Numerical Simulations of Gas Burner Experiments in a Residential Structure with HVAC System
Source abstract
Abstract
Abstract Controlled fire experiments using a gas burner were previously conducted in a purpose-built, two-story, moderately air-tight residential structure to understand the effect of a heating, ventilating, and air conditioning (HVAC) system and door positions on the fire-induced environment. Temperatures, gas concentrations (oxygen, water vapor, carbon dioxide), and differential pressures were monitored throughout the structure. HVAC status (off vs. on) and stairwell door position of the fire room (open vs. closed) were varied for the experiments analyzed in this paper. In this study, Fire Dynamics Simulator (FDS) v. 6.7.9 was used to simulate these experiments. Experimental data quantifying the air tightness of the building and cold flowrates through HVAC vents were determined to be important to optimize leakages and HVAC loss coefficients for the simulation setup. Pressure development in the structure was predicted correctly to be higher on the first floor and lower in the basement, but the magnitude of steady-state pressure was underpredicted. The measured and predicted steady-state temperature distributions were statistically different for the cases with and without the HVAC on, regardless of the door position. FDS predicted gas transport through the HVAC duct network, and under-predicted temperature rise and water vapor content by about 9% and 10%, respectively, and over-predicted volumetric oxygen and carbon dioxide content by about 21% and 6%, respectively. Temperature rise prediction in the closed room, where the gas transport primarily occurred via the HVAC duct network, improved after including heat loss from the HVAC duct to the ambient.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Fire dynamics and safety research · Evacuation and Crowd Dynamics · Wind and Air Flow Studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (27)
Show source-provided references
1. USFA-FEMA: civilian fire fatalities in residential buildings (2017–2019). Topical Fire Report Series 21(3) (2021)
2. Hostikka S, Janardhan RK, Riaz U, Sikanen T (2017) Fire-induced pressure and smoke spreading in mechanically ventilated buildings with air-tight envelopes. Fire Saf J 91:380–388. https://doi.org/10.1016/j.firesaf.2017.04.00610.1016/j.firesaf.2017.04.006 ↗
3. Brohez S, Caravita I (2020) Fire induced pressure in airthigh houses: experiments and FDS validation. Fire Saf J 114:103008. https://doi.org/10.1016/j.firesaf.2020.10300810.1016/j.firesaf.2020.103008 ↗
4. Ghanekar S, Weinschenk C, Horn GP, Stakes K, Kesler RM, Lee T (2022) Effects of HVAC on combustion-gas transport in residential structures. Fire Saf J 128:103534. https://doi.org/10.1016/j.firesaf.2022.10353410.1016/j.firesaf.2022.103534 ↗
5. Klote JH (1999) CFD simulations of the effects of HVAC-induced flows on smoke detector response. ASHRAE Trans 105 (January), Chicago, Illinois, U.S.A, pp 395–409
6. Floyd J (2011) Coupling a network HVAC model to a computational fluid dynamics model using large eddy simulation. Fire Saf Sci. https://doi.org/10.3801/IAFSS.FSS.10-45910.3801/IAFSS.FSS.10-459 ↗
7. Ralph B, Carvel R (2018) Coupled hybrid modelling in fire safety engineering; a literature review. Fire Saf J 100(February):157–170. https://doi.org/10.1016/j.firesaf.2018.08.00810.1016/j.firesaf.2018.08.008 ↗
8. Ralph B, Carvel R, Floyd J (2019) Coupled hybrid modelling within the Fire Dynamics Simulator: transient transport and mass storage. J Build Perform Simul 12(5):685–699. https://doi.org/10.1080/19401493.2019.160830410.1080/19401493.2019.1608304 ↗
9. Humphries LL, Beeny BA, Gelbard F, Louie DL, Phillips J (2017) MELCOR computer code manuals. Technical Report Janurary, U.S. Nuclear Regulatory Commission, Washington D.C.
