Performance of Timber Connections Exposed to Fire: A Review
Source abstract
Abstract
Fire safety has always been a major concern in the design of timber construction. Even though wood is a highly combustible material, timber members can perform adequately under elevated temperatures. The thermal response of timber connections, however, is in most cases poor and determination of their fire resistance is usually the crucial factor in evaluating the overall load-bearing capacity of wood structures exposed to fire. The analysis of timber joints under fire conditions can be challenging due to their complexity and variety. After presenting the variation of the properties of timber with temperature, this paper reviews the fire performance of various connection types, such as bolted or nailed wood-to-wood and steel-to-timber joints. Results from relevant experimental programs and numerical studies are discussed in detail and future research needs are highlighted. The effect of several factors on the fire resistance of timber connections, such as the fastener diameter, timber thickness and joint geometry, is investigated and useful conclusions are drawn. Based on these, preliminary guidelines for the efficient design of timber connections under fire exposure are presented. © 2013 Springer Science+Business Media New York.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fire effects on concrete materials · Fire dynamics and safety research · Wood Treatment and Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (43)
Show source-provided references
1. ISO 834-1 (1999) Fire-resistance tests—elements of building construction—part 1: general requirements. ISO, Switzerland
2. CAN/ULC-S101-07 (2007) Standard methods for fire endurance tests of building construction and materials. Laboratories of Canada, Ottawa
3. Mehaffey JR, Cuerrier P, Carisse G (1994) A model for predicting heat transfer through gypsum board/wood stud walls exposed to fire. Fire Mater 18:297–305. doi: 10.1002/fam.81018050510.1002/fam.810180505 ↗
4. Janssens ML (1994) Thermo-physical properties for wood pyrolysis models. In: Pacific timber engineering conference, Gold Coast, Australia
5. Knudson RM (1973) Performance of structural wood members exposed to fire. PhD dissertation, University of California, Berkeley, USA
6. Fredlund B (1993) Modelling of heat and mass transfer in timber structures during fire. Fire Saf J 20:39–6910.1016/0379-7112(93)90011-E ↗
7. Konig J, Walleij L (2000) Timber frame assemblies exposed to standard and parametric fires, part 2: a design model for standard fire exposure. Rapport I 0001001. Swedish Institute for Wood Technology Research, Stockholm
8. Lie TT (1992) Structural fire protection. ASCE manuals and reports of engineering practice, no. 78. American Society of Civil Engineers, New York10.1061/9780872628885 ↗
9. Takeda H, Mehaffey JR (1998) WALL2D: a model for predicting heat transfer through wood-stud walls exposed to fire. Fire Mater 22:133–14010.1002/(SICI)1099-1018(1998070)22:4<133::AID-FAM642>3.0.CO;2-L ↗
10. EN 1995-1-2 (2009) Eurocode 5—design of timber structures part 1–2: general rules—structural fire design. CEN, Brussels
11. Peng L, Hadjisophocleous G, Mehaffey J, Mohammad M (2011) Predicting the fire resistance of wood–steel–wood connections. Fire Technol 47:1101–1119. doi: 10.1007/s10694-009-0118-410.1007/s10694-009-0118-4 ↗
12. EN 1993-1-2 (2005) Eurocode 3—design of steel structures part 1–2: general rules—structural fire design. CEN, Brussels
13. Erchinger C, Frangi A, Fontana M (2010) Fire design of steel-to-timber dowelled connections. Eng Struct 32:580–589. doi: 10.1016/j.engstruct.2009.11.00410.1016/j.engstruct.2009.11.004 ↗
14. Buchanan AH (2001) Structural design for fire safety. Wiley, Chichester
15. Peng L, Hadjisophocleous G, Mehaffey J, Mohammad M (2012) Fire performance of timber connections, part 1: fire resistance tests on bolted wood–steel–wood and steel–wood–steel connections. J Struct Fire Eng 3(2):107–131. doi: 10.1260/2040-2317.3.2.10710.1260/2040-2317.3.2.107 ↗
16. Lau PH (2006) Fire resistance of connections in laminated veneer lumber (LVL). MEFE thesis, Department of Civil Engineering, University of Canterbury
17. Chuo TCB (2007) Fire performance of connections in laminated veneer lumber. MEFE thesis, Department of Civil Engineering, University of Canterbury
18. Dhima D (1999) Verification expérimentale de la résistance au feu des assemblages d’ éléments en bois. CTICM Ref. INC-99/399-DD/NB, CTICM, Paris, France
19. Laplanche K (2006) Etude du comportement au feu des assemblages de structures bois: Approche expérimentale et modélisation. Thèse doctorale, Université Blaise Pascal – Clermont II
20. Peng L, Hadjisophocleous G, Mehaffey J, Mohammad M (2010) Fire resistance of wood–steel–wood connections. In: Sixth international conference on structures in fire, East Lansing, USA, June 2–4, 2010
21. Ayme N (2003) Assemblages bois-métal en double cisaillement. Rapport Du Comportement Au Feu D’ Assemblages Bois, CTICM Ref.SR21-03/121-NA/PB, CTICM, Paris, France
22. Peng L, Hadjisophocleous G, Mehaffey J, Mohammad M (2010) Fire resistance performance of unprotected wood–wood–wood and wood–steel–wood connections: a literature review and new data correlations. Fire Saf J 45:392–399. doi: 10.1016/j.firesaf.2010.08.00310.1016/j.firesaf.2010.08.003 ↗
23. König J (2005) Structural fire design according to Eurocode 5—design rules and their background. Fire Mater 29:147–163. doi: 10.1002/fam.87310.1002/fam.873 ↗
24. König J (2005) Structural fire design of timber structures according to Eurocode 5. Fire Saf Sci 8:303–313. doi: 10.3801/IAFSS.FSS.8-30310.3801/IAFSS.FSS.8-303 ↗
25. Austruy C (2007) Fire resistance of timber connections. http://perso.crans.org/austruy/rapport%20latex/rapportlatex.pdf . Assessed on 7 June 2013.
