journal article·2024-04Open access

Residual mechanical resistance of concrete blocks and laying mortars after high temperatures

Rafaela de Oliveira Amaral, Armando Lopes Moreno, Wallison Angelim Medeiros, Guilherme Aris Parsekian

Fire and Materials· Volume 48· Issue 3

Abstract

Abstract This paper reports an experimental campaign to evaluate the residual mechanical resistance after high temperatures of two structural masonry components: block and mortar. Residual compressive strength and deformation modulus of four different hollow concrete blocks and two different mortar mixes after heating at high temperatures are investigated. The test method used was the one recommended by RILEM TC 200 for mortars and an adaptation of the same method proposed by Medeiros et al. suitable for the geometry of hollow blocks. Despite the sharp drop in the deformation modulus after heating blocks and mortar, no different behaviours are observed in the deformability of the materials caused by the variables studied. The same cannot be said in relation to the variation of the residual compressive strength of the blocks, which is affected by the variables: initial nominal compressive strength and width of the concrete block. Regarding laying mortars, the results confirmed the small influence of compressive strength on the evolution of residual mechanical strength. The data and analyses reported here on the residual mechanical properties of hollow concrete blocks produced from a concrete mixture of very dry consistency, vibro‐pressed and with normal weight aggregates are relevant, since the data found in the literature generally refer to the wet cast concrete material and in cylindrical bodies.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Fire effects on concrete materials · Structural Response to Dynamic Loads · Rock Mechanics and Modeling

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Civil Engineering University of Campinas Campinas Brazil

Department of Civil Engineering Federal University of São Carlos Sao Carlos Brazil

Funding

Fundação de Amparo à Pesquisa do Estado de São Paulo

References (22)

Show source-provided references
1. 10.1016/j.conbuildmat.2023.13108510.1016/j.conbuildmat.2023.131085 ↗
2. 10.1617/s11527‐022‐01892‐110.1617/s11527‐022‐01892‐1 ↗
3. Mechanical properties and structural behaviour of masonry at elevated temperatures
4. 10.1201/9781003098508‐7810.1201/9781003098508‐78 ↗
5. 10.1617/s11527‐007‐9286‐110.1617/s11527‐007‐9286‐1 ↗
6. 10.1590/s1983‐4195202100040000810.1590/s1983‐41952021000400008 ↗
7. Internacional Organization for Standardization.ISO 834‐1: Fire Resistance Tests—Elements of Building Construction—Part 1: General Requirements.1999.
8. 10.1002/fam.308510.1002/fam.3085 ↗
9. 10.1016/S0008-8846(02)00709-310.1016/S0008-8846(02)00709-3 ↗
10. 10.1016/j.cemconres.2004.01.01510.1016/j.cemconres.2004.01.015 ↗
11. 10.5433/1679‐0375.2011v32n1p4710.5433/1679‐0375.2011v32n1p47 ↗
12. 10.1002/fam.107410.1002/fam.1074 ↗
13. 10.1016/j.firesaf.2008.02.00110.1016/j.firesaf.2008.02.001 ↗
14. 10.1016/j.conbuildmat.2018.09.02710.1016/j.conbuildmat.2018.09.027 ↗
15. 10.1016/j.conbuildmat.2019.05.19310.1016/j.conbuildmat.2019.05.193 ↗
16. 10.1016/j.conbuildmat.2022.12661310.1016/j.conbuildmat.2022.126613 ↗
17. 10.1520/C0595_C0595M‐2110.1520/C0595_C0595M‐21 ↗
18. American Concrete Institute The Masonry Society.ACI/TMS 216.1: Code Requirements for Determining Fire Resistance of Concrete and Masonry Construction Assemblies 28.2014.
19. European Committee for Standardization.EN 1992‐1‐2: Design of Concrete Structures—Part 1–2: General Rules—Structural Fire Design 1 97.2004.
20. American Concrete Institute.ACI 216R‐89: Guide for Determining the Fire Endurance of Concrete Elements.1996.
21. 10.1590/s1983‐4195201000040000510.1590/s1983‐41952010000400005 ↗
22. 10.1016/j.cemconres.2007.09.02010.1016/j.cemconres.2007.09.020 ↗