Reduction of fire spalling of concrete with small doses of polypropylene fibres
Source abstract
Abstract
Summary The addition of polypropylene (PP) fibres has been shown to reduce the fire spalling propensity of concrete. When including this type of fibres in the concrete, the concrete mix becomes less robust, and small deviations in the constitutes change the workability and properties of the concrete. So, from a manufacturing perspective as small dosages as possible of PP fibres are desirable. Very few large‐scale fire resistance tests of concrete loaded in compression exist showing the function of PP fibres at low dosages on concrete mixes sensitive to spalling if no fibres are added. In this paper, results from 26 fire tests are presented and analysed. The test results are from four different experimental campaigns, but all the mixes have in common that the water‐to‐cement ratio is 0.40. The results show that an amount of only 0.6 kg/m3 PP fibres has a significant effect on the spalling propensity and that even lower amounts reduce the spalling although they do not eliminate it entirely. During one of the fire tests on large slabs loaded in compression, unloaded small cubes of the same mixes were also included in the furnace. None of the small specimens spalled, whereas some of the corresponding large slabs spalled beyond the layer of reinforcement. This illustrates that tests on small, unloaded specimens are not relevant when assessing fire spalling of larger cross‐sections loaded in compression.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Fire effects on concrete materials · Fire dynamics and safety research · Engineering and Material Science Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Fire Technology RISE, Research Institutes of Sweden Borås Sweden
References (33)
Show source-provided references
1. MalhotraHL.Spalling of Concrete in Fires. Construction Industry Research and Information Association Technical Report No. 118 London.1984.
2. Meyer‐OttensC.Zur Frage der Abplatzungen an Betonbauteilen aus Normalbeton bei Brandbeanspruchung PhD‐thesis (in German) Braunshweig Germany.1972.
3. JanssonR BoströmL.Fire tests of loaded beams. Paper presented at: Proceedings from the 2nd International RILEM Workshop on Concrete Spalling due to Fire Exposure Delft The Netherlands October 5‐7 2011.
4. GaryM.Brandproben an Eisenbetonbauten. Deutscher Ausschuss für Eisenbeton Heft 33(in German) Berlin Germany.1916.
5. JanssonR.Fire spalling of concrete ‐ A historical overview. Key note at the 3rd International RILEM Workshop on Concrete Spalling due to Fire Exposure Paris France September 2013.10.1051/matecconf/20130601001 ↗
6. HertzK.Explosion og reststyrke af vermepåvirket silikabeton (in Danish) Report 162 Institutet for Husbygning Danmarks Tekniska Högskole Ljungby.1982.
7. Spalling of high‐strength silica fume concrete in fire
8. DiederichsU JumppanenU‐M SchneiderU.High Temperature Properties and Spalling Behaviour of High Strength Concrete. Paper presented at: Proceedings of the Fourth Weimar Workshop on High‐Strength Concrete: Material Properties and Design Held at Hochschule fur Architcktur und Bauwesen (HAB) Weimar Germany Oct. 1995. pp.219–236.
9. BoströmL.The Performance of Some Self Compacting Concretes When Exposed to Fire. SP Report 2002:23 Borås Sweden.2003.
10. CopierWJ.Spalling of normalweight and lightweight concrete on exposure to fire. Report 24(2) Heron The Netherlands.1979.
11. JanssonR.Fire spalling of concrete‐ Theoretical and Experimental studies. PhD Thesis KTH Stockholm Sweden 2013.
12. ENV 1992‐1‐2 Design of concrete structures – Part 1–2: General rules – Structural fire design Brussels Belgium.1995.
13. Eurocode 2 1992‐1‐2: Design of concrete structures – Part 1–2: General rules – Structural fire design Brussels Belgium.2004.
14. Swedish Concrete Association.Preliminary Recommendations to Prevent Explosive Spalling in Concrete Structures Subjected to Fire (in Swedish) Betong No. 2 May 2004. pp.21–24.
15. Swedish Concrete Association.Concrete and Fire – Recommendations to Prevent Spalling in Civil Engineering Structures Concrete report No. 16 2011 Interimistic Edition (in Swedish) Stockholm Sweden.
16. PistolK WeiseF MengB SchneiderU.The mode of action of polypropylene Fibres in high performance concrete at high temperature. Paper presented at: Proceedings from the 2nd International RILEM Workshop on Concrete Spalling Due to Fire Exposure Delft the Netherlands October May 7 2011.
17. BoströmL.JanssonR.Self‐compacting concrete exposed to fire. SP Report 2008:53. Borås. Sweden.2008.
18. JanssonR BoströmL.Spalling of Concrete Exposed to Fire. SP Report 2008:52 Borås Sweden.2008
19. Shotcrete in fires: effects of fibers on explosive spalling
20. SilfwerbrandJ.Swedish recommendations for preventing fire spalling in concrete structures for civil engineering purposes. Paper presented at: Proceedings from the 2nd International Workshop on Concrete Due to Fire Exposure October 5‐7 2011 Delft The Netherlands.
21. Arup Group Ltd Fire resistance of concrete enclosures Work Package 2: Spalling categories report for the Nuclear Safety Directorate of the Health and Safety Executive London Great Britain.2005.
22. 10.1002/pse.5110.1002/pse.51 ↗
23. JohanssonT.Development of fire safe concrete‐ practical advice concerning testing. Report 12022 from SBUF the Development Fund of the Swedish Construction Industry (in Swedish) Stockholm Sweden.
24. EN 12390‐3. Testing hardened concrete – Part 3: Compressive strength of test specimen. December 2001 Brussles.
25. SalehI NilssonH.Manufacturing of self compacting concrete with a polypropylene addition. Report 11522 from SBUF the Development Fund of the Swedish Construction Industry (in Swedish) Stockholm Sweden.
26. EN 1363‐1:1999 Fire resistance tests – Part 1: General requirements Brussles 1999.
27. EN 1363‐2:1999 Fire resistance tests – Part 2: Alternative and additional procedures Brussles 1999.
28. BoströmL.Innovative Self‐Compacting Concrete ‐ Development of Test Methodology for Determination of Fire Spalling. SP Report 2004:06 Borås Sweden.2004. 224 pp.
29. 10.1617/s11527-012-0007-z10.1617/s11527-012-0007-z ↗
30. JumppanenU‐M.Effect of strength on fire behaviour of concrete Nordic Concrete Research Publication No. 8.1989.
31. ConnollyRJ.The spalling of concrete in Fires. PhD thesis Aston University Birmingham 1995. pp.294.
32. BoströmL JanssonR.Effect of Fire Exposure on Spalling of Concrete. Paper presented at: Proceedings from the 1st International Workshop on Concrete Spalling Due to Fire Exposure ‐ from Real Life Experiences and Practical Applications to Lab‐Scale Investigations and Numerical Modelling MFPA Institute Leipzig Germany. September 3–5 2009.
33. MoritaT NishidaA YamazakiN SchneiderU DiederichsU.An Experimental Study on Spalling of High Strength Concrete Elements under Fire Attack. Fire Safety Sience‐ Proceedings of the Sixth International Symposium Poitiers France.2000 pp.855–866.10.3801/IAFSS.FSS.6-855 ↗