journal article·2020-04Open access

Best practices for modeling structural boundary conditions due to a localized fire

Alyssa DeSimone, Ann E. Jeffers

Fire and Materials· Volume 44· Issue 3

Abstract

Summary Recent studies suggest the assumption of uniform heating that is used in current structural fire design cannot be assumed conservative, especially if the fire is expected to burn locally. Aside from design equations, which have limited applicability, a common approach to simulating structural members subjected to a localized fire is modeling the fire‐structure interaction using a coupled computational fluid dynamics (CFD)‐finite element (FE) model. In the existing literature, a wide range of methods and parameters are used when determining the boundary conditions at the fire‐structure interface, specifically regarding the representation of net heat flux, heat transfer coefficient, and surface emissivity of steel. The purpose of this study is to investigate various methods for representing the boundary conditions in terms of accuracy and computational efficiency and then identify best practices. In conclusion, our study found that net heat flux predicted by adiabatic surface temperature, a nonconstant heat transfer coefficient, and a surface emissivity of 0.9 for steel was the most reliable thermal boundary condition in a coupled CFD‐FE model of a localized fire. These recommendations are based on the two cases studied here, and caution should be used when applying these results to future studies.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Fire dynamics and safety research · Fire effects on concrete materials · Fire effects on ecosystems

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Civil and Environmental Engineering University of Michigan Ann Arbor Michigan

References (17)

Show source-provided references
1. 10.1016/j.jcsr.2013.02.00110.1016/j.jcsr.2013.02.001 ↗
2. 10.1016/j.jcsr.2010.07.00710.1016/j.jcsr.2010.07.007 ↗
3. 10.1016/j.jcsr.2014.11.01210.1016/j.jcsr.2014.11.012 ↗
4. 10.1007/978-3-319-30172-310.1007/978-3-319-30172-3 ↗
5. EN 1991‐1‐2.Eurocode 1: Actions on structures—part 1‐5: general actions—actions on structures exposed to fire.Eurocode 1.2002;2(2002):61
6. 10.1108/JSFE-09-2016-01510.1108/JSFE-09-2016-015 ↗
7. 10.1007/s13296-013-3013-210.1007/s13296-013-3013-2 ↗
8. 10.1016/j.firesaf.2016.04.00710.1016/j.firesaf.2016.04.007 ↗
9. 10.1007/s10694-015-0495-910.1007/s10694-015-0495-9 ↗
10. LaMalva KJ · 2018
11. KamikawaD HasemiY YamadaK NakamuraM.Mechanical responses of a steel column exposed to a localized fire.In the proceedings of the fourth international workshop on structures in fire.2006:225‐234.
12. HigginsonS MorrisG.Modelling heat transfer to a steel‐beam.Master's in engineering Thesis University of Edinburgh;2012.
13. 10.1016/j.firesaf.2015.05.00810.1016/j.firesaf.2015.05.008 ↗
14. 10.1016/j.firesaf.2013.03.01110.1016/j.firesaf.2013.03.011 ↗
15. McgrattanK McdermottR.Sixth Edition Fire Dynamics Simulator User's Guide;2016.https://doi.org/10.6028/NIST.SP.1019.10.6028/NIST.SP.1019 ↗
16. 10.1002/fam.266010.1002/fam.2660 ↗
17. Incropera F · 2011