Some properties of hardened cement paste and reinforcing bars upon cooling from elevated temperatures
Source abstract
Abstract
Abstract The post‐cooling properties of reinforced concrete constituents are of great relevance in the assessment of a structure for re‐use after fire. The expansive rehydration of dissociated calcium hydroxide on post‐cooling exposure to air can cause a total loss in strength if cement paste specimens are heated to and maintained at 400°C or above. The use of cement replacement agents can mitigate this effect. The strength and ductility of hot‐rolled mild steel and cold twisted steel on gradual cooling or quenching from various temperatures can be correlated with microstructural phenomena. There is a significant increase in strength and loss of ductility when both types of steel are quenched from temperatures above 723°C. Some practical implications of these properties are described, using examples of fire‐damaged structures.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Fire effects on concrete materials · Structural Response to Dynamic Loads · Engineering and Material Science Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (18)
Show source-provided references
1. 1975
2. 1978
3. Malhotra H. L. · 1982
4. BS8110:1985.Structural use of concrete.British Standards Institution London.
5. Assessment of fire‐damaged concrete structures and repair by gunite Concrete Society Technical Report No. 15 Concrete Society London (1978).
6. Mechanical properties of hardened cement paste exposed to temperatures up to 700°C (1292°F)
7. 10.1680/macr.1987.39.139.9310.1680/macr.1987.39.139.93 ↗
8. Petzold A. · 1970
9. Glasser F. P. · 1964 · 335
10. Resistance to fire of concrete and reinforced concrete
11. Resistance to fire of concrete and reinforced concrete
12. Harada T. · 1972 · 377
13. Honeycombe R. W. K. · 1981
14. Rollason E. C. · 1973
15. The effect of elevated temperatures on the strength properties of reinforcing and prestressing steels
16. BS4449:1978.Specification for hot rolled steel bars for the reinforcement of concrete.British Standards Institution London.
17. BS4461:1978.Specification for cold worked steel bars for the reinforcement of concrete.British Standards Institution London.
18. Structural damage and remedial measures for the fire affected library block in Chandigarh