10. Audouin L, Rigollet L, Prétrel H, Le Saux W, Röwekamp M (2013) OECD PRISME project: fires in confined and ventilated nuclear-type multi-compartments—overview and main experimental results. Fire Saf J 62(PART B):80–101. https://doi.org/10.1016/j.firesaf.2013.07.00810.1016/j.firesaf.2013.07.008 ↗
11. Wahlqvist J, Van Hees P (2013) Validation of FDS for large-scale well-confined mechanically ventilated fire scenarios with emphasis on predicting ventilation system behavior. Fire Saf J 62(PART B):102–114. https://doi.org/10.1016/j.firesaf.2013.07.00710.1016/j.firesaf.2013.07.007 ↗
12. Quiat A (2020) Analysis of propane gas burner experiments and FDS simulations in a two-story residential structure with HVAC. PhD Thesis, University of Maryland, College Park
13. Weinschenk C, Ghanekar S, Stakes K, Quiat A, Kesslar RM, Lee T (2023) Gas burner experiments conducted in residential structure with HVAC system. Data in Brief 46 (February). https://doi.org/10.1016/j.dib.2022.10882510.1016/j.dib.2022.108825 ↗
14. Pitts WM, Braun E, Peacock RD, Mitler HE, Johnsson EL, Reneke PA, Blevins LG (2002) Temperature uncertainties for bare-bead and aspirated thermocouple measurements in fire environments. Therm Meas Found Fire Stand ASTM STP 1427:3–15. https://doi.org/10.1520/stp10945s10.1520/stp10945s ↗
15. ASTM International (2019) Standard test method for determining air leakage rate by fan pressurization. ASTM International, West Conshohocken. https://doi.org/10.1520/E0779-1910.1520/E0779-19 ↗
16. Persily AK (1998) Airtightness of commercial and institutional buildings: blowing holes in the myth of tight buildings. Thermal Envelopes VII Conference (December), Clearwater, Florida, U.S.A, pp 829–837
17. Testo 420 flow hood system—UX-30009-52. https://www.coleparmer.com/p/testo-420-flow-hood-system/72876. Accessed 15 Mar 2023
18. McGrattan KB, Hostikka S, Floyd J, McDermott R, Vanella M (2021) Fire dynamics simulator user’s guide. Technical report. National Institute of Standards and Technology, Gaithersburg. https://doi.org/10.6028/NIST.SP.1019, https://nvlpubs.nist.gov/nistpubs/Legacy/SP/nistspecialpublication1019.pdf10.6028/NIST.SP.1019 ↗
19. Tewarson A (2008) Generation of heat and chemical compounds in fires, Table 3.4.16. In: DiNenno PJ, Drysdale D, Beyler CL, Walton WD, Custer RLP, Hall JR Jr. and Watts JM Jr., SFPE handbook of fire protection engineering, 4th ed., pp 3-105–3-194
20. Salley M, Wachowiak R (2012) Nuclear power plant fire modeling application guide (NPP FIRE MAG) NUREG-1934, vol November 2012, p 305
21. R-13 EcoTouch® PINK® FIBERGLAS™ Insulation. https://insulation.owenscorning.com/homeowners/insulation/products/r-13-fiberglas-insulation/ Accessed 13 Apr 2022
22. Bergman TL, Lavine AS, Incropera FP, Dewitt DP (2018) Fundamentals of heat and mass transfer, 8th edn. Wiley, New Jersey, pp 983–995
23. Gong J, Zhou H, Zhu H, McCoy CG, Stoliarov SI (2021) Development of a pyrolysis model for oriented strand board: part II-thermal transport parameterization and bench-scale validation. J Fire Sci 39(6):477–494. https://doi.org/10.1177/0734904121103665110.1177/07349041211036651 ↗
24. USG Durock®Brand Cement Board Systems Catalog. http://www.usg.com/content/dam/USG_Marketing_Communications/united_states/product_promotional_materials/finished_assets/durock-cement-board-system-guide-en-SA932.pdf Accessed 13 Apr 2022
25. American Society of Heating, R., Air-Conditioning Engineers I (2017) 2017 ASHRAE handbook: fundamentals. American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (ASHRAE), Atlanta, pp 983–995
26. McGrattan KB, Hostikka S, Floyd J, McDermott R, Vanella M (2021) Fire dynamics simulator technical reference guide vol. 3: validation. Technical report. National Institute of Standards and Technology, Gaithersburg. https://doi.org/10.6028/NIST.SP.1018, https://nvlpubs.nist.gov/nistpubs/Legacy/SP/nistspecialpublication1018.pdf10.6028/NIST.SP.1018 ↗
27. Peacock RD, Reneke PA, Davis DW, Jones WW (1999) Quantifying fire model evaluation using functional analysis. Fire Saf J 33(3):167–184. https://doi.org/10.1016/S0379-7112(99)00029-610.1016/S0379-7112(99)00029-6 ↗