A probabilistic thermal radiation analysis of cooking hob separation distance in open plan kitchens
Source abstract
Abstract
Abstract Cooking oil fires present a hazard to the occupants of residential flats with open plan kitchens where the means of escape passes fixed cooking appliances. Recent guidance has proposed a separation distance of 1.8 m from a hob/stovetop, but the basis of this advice is unclear. This paper carries out a probabilistic thermal radiation analysis using the thermal fractional effective dose (FED) methodology to assess the likelihood that the specified separation distance will be exceeded. Statistical data collected from a previous survey of cooking oil usage is used to determine reasonable worst‐case maximum heat release rate values as input to the point source model to calculate thermal radiation exposure. Occupant exposure times are assessed using walking speeds based on occupant demographics. The analysis suggests that the 1.8 m criterion equates to approximately a 99th percentile where there is no cap on the heat flux that an occupant can tolerate. This falls to the 88th percentile when the maximum tolerable heat flux is capped at 2.5 kW/m2to account for vulnerable occupants.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Fire dynamics and safety research · Wind and Air Flow Studies · Evacuation and Crowd Dynamics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
OFR Consultants Manchester UK
Ashton Fire Manchester UK
References (38)
Show source-provided references
1. BSI · 2011
2. Fire safety design of open plan apartments in England
3. Fraser‐Mitchell J · 2009
4. Open plan apartments ‐ revisiting risks in light of contemporary demands
5. BSI · 2015
6. ABCB National Construction Code Volume one ‐ building code of Australia 2019 amendment 1 Australian Building Codes Board 2019.
7. Ministry of Business Innovation & EmploymentC/AS2 acceptable solution for buildings with sleeping (non institutional) for New Zealand building code clauses C1‐C6 protection from fire. New Zealand Government 2016.
8. NRCC · 2015
9. ICC · 2015
10. NFPA · 2017
11. Government of Ireland · 2020
12. BSI Draft British Standard BS 9991 Fire safety in the design management and use of residential buildings.2021.
13. 10.1177/073490412092356610.1177/0734904120923566 ↗
14. WadeC BakerG FrankK HarrisonR SpearpointM.B‐RISK 2016 user guide and technical manual’ Building Research Association of New Zealand SR364 2016.
15. McGrattanK HostikkaS McDermottR FloydJ VanellaM.Fire dynamics simulator user's guide. National Institute of Standards and Technology Gaithersburg MD NIST SP 1019 2019.10.6028/NIST.SP.1019
16. McGrattanK HostikkaS McDermottR FloydJ VanellaM.Fire dynamics simulator technical reference guide volume 1: mathematical model. National Institute of Standards and Technology Gaithersburg MD NIST SP 1018‐1 2019.10.6028/NIST.SP.1018
17. 10.1007/978-1-4939-2565-0_6610.1007/978-1-4939-2565-0_66 ↗
18. 10.1177/0734904121101299410.1177/07349041211012994 ↗
19. 10.1106/F9XE-5J38-T4F0-JTEB10.1106/F9XE-5J38-T4F0-JTEB ↗
20. 10.1016/j.firesaf.2020.10307010.1016/j.firesaf.2020.103070 ↗
21. 10.1007/978-1-4939-2565-0_6310.1007/978-1-4939-2565-0_63 ↗
22. BSI PD 7974‐6:2019 Application of Fire Safety Engineering Principles to the Design of Buildings. Human Factors. Life Safety Strategies. Occupant Evacuation Behaviour and Condition (Sub‐System 6). BSI London 2019.
23. HaminsAP MadrzykowskiD KimSC KentJ.Investigation of residential cooking fire suppression technologies. National Institute of Standards and Technology Gaithersburg MD NIST TN 1969 2018.10.6028/NIST.TN.1969 ↗
24. 10.1177/073490411876188410.1177/0734904118761884 ↗
25. 10.1152/jappl.1959.14.3.37310.1152/jappl.1959.14.3.373 ↗
26. 10.1002/978111997546510.1002/9781119975465 ↗
27. UL Outline of investigation for extinguishing system units for residential range top cooking surfaces. Underwriters Laboratories Inc. UL 300A (Issue 3) 2006.
28. 10.1177/073490412199039210.1177/0734904121990392 ↗
29. Karlsson B · 2000
30. LordJ MeachamB MooreA FahyR ProulxG.Guide for evaluating the predictive capabilities of computer egress models. National Institute of Standards and Technology Gaithersburg MD USA NIST GCR 06‐886 2005.
31. Office for National Statistics Population by ethnicity ‐ Age groups.2018.https://www.ethnicity-facts-figures.service.gov.uk/uk-population-by-ethnicity/demographics/age-groups/latest
32. BSI BS EN 81‐76. Safety rules for the construction and installation of lifts. Particular applications for passengers and goods passenger lifts. Part 76. Evacuation of persons with disabilities using lifts. BSI London 2019.
33. Greater London Authority The London Plan: The spatial development strategy for greater London. Greater London Authority 2021.https://www.london.gov.uk/sites/default/files/the_london_plan_2021.pdf
34. BSI PD 7974‐7:2019+A1:2021 Application of fire safety engineering principles to the design of buildings. Probabilistic risk assessment. BSI London 2021.
35. 10.1007/s10694-019-00925-610.1007/s10694-019-00925-6 ↗
36. BSI PD 7974–1:2019 Application of fire safety engineering principles to the design of buildings. Initiation and development of fire within the enclosure of origin (Sub‐system 1). BSI London 2019.
37. Estimating door open time distributions for occupants escaping from apartments
38. 10.3390/su1220845310.3390/su12208453 ↗