journal article·2022-07Open access

Interventional Microbubble Enhanced Sonothrombolysis on Left Ventricular Assist Devices

Xiaobing Zheng, Yunfan Pan, Yuan Zhang, Kuilin Meng, Jianye Zhou, Xin Wang, Yongchun Cui, Jiang Li, Yongjian Li, Haosheng Chen

Advanced Science· Volume 9· Issue 21

Abstract

Abstract The left ventricular assist device (LVAD) is often used in the treatment of heart failure. However, 4% to 9% implanted LVAD will have thrombosis problem in one year, which is fatal to the patient's life. In this work, an interventional sonothrombolysis (IST) method is developed to realize the thrombolysis on LVAD. A pair of ultrasound transducer rings is installed on the shell of LVAD, and drug‐loaded microbubbles are injected into the LVAD through the interventional method. The microbubbles are adhere on the thrombus with the coated thrombus‐targeted drugs, and the thrombolytic drugs carried by the bubbles are brought into the thrombus by the cavitation of bubbles under the ultrasound. In a proof‐of‐concept experiment in a live sheep model, the thrombus on LVAD is dissolved in 30 min, without damages on LVADs and organs. This IST exhibits to be more efficient and safer compared with other thrombolysis methods on LVAD.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Mechanical Circulatory Support Devices · Cardiac Arrest and Resuscitation · Cardiac Structural Anomalies and Repair

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

State Key Laboratory of Tribology Department of Mechanical Engineering Tsinghua University Beijing 100084 China

School of Mechanical Engineering University of Science and Technology Beijing Beijing 100083 China

Animal Experiment Center Fuwai Hospital Chinese Academy of Medical Sciences Beijing 100037 China

References (36)

Show source-provided references
1. 10.1161/CIRCULATIONAHA.111.05841210.1161/CIRCULATIONAHA.111.058412 ↗
2. 10.1093/ejcts/ezaa18010.1093/ejcts/ezaa180 ↗
3. 10.1016/j.jacc.2016.03.57310.1016/j.jacc.2016.03.573 ↗
4. 10.1016/j.ultrasmedbio.2020.10.01010.1016/j.ultrasmedbio.2020.10.010 ↗
5. 10.1126/sciadv.aaz820410.1126/sciadv.aaz8204 ↗
6. 10.1016/j.biomaterials.2018.12.02310.1016/j.biomaterials.2018.12.023 ↗
7. 10.1038/s41598-017-03492-410.1038/s41598-017-03492-4 ↗
8. 10.1038/s41378-020-00228-910.1038/s41378-020-00228-9 ↗
9. 10.1126/sciadv.abf903310.1126/sciadv.abf9033 ↗
10. IEC 61157–2007 International Electrotechnical Commission Geneva Switzerland2007.
11. Stride E. · Nat. Rev. Phys. · 2019
12. 10.1038/nature0161310.1038/nature01613 ↗
13. 10.1038/s41551-018-0258-210.1038/s41551-018-0258-2 ↗
14. 10.1016/j.healun.2011.08.02210.1016/j.healun.2011.08.022 ↗
15. 10.1126/sciadv.aaz901410.1126/sciadv.aaz9014 ↗
16. 10.1016/j.ultrasmedbio.2021.07.01810.1016/j.ultrasmedbio.2021.07.018 ↗
17. 10.1016/j.athoracsur.2020.03.06110.1016/j.athoracsur.2020.03.061 ↗
18. 10.1016/j.healun.2013.11.00210.1016/j.healun.2013.11.002 ↗
19. 10.1177/204887261668841810.1177/2048872616688418 ↗
20. 10.1016/j.healun.2013.12.00110.1016/j.healun.2013.12.001 ↗
21. 10.21037/jtd.2018.01.11510.21037/jtd.2018.01.115 ↗
22. 10.1177/039139881987629310.1177/0391398819876293 ↗
23. 10.1097/MAT.000000000000083310.1097/MAT.0000000000000833 ↗
24. 10.1016/j.athoracsur.2019.03.09010.1016/j.athoracsur.2019.03.090 ↗
25. 10.1097/MAT.000000000000092810.1097/MAT.0000000000000928 ↗
26. 10.1055/s-0036-159386710.1055/s-0036-1593867 ↗
27. 10.1111/aor.1312510.1111/aor.13125 ↗
28. 10.1016/j.avsg.2020.08.12810.1016/j.avsg.2020.08.128 ↗
29. Krajcer Z. · J. Endovasc. Ther. · 2002 · 9 · 756
30. 10.1016/S1051-0443(99)70220-410.1016/S1051-0443(99)70220-4 ↗
31. 10.1007/s00270990019110.1007/s002709900191 ↗
32. 10.1016/j.jvs.2020.03.03210.1016/j.jvs.2020.03.032 ↗
33. 10.1161/01.CIR.0000066693.22220.3010.1161/01.CIR.0000066693.22220.30 ↗
34. 10.1161/01.CIR.99.1.2610.1161/01.CIR.99.1.26 ↗
35. 10.1055/s-2008-102721610.1055/s-2008-1027216 ↗
36. Hao C. · Biomed. Rep. · 2018 · 8 · 77