journal article·2014-01

Experimental study of the fire resistance of walls and floors constructed with steel studs and steel joists

In‐Kyu Kwon, NamYong Jee

Fire and Materials· Volume 38· Issue 1
Publisher page

Abstract

ABSTRACT Steel‐framed houses using light‐gauge steel as a structural member have been developed and constructed since the early 2000s as a new construction pattern in the low‐rise construction market in Korea. Generally, the steel frames consist of two major load‐carrying elements such as load‐bearing wall and floor construction made up of approximately 1.0‐mm cold‐formed light‐gauge steel and light‐weight boards. Therefore, the steel frames are very simple to construct and make the construction period shorter than the ordinary construction type or concrete‐based construction. In Korea, regardless of the construction material types, the building regulation requires 1‐h fire rating for apartment buildings of four stories or under. To meet the fire resistance, new models of load‐bearing wall and floor should be developed. From the fire test results, two layer gypsum boards of 12.5 mm in thickness reinforced with glass fiber were proven satisfactory to provide 1‐h fire resistance with load‐bearing wall and floor. Copyright © 2012 John Wiley & Sons, Ltd.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Fire effects on concrete materials · Structural Behavior of Reinforced Concrete · Structural Load-Bearing Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Kangwon National University 245‐711, Joongangro 1 Samcheok Gangwon‐do Korea

Hanyang University 133‐791, Hangdang‐dong 17 Sungdong‐Ku Seoul Korea

References (25)

Show source-provided references
1. Pohang Steel & Iron Company.Design and Construction Report on Model Steel House 1997.
2. National Association Home Builders.Fire and Acoustic Performance of Light Gauge Steel Framing 2001.
3. Institute for Research in Construction National Research Council Canada.Building Science Insight. Seminar Series2002 Sound Isolation and Fire Containment—Details That Work.
4. Steel Construction Institute.Acoustic and fire performance of light‐steel frame housing. Interim Report to NAHBRC 2001.
5. 10.1016/S0379-7112(02)00090-510.1016/S0379-7112(02)00090-5 ↗
6. 10.1016/S0379-7112(03)00070-510.1016/S0379-7112(03)00070-5 ↗
7. 10.1016/S0263-8231(03)00002-810.1016/S0263-8231(03)00002-8 ↗
8. 10.1016/j.firesaf.2004.08.00210.1016/j.firesaf.2004.08.002 ↗
9. 10.1007/s10694-005-3730-y10.1007/s10694-005-3730-y ↗
10. 10.1002/(SICI)1099-1018(199603)20:2<79::AID-FAM566>3.0.CO;2-N10.1002/(SICI)1099-1018(199603)20:2<79::AID-FAM566>3.0.CO;2-N ↗
11. 10.1002/fam.88010.1002/fam.880 ↗
12. The Ministry of Construction and Transportation.Building regulation 2005.
13. UL.UL Directory 2003.
14. Korean Standard Association. KSF3504.Gypsum boards 2009.
15. American Standard for Testing and Methods · 2001
16. Society of Fire Protection Engineers · 1995
17. Holman JP · 1992
18. SP · 2003
19. Petterson O · 1976
20. Sterner E · 1990
21. Korean Standard Association. KSF2257‐1.Methods of fire resistance test for elements of building construction—general requirements 2005.
22. Derivation of the mechanical properties of structural steels at high temperature
23. Korean Standard Association. KSF2257‐4.Methods of fire resistance test for elements of building construction‐specific requirements for loadbearing vertical separating elements 2009.
24. Korean Standard Association. KSF2257‐5.Methods of fire resistance test for elements of building construction‐specific requirements for loadbearing horizontal separating elements 2005.
25. Research Institute of Science & Technology · 2001