Abstract

Abstract The abuse of cigarette lighters, especially by juveniles, poses a serious fire safety challenge. Little information is available on the cigarette ignition performance of these devices or the ignition hazard these devices present to other objects. The current investigation focuses on characterizing the ignition propensity of cigarette lighters through carefully designed and controlled experiments. Cigarette lighters with port-type and Bunsen-type burner designs were adjusted to produce 75 W flames for all experiments. Temperature, heat flux, and ignition propensity measurements were performed in the flame and plume regions above these lighters. Even with the small source sizes used in this investigation, the temperature measurements from both burner types followed the turbulent plume scaling laws and compared favorably with large-scale fire measurements. However, significant differences were observed in the measured heat fluxes from port- and Bunsen-type flames having the same energy release rate of 75 W.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fire dynamics and safety research · Combustion and Detonation Processes · Wind and Air Flow Studies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (11)

Show source-provided references
1. Laitinen D. Candle fires on the rise. Nat Fire Protection Assoc J 2003.
2. Morton BR, Taylor G, Turner JS, Turbulent gravitational convection from maintained and instantaneous sources. Proceedings of the royal society of London, series A, vol. 234, 1956. 1–23.10.1098/rspa.1956.0011 ↗
3. McCaffrey BJ, Purely buoyant diffusion flames: some experimental results. National Engineering Laboratory, Center for Fire Research, National Bureau of Standards, No. NBSIR 79-1910, 1979.10.6028/NBS.IR.79-1910 ↗
4. Theory of steady laminar natural convection above a horizontal line heat source and a point heat source10.1016/0017-9310(63)90015-2 ↗
5. Alpert RL, Fire induced turbulent ceiling jet. Factory Mutual Research Corporation, FMC 19722-2, 1971.
6. Veldman CC, Kubota T, Zukoski EE. An experimental investigation of the heat transfer from a buoyant gas plume to a horizontal ceiling—part 1. Unobstructed ceiling. National Engineering Laboratory, Center for Fire Research, National Bureau of Standards, No. NBS-GCR-77-97, 1975.
7. Faeth GM, You HZ. An investigation of fire impingement on a horizontal ceiling. National Engineering Laboratory, Center for Fire Research, National Bureau of Standards, No. NBS-GCR-81-304 (1981).
8. Incropera · 2002
9. Williamson JW. Characterizing cigarette lighter flames to reduce unwanted ignition. MS thesis, University of Maryland, 2004.
10. Some source-dependent effects of unbounded fires10.1016/0010-2180(85)90027-6 ↗
11. Engineering relations for fire plumes10.1016/0379-7112(84)90005-5 ↗