journal article·2018-11

Flexural behavior of hybrid PVA fibers reinforced ferrocement panels at elevated temperatures

N.F. Abushawashi, V. Vimonsatit, F.U.A. Shaikh

Fire and Materials· Volume 42· Issue 7
Publisher page

Abstract

Summary Fire safety should consider not only the performance of the structure after the fire but also the behavior during the fire. The structural fire reliability performance of hybrid PVA fiber reinforced ferrocement (HFF) panels is experimentally determined based on its flexural characteristics and damage during the exposure to elevated temperatures. The residual compressive strength of 60 cubs was also tested after exposed to temperatures. In addition, 30 HFF panels were tested to evaluate their structural capacity by conducting an in‐situ binding test during the heating of up to 200°C, 400°C, 600°C, and 800°C, and compared with control samples tested at ambient (24°C) temperature condition. The main parameters investigated were the specimen thickness and the effect of using mineral admixtures (fly ash and silica fume) in the mortar mixtures. The results show a strength decline of both flexural and compressive strengths as temperature increases. The bending capacity at 800°C is reduced to about 90% of the ambient capacity only. In between the 2 temperatures, the reduction rate is found to be almost linear. A theoretical prediction of the moment capacity reduction shows a good agreement with the test results.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Fire effects on concrete materials · Structural Behavior of Reinforced Concrete · Innovative concrete reinforcement materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Civil Engineering Curtin University Perth Australia

References (40)

Show source-provided references
1. ACI committee 549R‐97 State of the art report on ferrocement. in ACI 549R‐97.1997.
2. P, P · 2001 · 99
3. Prefabricated ferrocement water tank
4. Innovation, A.H.P.o.t.A.C.o.T · 1973
5. Effects of arrangements of reinforcements on mechanical properties of ferrocement
6. Naaman AE · 2000
7. 10.1201/b1284510.1201/b12845 ↗
8. Allen C · 2006
9. Thermal expansion of Portland cement paste, mortar and concrete at high temperatures
10. Kodur V.K.R.andP.R.N.W.P. 002. Fire resistance evaluation of large scale structural system in fire resistance determination and performance.2002.
11. 10.1016/j.cemconres.2009.10.01710.1016/j.cemconres.2009.10.017 ↗
12. Variation of mortar and concrete properties and temperature
13. 10.1016/0379-7112(88)90033-110.1016/0379-7112(88)90033-1 ↗
14. 10.1061/(ASCE)MT.1943-5533.000033510.1061/(ASCE)MT.1943-5533.0000335 ↗
15. Reinforced concrete structures in and after fire
16. Nishida A. et al. Study on the properties of high strength concrete with short polypropylene fibres for spalling resistance. in Concrete Under Severe Environment. 1995.
17. 10.1002/fam.81018010610.1002/fam.810180106 ↗
18. Greepala V. R.Parichatprecha andT.Tanchaisawat Specific heat capacity of ferrocement using inverse thermal analysis. RSID6‐ STR‐10 http://fscieng. csc. ku. ac. th/~ce/images/stories/paper/vatwong_rsid_str100.pdf (Accessed at8‐2011).
19. 10.1016/j.cemconcomp.2007.08.00710.1016/j.cemconcomp.2007.08.007 ↗
20. 10.1016/0958-9465(95)00031-710.1016/0958-9465(95)00031-7 ↗
21. Bending response of hybrid ferrocement plates with meshes and fibre
22. 10.1016/j.conbuildmat.2006.06.02110.1016/j.conbuildmat.2006.06.021 ↗
23. 10.3844/ajassp.2009.219.22310.3844/ajassp.2009.219.223 ↗
24. Strain‐hardening behaviour of hybrid fibre reinforced cement composites
25. 10.1016/j.conbuildmat.2006.01.00210.1016/j.conbuildmat.2006.01.002 ↗
26. 10.1617/s11527-010-9691-810.1617/s11527-010-9691-8 ↗
27. Australian Standard General purpose and blended cements in AS 3972.2010 Standard Australia
28. 10.1016/j.cemconcomp.2011.11.01910.1016/j.cemconcomp.2011.11.019 ↗
29. AS 1012.9 Methods of testing concrete‐compressive strength tests Concrete Mortar and Grout Specimens Standards Australia 2014
30. Effect of nano silica and fine sand on the compressive strength of sodium and potassium synthetized fly ash geopolymers at elevated temperatures
31. 10.1016/j.jobe.2016.10.00510.1016/j.jobe.2016.10.005 ↗
32. 10.1007/BF0247307710.1007/BF02473077 ↗
33. Compressive strength of fly‐ash‐based geopolymer concrete at elevated temperatures
34. 10.1016/0958-9465(91)90045-J10.1016/0958-9465(91)90045-J ↗
35. 10.1016/j.cemconcomp.2012.08.00410.1016/j.cemconcomp.2012.08.004 ↗
36. Mehta PK · 2006 · 644
37. 10.1016/j.conbuildmat.2007.07.03310.1016/j.conbuildmat.2007.07.033 ↗
38. 10.1533/9780857093080.26310.1533/9780857093080.263 ↗
39. 1994–1‐2 E. Eurocode 4: design of composite steel and concrete structures—part 1–2.2005.
40. 10.1061/(ASCE)0899-1561(1994)6:4(513)10.1061/(ASCE)0899-1561(1994)6:4(513) ↗