Experimental Study on Flame Length of Sidewall Fire with Different Aspect Ratios and Orientations in an Arched Tunnel
Source abstract
Abstract
In this study, a series of sidewall fire experiments were carried out in an arched tunnel, and the effect brought by the fire source height, the shape and the orientation of oil pool on flame length and transverse temperature were investigated. The results show that when the long side of oil pool is parallel to sidewall, the height change of oil pool has less influence on flame under the arched ceiling, while it has a large influence under the horizontal ceiling in previous studies; when the long side of oil pool is perpendicular to sidewall, the flame bifurcates with a large aspect ratio and entrains more fresh air, and the mass loss rate increases dramatically. The height change of oil pool has less influence on the flame when the long side of oil pool is parallel to sidewall, while it has great influence when the long side of oil pool is perpendicular to sidewall. Besides, the dimensionless heat release rates of fire source are modified and the flame length formulas are obtained under the two orientations of oil pool. The equation of the transverse temperature distribution under arched ceiling was obtained by modifying the lateral travelling distance of the plume.
Source: expertdata · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fire dynamics and safety research · Fire effects on ecosystems · Evacuation and Crowd Dynamics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (21)
Show source-provided references
1. Ji J, Fan CG, Li YZ, Ingason H, Sun JH (2015) Experimental study of non-monotonous sidewall effect on flame characteristics and burning rate of n-heptane pool fires. Fuel 145:228–23310.1016/j.fuel.2014.12.085 ↗
2. Gao ZH, Ji J, Wan HX, Li KY, Sun JH (2015) An investigation of the detailed flame shape and flame length under the ceiling of a channel. Proc Combust Inst 35(3):2657–266410.1016/j.proci.2014.06.078 ↗
3. Hasemi Y, Nishihata M (1989) Fuel shape effect on the deterministic properties of turbulent diffusion flames. Bull JPN Assn Fire Sci Eng 38(2):29–34
4. Ji J, Tan TT, Gao ZH, Wan HX (2019) Influence of sidewall and aspect ratio on burning behaviors of rectangular ethanol and heptane pool fires. Fuel 238:166–17210.1016/j.fuel.2018.10.112 ↗
5. Fan CG, Ji J, Li YZ, Ingason H, Sun JH (2017) Experimental study of sidewall effect on flame characteristics of heptane pool fires with different aspect ratios and orientations in a channel. Proc Combust Inst 36(2):3121–312910.1016/j.proci.2016.06.196 ↗
6. Liu X, Zhu GQ, Pan RL, Xu G, He L (2021) Experimental study on wall fire behavior produced by n-heptane pools with different aspect ratios and orientations in arched tunnel. Case Stud Therm Eng 28:10143810.1016/j.csite.2021.101438 ↗
7. Pan RL, Zhu GQ, Liang ZH, Zhang GW, Liu HN, Zhou X (2020) Experimental study on the fire shape and maximum temperature beneath ceiling centerline in utility tunnel under the effect of curved sidewall. Tunn Undergr Sp Technol 99:20330410.1016/j.tust.2020.103304 ↗
8. Pan RL, Zhu GQ, Xu G, Liu X (2021) Experimental analysis on burning rate and temperature profile produced by pool fire in a curved tunnel as a function of fire location. Process Saf Environ 152:549–56710.1016/j.psep.2021.06.039 ↗
9. Pan RL, Hostikka S, Zhu GQ, Xu G, Liu X (2022) Two-dimensional analysis on ceiling jet temperature characteristics in a semicircular tunnel. Fire Technol 58:959–99010.1007/s10694-021-01185-z ↗
10. Ji J, Fu YY, Li KY, Sun JH, Fan CG, Shi WX (2015) Experimental study on behavior of sidewall fires at varying height in a corridor-like structure. Proc Combust Inst 35(3):2639–264610.1016/j.proci.2014.06.041 ↗
11. Tang F, Zhu YT, Chen L, Sun XP, McNamee M, Hees PV, Hu LH (2020) Experimental study and analysis of radiation heat fluxes received by a floor beneath an inclined ceiling. Fire Mater 45(2):205–21410.1002/fam.2925 ↗
12. Utiskul Y, Quintiere J (2008) An application of mass loss rate model with fuel response effects in fully-developed compartment fires. Fire Saf Sci 9:827–83810.3801/IAFSS.FSS.9-827 ↗
13. Zhang XC, Tao HW, Xu WB, Liu XZ, Li XD, Zhang XL (2017) Flame extension lengths beneath an inclined ceiling induced by rectangular-source fires. Combust Flame 176:349–35710.1016/j.combustflame.2016.11.004 ↗
14. Pan RL, Zhu GQ, Xu G, Liu X (2022) Experimental and theoretical analysis on extension flame length of buoyancy-induced fire plume beneath the curved ceiling. Tunn Undergr Space Technol 122:10436510.1016/j.tust.2022.104365 ↗
15. Yan WG, Wang CJ, Guo J (2012) One extended OTSU flame image recognition method using RGBL and stripe segmentation. Appl Mech Mater 121:2141–2145
16. Zukoski EE, Cetegen BM, Kubota T (1985) Visible structure of buoyant diffusion flames. Symp Int Combust 20(1):361–36610.1016/S0082-0784(85)80522-1 ↗
17. An W (2015) Investigation of combustion and flame spread behaviors of PS insulation materials applying to building exterior wall. University of Science and Technology of China, Beijing
18. You HZ, Faeth GM (1981) An investigation of fire impingement on a horizontal ceiling. Penn State University, Pennsylvania
19. Gao ZH, Ji J, Wan HX, Zhu JP, Sun JH (2017) Experimental investigation on transverse ceiling flame length and temperature distribution of sidewall confined tunnel fire. Fire Saf J 91:371–37910.1016/j.firesaf.2017.04.033 ↗
20. Kung HC, Spaulding RD, Stavrianidis P (1991) Fire induced flow under a sloped ceiling. Fire Saf Sci 3:271–28010.3801/IAFSS.FSS.3-271 ↗
21. Oka Y, Imazeki O, Sugawa O (2010) Temperature profile of ceiling jet flow along an inclined unconfined ceiling. Fire Saf J 45(4):221–22710.1016/j.firesaf.2010.03.003 ↗