journal article·2007-09

Finite element modelling of steel fin plate connections in fire

M. Sarraj, I.W. Burgess, J.B. Davison, R.J. Plank

Fire Safety Journal· Volume 42· Issue 6-7
Publisher page

Abstract

Abstract Recent structural collapses caused by fire have focused attention on research concerning fire safety in building design. Steel connections are an important component of any structural steel building, as they provide links between the principal structural members. The evaluation of the performance of steel connections at elevated temperatures has been a topic of several research programmes in the last few years. Determining the behaviour, available strength and stiffness of moment connections in fire conditions has been a dominant theme in these research works; however very little information on the behaviour of simple shear connections in fire conditions has been disseminated. Fin plate shear connections are easy to fabricate and install; as a result, they have gained popularity with fabricators because of their economy. In this research, the robustness of simple fin plate beam-to-column connections is being investigated under catenary tension from highly deflected beams in fire. A highly detailed three-dimensional (3-D) finite element (FE) model has been created using the ABAQUS software. This is a complex model accounting for material and geometric non-linearity, large deformation and contact behaviour. Contact is critical to model the shear behaviour of the joint, and contact elements have been used both at the bolt–hole interface and also at the surface between the web of the beam and the fin plate, taking into consideration friction between the surfaces. The connection model has been analysed through the elastic and plastic ranges up to failure. Bolt shear and bending, and plate and web bearing have been observed as failure modes. A comparison between available experimental data at ambient and elevated temperatures and other analytical results shows that the model has a high level of accuracy. When the connection model was extended to include an attached beam, it was found that it eventually experiences large tensile force when exposed to fire.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fire effects on concrete materials · Structural Load-Bearing Analysis · Fire dynamics and safety research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (28)

Show source-provided references
1. British Steel Corporation, Compendium of UK standard fire test data on unprotected structural steel, Contract report for Department of Environment. 1987.
2. Shepherd PG. The performance in fire of restrained columns in steel-framed construction. PhD thesis, University of Sheffield; 1999.
3. Kruppa J. Résistance en feu des assemblages par boulous. Centre Technique Industriel de la Construction Métallique, St. Remy les Chevreuse, France, CTTICM Report, document no. 1103-1, English translation available entitled “Fire Resistance of Joints with High Strength Bolts”, 1976.
4. British Steel, The performance of beam/column/beam connections in the BS5950: part 8 Fire Test. British Steel (Swinden labs), Report T/RS/1380/33/82D and T/RS/1380/34/82D, Rotherham; 1982.
5. Leston-Jones LC. The Influence of semi-rigid connections on the performance of steel framed structures in fire, PhD thesis, Department of Civil and Structural Engineering, University of Sheffield; 1997.
6. Elevated temperature moment-rotation tests on steelwork connections10.1680/istbu.1997.29830 ↗
7. Behaviour of steel and composite beam-column connections in fire10.1016/S0143-974X(98)00059-5 ↗
8. Al-Jabri KS. Behaviour of steel and composite beam-column connections in fire. PhD Thesis, Department of Civil and Structural Engineering, University of Sheffield; 1999.
9. Moment–rotation–temperature curves for semi-rigid joints10.1016/j.jcsr.2004.09.001 ↗
10. Spyrou S. Development of Components Based Model of Steel Beam-to-Column Joint at Elevated Temperatures. PhD Thesis, Department of Civil and Structural Engineering, University of Sheffield; 2002.
11. Finite element modelling of behaviours of steel beams and connections in fire10.1016/0143-974X(95)00016-O ↗
12. Three-dimensional modelling of steel/concrete composite connection behaviour in fire10.1016/S0143-974X(98)80038-2 ↗
13. Behaviour of extended end plate connections at high temperature10.1016/S0143-974X(98)00106-0 ↗
14. Al-Jabri KS, Seibi A, Karrech A. Modelling of unstiffened flush end-plate bolted connections in fire. J Const Steel Res 2005 [in press].10.1016/j.jcsr.2005.04.016 ↗
15. A component model for the behaviour of steel joints at elevated temperatures10.1016/S0143-974X(01)00039-6 ↗
16. Experimental and analytical investigation of the ‘tension zone’ components within a steel joint at elevated temperatures10.1016/j.jcsr.2003.10.006 ↗
17. Experimental and analytical investigation of the ‘compression zone’ components within a steel joint at elevated temperatures10.1016/j.jcsr.2003.10.005 ↗
18. Component-based model of the behaviour of flexible end-plate connections at elevated temperatures10.1016/j.compstruct.2004.04.040 ↗
19. Spring-stiffness model for flexible end-plate bare-steel joints in fire10.1016/j.jcsr.2005.05.003 ↗
20. Experimental investigation of behaviour of axially restrained steel beams in fire10.1016/S0143-974X(01)00062-1 ↗
21. Analyses of the effects of cooling and fire spread on steel-framed buildings10.1016/S0379-7112(96)00027-6 ↗
22. A numerical study of large deflection behaviour of restrained steel beams at elevated temperatures10.1016/j.jcsr.2003.09.005 ↗
23. ABAQUS/Standard, User's Manual I-III, version 6.3, Hibbit, Karlsson and Sorenson, Inc.; 2001.
24. ABAQUS, Theory Manual, version 6.3, Providence, RI: Hibbit, Karlsson and Sorenson, Inc.; 2001.
25. The analysis and design of single plate framing connections
26. Studies of the behaviour of steel beams in fire10.1016/0143-974X(91)90020-2 ↗
27. Wald F, Simoes da Silva L, Moore D, Santiago A. Experimental behaviour of steel joints under natural fire. ECCS—AISC Workshop, June 3–4, 2004.
28. European Committee for Standardization, EN 1993-1-2: Eurocode 3: Design of steel structures, Part 1.2: Structural fire design, 2005.