Temperatures during fire tests on structure and its prediction according to Eurocodes
Source abstract
Abstract
Abstract The paper reports on an experimental programme to investigate the global structural behaviour of a compartment in the three-storey steel frame building in a plant of the Mittal Steel Ostrava exposed to fire before demolition. The research project of the Czech Technical University in Prague was focussed on the examination of the temperature development within the various unprotected structural elements and its connections, the corresponding distribution of horizontal forces and the behaviour of the laterally unrestrained beams during the natural fire. The experiment also allowed studying of the heating of external elements, the influence of connection in a wall of sandwich panels, the temperature development in light timber-based panel and the degradation of the timber concrete composite element. Before the compartment fire, a local fire was prepared to verify the models of the temperature development in an unprotected column. The comparisons to the simplified calculations by European standards are included in the text to show their strong and weak points in prediction of temperatures of gas and structural elements during fire.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fire effects on concrete materials · Fire dynamics and safety research · Concrete Properties and Behavior
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (14)
Show source-provided references
1. Buchanan · 2000
2. D.B. Moore, Steel fire tests on a building frame, Building Research Establishment, Paper No. PD220/95, Watford, 1995, p. 13.
3. O. Pettersson, S.E. Magnusson, J. Thor, Fire engineering design of steel structures, Publication No. 50, Swedish Institute of Steel Construction, Stockholm, 1976.
4. The temperature attained by unprotected structural steelwork in experimental natural fires10.1016/0379-7112(87)90029-4 ↗
5. J. Witteveen, L. Twilt, F.S. Bijlaard, The stability of braced and unbraced frames at elevated temperatures, in: International Symposium of Stability of Steel Structures, Liège, 1977.
6. The inherent fire resistance of a loaded steel framework
7. Experimental behaviour of a steel structure under natural fire10.1016/j.firesaf.2006.05.006 ↗
8. The behaviour of full-scale steel-framed building subject to compartment fires
9. P. Kallerová, F. Wald, Ostrava fire test, CIDEAS Report No. 3-2-2-4/2, Czech Technical University, Prague, 2006, p. 18.
10. Eurocode 1, EN-1991-1-2: 2002, Part 1.2: General actions—actions on structures exposed to fire, European Committee for Standardization, Brussels, 2002.
11. Eurocode 3, EN-1993-1-2: 2005, Part 1.2: Design of steel structures—structural fire design, CEN, European Committee for Standardization, Brussels, 2005.
12. Eurocode 3, EN-1993-1-8: 2005, Part 1.8: Design of steel structures—design of joint, CEN, European Committee for Standardization, Brussels, 2005.
13. M. Law, T. O’Brien, Fire safety of bare external structural steel, SCI, No. 009, London, 1989, p. 88, ISBN 0-86200-026-2.
14. Temperature distribution in a full-scale steel framed building subject to a natural fire10.12989/scs.2006.6.2.159 ↗