Comparing simple and advanced tools for structural fire safety engineering
Source abstract
Abstract
Summary The present paper gives an overview of the actual tools available for the estimation of the fire development and of the resulting thermal actions on structural members. A case study is developed on the basis of the Fire Safety Engineering methodology, respectively with two different approaches, one based on ‘advanced’ tools and another one based on ‘simplified’ tools. Indeed, three categories of fire models are used in this study, each of which corresponding to a different level of precision and complexity: hand calculations, zone models, and computational fluid dynamics (CFD) models. The case study is relative to the calculation of the heating of a portal frame in a gymnasium, under localised real fire conditions. It is shown through comparisons that, in this case, predictions of analytical methods are, to certain extent, in good agreement with predictions of the CFD model. In particular, it is demonstrated the relevance of using a simplified method of EN 1991‐1‐2 to predict thermal actions to vertical members. The obtained results also highlight the need to develop more relevant analytical methods in order to predict the temperature field during a fire in a large volume. Copyright © 2014 John Wiley & Sons, Ltd.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Fire dynamics and safety research · Fire effects on concrete materials · Wind and Air Flow Studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
CTICM (Centre Technique Industriel de la Construction Métallique) Saint‐Aubin France
References (21)
Show source-provided references
1. EN 1991‐1‐2.Eurocode 1: Actions on structures ‐ Part 1‐2: General actions ‐ Actions on structures exposed to fire. European Committee for Standardisation (CEN) Brussels Belgium 2002.
2. The Right Tool for the Job
3. 10.1177/104239150605692610.1177/1042391506056926 ↗
4. 10.1016/j.proci.2012.09.00710.1016/j.proci.2012.09.007 ↗
5. 10.1016/0379-7112(86)90052-410.1016/0379-7112(86)90052-4 ↗
6. 10.1177/104239150301300200110.1177/1042391503013002001 ↗
7. ProfilARBED Université de Liège CTICM TNO Labein.Development of design rules for steel structures subjected to natural fires in Large Compartments. ECSC Agreement No 7210‐SA/210/317/517/619/932. Final Report EUR 18868 EN 1999.
8. ISO/TS 24679:2011.Fire safety engineering ‐ Performance of structures in fire. ISO Geneva Switzerland 2011.
9. ISO/TS 13447:2013.Fire safety engineering ‐ Guidance for use of fire zone models. ISO Geneva Switzerland 2013.
10. ISO/TS 16733:2006.Fire safety engineering ‐ Selection of design fire scenarios and design fires. ISO Geneva Switzerland 2006.
11. 10.1016/j.firesaf.2012.06.00310.1016/j.firesaf.2012.06.003 ↗
12. HopkinDJ.Testing the single zone structural fire design hypothesis.Interflam 2013 Proceedings of the 13thInternational Conference University of London UK 2013;139–150.
13. McGrattanK McDermottK HostikkaS FloydJ.Fire Dynamics Simulator (Version 5) ‐ User's Guide. NIST Special Publication 1019‐5 SVN Repository Revision: 6701 September 3 2010.
14. ANSYS.ANSYS User's Manual for Revision 14.0 ‐ Volume IV – Theory. Swanson Analysis SYSTEM INC. Houston USA 1992.
15. ZhaoB DesanghereS DarcheJ.CFD and FEM Coupling With Computer Codes FDS and ANSYS For Fire Resistance Interflam 2007 Proceedings of the 11thInternational Conference University of London UK 2007;1461–1466.
16. BRE Arcelor Profil Luxembourg CTICM TNO Efectis Université de Liège.FIRESTRUC ‐ Integrating advanced three‐dimensional modelling methodologies for predicting thermo‐mechanical behaviour of steel and composite structures subjected to natural fires. Final Report of RFCS Project Contract No RFS‐CR‐030300 2007.
17. ThauvoyeC VassartO ZhaoB.Analytical method for the calculation of heat fluxes received by a vertical member subjected to a localized fire in an open car park.Interflam 2013 Proceedings of the 13thInternational Conference University of London UK 2013;1083–1094.
18. JonesW PeacockR ForneyG RenekeP.CFAST ‐ Consolidated Model of Fire Growth and Smoke Transport (Version 6) ‐ Technical Reference Guide. NIST Special Publication 1026 2005.10.6028/NIST.SP.1041 ↗
19. NFPA 92B.Guide for Smoke Management Systems in Malls Atria and Large Areas 2000Edition. NFPA.
20. 10.1016/j.compositesa.2005.01.03010.1016/j.compositesa.2005.01.030 ↗
21. 10.1002/fam.81010030410.1002/fam.810100304 ↗