.1023/A:101541600588810.1023/A:1015416005888 ↗
57. 10.1002/fam.78210.1002/fam.782 ↗
58. 10.1520/JTE10767J10.1520/JTE10767J ↗
59. CAN/ULC‐S102 · 2019
60. CAN/ULC‐S102.2 · 2019
61. 10.1520/E0084‐23C10.1520/E0084‐23C ↗
62. UL 723:2018 · 2018
63. NFPA 255.Standard method of test of surface burning characteristics of building materials.2005.
64. Steiner AJ · 1943 · 69
65. 10.4224/2032995110.4224/20329951 ↗
66. 10.1007/978‐1‐4939‐2565‐0_2310.1007/978‐1‐4939‐2565‐0_23 ↗
67. 10.6028/NBS.TN.94510.6028/NBS.TN.945 ↗
68. 10.1002/fam.270710.1002/fam.2707 ↗
69. 10.1520/JTE10391110.1520/JTE103911 ↗
70. 10.1002/(SICI)1099-1018(199711/12)21:6<271::AID-FAM621>3.0.CO;2-110.1002/(SICI)1099-1018(199711/12)21:6<271::AID-FAM621>3.0.CO;2-1 ↗
71. ISO 9239‐1:2010.Reaction to fire tests for floorings — Part 1: Determination of the burning behaviour using a radiant heat source.2010.
72. Quintier JG · 1974 · 59
73. 10.1007/BF0258862610.1007/BF02588626 ↗
74. 10.1002/(SICI)1099-1018(199905/06)23:3<139::AID-FAM681>3.0.CO;2-010.1002/(SICI)1099-1018(199905/06)23:3<139::AID-FAM681>3.0.CO;2-0 ↗
75. Mehaffey J · 2014
76. Statistics Canada.Table 35‐10‐0192–01 Incident‐based fire statistics by type of fire incident and type of structure.2023. doi:10.25318/3510019201‐ENG
77. Statistics Canada.Table 35‐10‐0194‐01 Fire‐related deaths and persons injured by cause of death or injury and reason for non‐evacuation.2023. doi:10.25318/3510019401‐ENG
78. 10.1007/s10694‐022‐01223‐410.1007/s10694‐022‐01223‐4 ↗