26. EN 1995-1-1 (2006) Eurocode 5: design of timber structures—part 1-1: general—common rules and rules for buildings. CEN, Brussels
27. Dias de Moraes P, Rodrigues JPC, Correia NDF (2012) Behavior of bolted timber joints subjected to high temperature. Eur J Wood Wood Prod 70:225–232. doi: 10.1007/s00107-011-0539-x10.1007/s00107-011-0539-x ↗
28. Moss PJ, Nilsen TM, Fragiacomo M, Buchanan AH (2010) Fire resistance of connections in timber structures. In: Sixth international conference on structures in fire, East Lansing, USA, June 2–4, 201010.1201/b10571-88 ↗
29. Correia ND, Rodrigues JPC, Moraes PD (2010) Timber bolted joints subjected to high temperatures. In: Sixth international conference on structures in fire, East Lansing, USA, June 2–4, 2010
30. Manriquez MJ (2008) Influence of the temperature on the mechanical resistance of the Pariacá. MSc thesis, Federal University of Santa Catarina, Florianopólis, Brazil
31. Noren J (1996) Load-bearing capacity of nailed joints exposed to fire. Fire Mater 20:133–14310.1002/(SICI)1099-1018(199605)20:3<133::AID-FAM565>3.0.CO;2-3 ↗
32. Moss PJ, Buchanan AH, Fragiacomo M, Austruy C (2010) Experimental testing and analytical prediction of the behavior of timber bolted connections subjected to fire. Fire Technol 46:129–148. doi: 10.1007/s10694-009-0096-610.1007/s10694-009-0096-6 ↗
33. EN 1194:1999 (1999) Timber structures—glued laminated timber—strength classes and determination of characteristic values. CEN, Brussels
34. Standards New Zealand NZS 3603:1993 (1993) Timber structures standard. SNZ, Wellington
35. CAN/CSA-O86-09 (2009) Engineering design in wood. Canadian Standards Association, Rexdale
36. Racher P, Laplanche K, Dhima D, Bouchaïr A (2010) Thermo-mechanical analysis of the fire performance of dowelled timber connection. Eng Struct 32:1148–1157. doi: 10.1016/j.engstruct.2009.12.04110.1016/j.engstruct.2009.12.041 ↗
37. Cachim PB, Franssen JM (2009) Numerical modeling of timber connections under fire loading using a component model. Fire Saf J 44:840–853. doi: 10.1016/j.firesaf.2009.03.01310.1016/j.firesaf.2009.03.013 ↗
38. Frangi A, Erchinger C, Fontana M (2010) Experimental fire analysis of steel-to-timber connections using dowels and nails. Fire Mater 34:1–19. doi: 10.1002/fam.99410.1002/fam.994 ↗
39. Audebert M, Dhima D, Taazount M, Bouchaïr A (2011) Numerical investigations on the thermo-mechanical behavior of steel-to-timber joints exposed to fire. Eng Struct 33:3257–3268. doi: 10.1016/j.engstruct.2011.08.02110.1016/j.engstruct.2011.08.021 ↗
40. Audebert M, Dhima D, Taazount M, Bouchaïr A (2012) Behavior of dowelled and bolted steel-to-timber connections exposed to fire. Eng Struct 39:116–125. doi: 10.1016/j.engstruct.2012.02.01010.1016/j.engstruct.2012.02.010 ↗
41. Peng L, Hadjisophocleous G, Mehaffey J, Mohammad M (2012) Fire performance of timber connections, part 2: thermal and structural modelling. J Struct Fire Eng 3(2):133–153. doi: 10.1260/2040-2317.3.2.13310.1260/2040-2317.3.2.133 ↗
42. Erchinger C, Frangi A, Mischler A (2006) Thermal investigations on multiple shear steel-to-timber connections. In: WTCE 2006 9th world conference on timber engineering, Portland, OR, USA, August 6–10, 2006
43. Buchanan AH, King AH (1991) Fire performance of gusset connections in glue-laminated timber. Fire Mater 15:137–14310.1002/fam.810150306 ↗