Predicting Mechanical Strength of In-Use Firefighter Protective Clothing Using Near-Infrared Spectroscopy
Source abstract
Abstract
The exact lifespan of in-use firefighter protective clothing is difficult to predict due to the large variations in use between individual garments. Furthermore, testing methods used to evaluate new protective clothing are destructive in nature and could not be applied to in-use garments. Various non-destructive techniques have been proposed for the evaluation of in-use clothing, each possessing its own advantages and disadvantages. The ability of near-infrared spectroscopy to predict the tensile strength of thermally aged fabrics used in protective clothing for wildland firefighters and other workers is investigated here. Fabrics were exposed to heat fluxes from 10 kW/m2 to 40 kW/m2 for various durations using the cone calorimeter, after which the tensile strength of the fabrics was measured. Temperatures measured during the exposures and results of thermal gravimetric analysis tests were used to interpret changes in tensile strength. Multivariate linear regression was used to develop correlations between the tensile strength and the reflectance values measured between 1500 nm and 2500 nm for new and thermally aged fabrics. It was found that models based on reflectance measurements made at as few as three wavelengths could be used to estimate the tensile strength of the thermally aged specimens.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Textile materials and evaluations · Thermoregulation and physiological responses · Wood Treatment and Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (28)
Show source-provided references
1. Rezazadeh M (2014) Evaluation of performance of in-use firefighters’ protective clothing using non-destructive tests, Dissertation, University of Saskatchewan
2. Canadian General Standards Board (2001) CAN/CGSB-155.1-2001 Firefighter’s protective clothing for protection against heat and flame. Standards Council of Canada, Ottawa
3. National Fire Protection Association (2013) NFPA 1971 Standard on protective ensemble of structural firefighting. National Fire Protection Association, Quincy
4. National Fire Protection Association (2014) NFPA 1851 Standard on selection, care, and maintenance of structural firefighting protective ensembles. National Fire Protection Association, Quincy
5. Lion Apparel (2005) User instruction, safety and training guide. Lion Apparel, Dayton
6. Vogelpohl TL (1996) Post-use evaluation of firefighter’s turnout coats. Thesis, University of Kentucky
7. Rezazadeh M, Torvi D (2010) Assessment of factors affecting the continuing performance of firefighters’ protective clothing: a literature review. Fire Technology 47:565–59910.1007/s10694-010-0188-3 ↗
8. Washer G, Brooks T, Saulsberry R (2009) Characterization of Kevlar using Raman spectroscopy. Journal of Materials in Civil Engineering 21:226–23410.1061/(ASCE)0899-1561(2009)21:5(226) ↗
9. Thorpe P (2004) Assessment of in-use firefighter’s protective clothing. Thesis, University of Saskatchewan
10. Nazare S, Davis RD, Peng JS, Chin J (2012) Accelerated weathering of firefighter protective clothing: delineating the impact of thermal, moisture, and ultraviolet light exposures. NIST technical note 1746. National Institute of Standards and Technology, Gaithersburg
11. Arrieta C, David E, Dolez P, Vu-Khanh T (2010) Thermal aging of a blend of highperformance fibres Journal of Applied Polymer Science 93:3031–303910.1002/app.30825 ↗
12. Gralewicz G, Wiecek B (2009) Active thermography in qualitative evaluation of protective materials. Int J Occup Saf Ergon15: 363–37110.1080/10803548.2009.11076816 ↗
13. Jain A, Vijayan K (2002) Thermally induced structural changes in Nomex fibres. Bull Mater Sci 25:341–34610.1007/BF02704129 ↗
14. Slater K (1986) The progressive deterioration of textile materials, part I: characteristics of degradation. J Text Inst 77(2):76–8710.1080/00405008608658396 ↗
15. Rezazadeh M, Torvi D (2012) Non-destructive test methods to assess the level of damage to firefighters’ protective clothing. In: AM Shepherd (Ed.) STP 1544 performance of protective clothing and equipment, emerging issues and technologies. ASTM International, West Conshohocken, pp 202–22610.1520/STP104097 ↗
16. Sherman Hsu CP (1997) Infrared spectroscopy. In: FA Settle (Ed.) Handbook of instrumental techniques for analytical chemistry. Prentice Hall, Englewood Cliffs, pp 247–283
17. Mora CR (2009) Rapid techniques for screening wood properties in forest plantations. Dissertation, University of Georgia
18. Kludt KD (2003) Use of near infrared spectroscopy technology for predicting bending properties of clear wood specimens. Thesis, Washington State University
19. Hedrick SE, Bennett RM, Rials TG, Kelley, SS (2007) Correlation of near-infrared spectroscopy measurements with the properties of treated wood. J Mater Civ Eng 19:279–28510.1061/(ASCE)0899-1561(2007)19:4(279) ↗
20. Kelley SS (2003) Method of predicting mechanical properties of decayed wood. Patent No. US 6,593572 B2
21. EI DuPont de Nemours and Company (2001) Technical guide for Nomex® brand fibre H-52720. EI DuPont de Nemours and Company, Richmond
22. Torvi DA, Rezazadeh M, Bespflug C (2016) Effects of convective and radiative heat sources on thermal response of single- and multiple-layer protective fabrics in benchtop tests. In: B Shiels, K Lehtonen (Eds.) STP 1593 performance of protective clothing and equipment: risk reduction through research and testing. ASTM International, West Conshohocken, pp 131–15810.1520/STP159320160013 ↗
23. JH Veghte (1988) Fire fighter’s protective clothing: design criteria, 2nd edition. Lion Apparel, Dayton
24. ASTM International (2013) ASTM D5034-09: standard test method for breaking strength and elongation of textile fabrics (grab test). ASTM International, West Conshohocken
25. Torvi DA, Dale JD (1999) Heat transfer in thin fibrous materials under high heat flux conditions. Fire Technol 35:210–23110.1023/A:1015484426361 ↗
26. Iyer RV, Sudhakar A, Vijayan K (2006) Decomposition behaviour of Kevlar 49 fibres: part II. At T values < Td. High Perform Polym 18:495–51710.1177/0954008306066540 ↗
27. Rossi RM, Bolli W, Stampfli R (2008) Performance of firefighter’s protective clothing after heat exposure. Int J Occup Saf Ergon 14:55–6010.1080/10803548.2008.11076747 ↗
28. Schwanninger M, Rodrigues JC, Fackler K (2011) A review of band assignments in near infrared spectra of wood and wood components. J Near Infrared Spectrosc 19:287–30810.1255/jnirs.955 ↗