Structural response of a steel-frame building to horizontal and vertical travelling fires in multiple floors
Source abstract
Abstract
During previous fire events such as the World Trade Centre Towers (WTC) 1, 2 & 7 in New York (2001), the Windsor Tower in Madrid (2005), and the Plasco building in Iran (2017), flames were observed to travel horizontally across the floor plate and vertically to different floors. Such fires are not considered as part of the traditional prescriptive structural design for fire. Recently, the Travelling Fires Methodology (TFM) has been developed to account for such horizontally travelling nature of fires. A dozen of studies have investigated the structural response of steel, concrete, and composite structures to a single-floor travelling fire. 5 out of 6 of the vertically travelling fire studies have been limited to the structures with a long span composite truss system as in the WTC Towers. The aim of this work is to investigate the response of a substantially different structural system, i.e. a generic multi-storey steel frame, subjected to travelling fires in multiple floors, and varying the number of fire floors, including horizontal and vertical fire spread. A two-dimensional 10-storey 5-bay steel frame is modelled in the finite element software LS-DYNA. The number of multiple fire floors is varied between 1 and 10, and for each of these scenarios, 5 different fire types are investigated. They include four travelling fire scenarios and the standard fire. In total, 51 fire simulations are considered. The development of deflections, axial forces, bending moments and frame utilization are analysed. Results show that the largest stresses develop in the fire floors adjacent to cool floors, and their behaviour is independent of the number of fire floors. Results indicate that both the fire type and the number of fire floors have a significant effect on the failure time (i.e. exceeded element load carrying capacity) and the type of collapse mechanism. In the cases with a low number of fire floors (1–3) failure is dominated by the loss of material strength, while in the cases with larger number of fire floors (5–10) failure is dominated by thermal expansion. Collapse is mainly initiated by the pull-in of external columns (1–3-floor fires; 1–9-floor fires for 2.5% TFM) or swaying of the frame to the side of fire origin (5–10-floor fires). This study has assessed a different structural form compared to previous literature under an extensive range of multiple floor travelling fire scenarios. We find that although vertically travelling fires result in larger beam axial forces and initial deflections, simultaneous travelling fires result in shorter failure times and represent a more onerous scenario for the steel frame investigated. • Response of a generic steel frame subjected to travelling fires in multiple floors. • The largest stresses develop in the fire floors adjacent to cool floors. • Both the fire type and the number of fire floors have a significant effect on failure. • Simultaneous travelling fires represent a more onerous scenario for the steel frame.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Fire dynamics and safety research · Fire effects on concrete materials · Structural Response to Dynamic Loads
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (30)
Show source-provided references
1. British Steel, The Behaviour of Multi-Storey Steel Framed Buildings in Fire, Rotherham, 1999.
2. How did the WTC towers collapse: a new theory10.1016/S0379-7112(03)00069-9 ↗
3. Kirby · 1998
4. Reconstruction of the fires and thermal environment in World Trade Center buildings 1, 2, and 710.1007/s10694-012-0288-3 ↗
5. Structural response of tall buildings to multiple floor fires10.1061/(ASCE)0733-9445(2007)133:12(1719) ↗
6. Travelling fires for structural design–part I: literature review10.1016/j.firesaf.2012.06.003 ↗
7. Travelling fires for structural design-Part II: design methodology10.1016/j.firesaf.2012.06.011 ↗
8. Improved formulation of travelling fires and application to concrete and steel structures10.1016/j.istruc.2015.06.001 ↗
9. Structural response of a MRF exposed to travelling fire10.1680/jstbu.14.00046 ↗
10. E. Rackauskaite, P. Kotsovinos, A. Jeffers, G. Rein, Structural response of a generic steel frame exposed to travelling fires, Proceedings of the 9th International Conference on Structures in Fire, pp. 975–982, 2016.
11. The influence of travelling fires on a concrete frame10.1016/j.engstruct.2011.01.034 ↗
12. Law · 2010
13. Röben · 2009
14. Kotsovinos · 2013
15. Structural behaviour during a vertically travelling fire10.1016/j.jcsr.2009.08.007 ↗
16. Tall building collapse mechanisms initiated by fire: mechanisms and design methodology10.1016/j.engstruct.2011.10.003 ↗
17. The World Trade Center 9/11 disaster and progressive collapse of tall buildings10.1007/s10694-012-0283-8 ↗
18. Sadek · 2010
19. S.E. Quiel, M.E.M. Garlock, 3-D versus 2-D modeling of a high-rise steel framed building under fire, Proceedings of the 5th International Conference on Structures in Fire (SiF’08), pp. 278–289, 2008.
20. Flint · 2005
21. CEN, EN 1991-1-2:2002 - Eurocode 1. Actions on structures. General actions. Actions on structures exposed to fire, 2002.
22. Buchanan · 2001
23. Recent developments and applications in structural fire engineering design—A review10.1016/0379-7112(86)90060-3 ↗
24. CEN, EN 1993-1-2:2005 - Eurocode 3. Design of steel structures. General rules. Structural fire design, 2005.
25. Incropera · 2007
26. Model parameter sensitivity and benchmarking of the explicit dynamic solver of LS-DYNA for structural analysis in case of fire10.1016/j.firesaf.2017.03.002 ↗
27. Hallquist · 2006
28. CEN, EN 1993-1-1:2005 - Eurocode 3. Design of steel structures. General rules and rules for buildings, 2005.
29. A performance based methodology for fire design of restrained steel beams10.1016/j.jcsr.2010.09.004 ↗
30. Plastic axial load and moment interaction curves for fire-exposed steel sections with thermal gradients10.1061/(ASCE)0733-9445(2008)134:6(874) ↗