Temperature development in structural stainless steel sections exposed to fire
Source abstract
Abstract
Abstract The initial material cost of structural stainless steel is about four times that of structural carbon steel, due largely to the expense of the alloying elements and the relatively low volume of production. Given broadly similar structural performance, additional areas of benefit need to be identified and exploited in order to establish stainless steel as a viable alternative material for construction. In addition to the familiar benefits of corrosion resistance, low maintenance, high residual value and aesthetics, one such area is fire resistance. The mechanical and thermal properties of stainless steel differ from those of carbon steel due to variation in chemical composition between the materials. A comparison of these properties for austenitic stainless steel with those for structural carbon steel is presented herein, and implications of the differences explored. Accurate and efficient determination of the temperature development within a structural member upon subjection to fire is paramount. In this paper, comparisons of temperature development in structural stainless steel sections are made between existing test results, numerical simulations and the simple calculation model of Eurocode 3: Part 1.2. Based on these comparisons, revised values for the heat transfer coefficient and emissivity of structural stainless steel members exposed to fire are proposed. In the temperature development calculation model of EN 1993-1-2, it is proposed that emissivity be taken as 0.2 (in place of the currently adopted value of 0.4) and the heat transfer coefficient be taken as 35 W/m 2 K (in place of the currently adopted value of 25 W/m 2 K). The significance of such revisions to the fire resistance and critical temperature is assessed. Application of the revised values in the predictive models for member resistances at elevated temperatures in Eurocode 3: Part 1.2 also reveals improved agreement with test results on axially loaded stainless steel columns in fire, and average enhancements in fire resistance of 10%.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fire effects on concrete materials · Structural Load-Bearing Analysis · Structural Behavior of Reinforced Concrete
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (27)
Show source-provided references
1. Structural fire design: core or specialist subject?
2. Temperature–time analysis for steel structures under fire conditions10.12989/sem.1998.6.3.275 ↗
3. Ala-Outinen T, Oksanen T. Stainless steel compression members exposed to fire. VTT Research Notes 1864, Espoo, Finland, 1997.
4. Baddoo NR, Burgan BA. Fire resistance design of austenitic stainless steel. Paper no. 243. Second world conference on steel structures, San Sebastian, May 1998.
5. Baddoo NR, Gardner L. Member behaviour at elevated temperatures: work package 5.2. ECSC project ‘development of the use of stainless steel in construction’. Contract no. 7210 SA/842. The Steel Construction Institute, UK, 2000.
6. Gardner L, Baddoo NR. Fire testing and design of stainless steel structures. J Constr Steel Res, in press.
7. An analysis of the global structural behaviour of the Cardington steel-framed building during the two BRE fire tests10.1016/S0141-0296(98)00127-8 ↗
8. Composite beams with partial fire protection10.1016/S0379-7112(97)00000-3 ↗
9. Parker AJ, Beitel JJ, Iwankiw NR. Fire protection materials for architecturally exposed structural steel (AESS). Structure Magazine, National Council of Structural Engineers Association. February 2005, p. 33–6.
10. The use of stainless steel in structures10.1002/pse.190 ↗
11. Drysdale · 1985
12. EN 1993-1-2. Eurocode 3: design of steel structures—part 1.2: general rules—structural fire design. CEN, 2005.
13. Design Manual for Structural Stainless Steel, Building series, vol. 3, 2nd ed. Euro Inox and the Steel Construction Institute, 2002.
14. EN 10088-1. Stainless steels—part 1: list of stainless steels. CEN, 1995.
15. EN 10088-2. Stainless steels—part 2: technical delivery conditions for sheet/plate and strip for general purposes. CEN, 1995.
16. ISO 834-1. Fire-resistance tests—elements of building construction—part 1: general requirements. International Organization for Standardization, Geneva, 1999.
17. EN 1991-1-2. Eurocode 1: actions on structures—part 1.2: general actions—actions on structures exposed to fire. CEN, 2002.
18. Calculation of the heating rate of an unprotected steel member in a standard fire resistance test10.1016/S0379-7112(96)00016-1 ↗
19. Ala-Outinen T. Fire resistance of stainless steel structures. Proceedings of the second european conference on steel structures (Eurosteel 1999). Prague, Czech Republic, 26–29 May, 1999. p. 165–8.
20. Towards harmonised standard fire resistance testing10.1016/S0379-7112(96)00054-9 ↗
21. ABAQUS. ABAQUS/Standard user's manual, vols. I–III and ABAQUS CAE Manual. Version 6.4. Pawtucket, USA: Hibbitt, Karlsson & Sorensen, Inc.; 2003.
22. Wang HB. Heat transfer analysis of components of construction exposed to fire. PhD thesis, Department of Civil Engineering and Construction, University of Salford, Manchester, 1995.
23. Thermal performance of cold-formed thin-walled steel panel systems in fire10.1016/S0379-7112(02)00090-5 ↗
24. A numerical study of large deflection behaviour of restrained steel beams at elevated temperatures10.1016/j.jcsr.2003.09.005 ↗
25. Heat transfer analysis of the composite slab in the Cardington frame fire tests10.1016/S0379-7112(01)00041-8 ↗
26. Calibration of Eurocode 1: actions on structures—part 1.2: actions on structures exposed to fire
27. ENV 1993-1-2. Eurocode 3: design of steel structures—part 1.2: general rules—structural fire design. CEN, 2001.