journal article·2022-01

Optimizing Smoke Alarm Signals for Those at Highest Risk for Residential Fire-Related Death: Testing the Effectiveness of Children’s Smoke Alarms for Sleeping Older Adults

Gary A. Smith, Sandhya Kistamgari, Mark Splaingard

Fire Technology· Volume 58· Issue 1
Publisher page

Abstract

To test whether alarms that are effective in awakening children and prompting their escape are also effective among older adults 60 to 84 years old. These two age groups are at highest risk of residential fire-related death. Using a randomized, non-blinded, repeated measures design, 31 older adults were exposed during the N2 or N3 sleep stages to four different smoke alarms signals: female voice, low-frequency tone, female voice combined with low-frequency tone (hybrid alarm), and high-frequency tone. The median age of study subjects was 62.0 years and 87.1% were female. All (n = 31) subjects awakened and performed the escape procedure to all four alarms; The median time-to-awaken was 1.0 s for all four alarms and the median time-to-escape was 4.0 s for the female voice alarm and 5.0 s for the other three alarms. Pairwise comparisons among all four alarms did not show any significant differences in the probability functions for time-to-awaken or time-to-escape. Older adult participants rapidly awakened and performed the escape procedure to all the alarm types tested. Study results suggest that smoke alarms that were developed for the unique developmental requirements of sleeping children are also effective among sleeping older adults. The findings of this study contribute to identification of smoke alarm signals that are effective for individuals of all ages.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Noise Effects and Management · Injury Epidemiology and Prevention · Traffic and Road Safety

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (39)

Show source-provided references
1. Geiman JA, Gottuk DT (2006) Reducing fire deaths in older adults: optimizing the smoke alarm signal research project; summary technical report. The fire protection research foundation, Quincy, MA. https://www.sustainable-design.ie/fire/NFPA_Summary-Report_2006_Fire-Older-Auditory-Arousal.pdf. Accessed December 14, 2020.
2. Bruck D, Ball M (2007) Optimizing emergency awakening to audible smoke alarms: an update. Hum Factors 49(4):585–60110.1518/001872007X215674 ↗
3. Bruck D, Horasan M (1996) Non-arousal and non-action of normal sleepers in response to a smoke detector alarm. Fire Saf J 25:125–13910.1016/0379-7112(95)00041-0 ↗
4. Busby KA, Mercier L, Pivik RT (1994) Ontogenetic variations in auditory arousal threshold during sleep. Psychophysiology 31(2):182–18810.1111/j.1469-8986.1994.tb01038.x ↗
5. Nober EH, Pierce H, Well A (1981) Waking effectiveness of household smoke and fire detection devices. Fire J 75:86–130
6. Smith GA, Chounthirath T, Splaingard M (2020) Comparison of the effectiveness of female voice, male voice, and hybrid voice-tone smoke alarms for sleeping children. Pediatr Res 88(5):769–77510.1038/s41390-020-0838-1 ↗
7. Smith GA, Chounthirath T, Splaingard M (2019) Effectiveness of a voice smoke alarm using the child’s name for sleeping children: a randomized trial. J Pediatr 205:250–25610.1016/j.jpeds.2018.09.027 ↗
8. Smith GA, Chounthirath T, Splaingard M (2020) Do sleeping children respond better to a smoke alarm that uses their mother’s voice? Acad Pediatr 20(3):319–32610.1016/j.acap.2019.06.016 ↗
9. Smith GA, Splaingard M, Hayes JR, Xiang H (2006) Comparison of a personalized parent voice smoke alarm with a conventional residential tone smoke alarm for awakening children. Pediatrics 118(4):1623–163210.1542/peds.2006-0125 ↗
10. Underwriters laboratories, smoke alarm STP research group (2003) Report from the UL smoke alarm STP research group on childhood awakening in response to smoke alarms. Underwriters Laboratories, Northbrook, IL
11. Bruck D (1999) Non-awakening in children in response to a smoke detector alarm. Fire Saf J 32(4):369–37610.1016/S0379-7112(98)00035-6 ↗
12. Bruck D, Bliss RA (2000) Sleeping children and smoke alarms. In: Yamada T (ed) Proceedings of the fourth Asia-Oceania symposium on fire science and technology. Tokyo, Japan: Asia-Oceania symposium on fire science and technology 602–613
13. Bruck D, Reid S, Kouzma J, Ball M (2004) The effectiveness of different alarms in waking sleeping children. Proceedings from the 3rd international symposium on human behaviour in fire; Belfast, Ireland 279–289
14. Smith GA, Kistamgari S, Splaingard M (2020) Optimizing smoke alarm signals: testing the effectiveness of children’s smoke alarms for sleeping adults. Inj Epidemiol 7:5110.1186/s40621-020-00279-6 ↗
15. Ahrens M (2018) Home fire victims by age and gender. National fire protection association, Quincy, MA. https://www.nfpa.org//-/media/Files/News-and-Research/Fire-statistics-and-reports/Building-and-life-safety/oshomevictims.pdf. Accessed December 14, 2020
16. United states fire administration (2020) Fire safety outreach materials for older adults. United States fire administration, federal emergency management agency, department of homeland security, Washington DC; https://www.usfa.fema.gov/prevention/outreach/older_adults.html Accessed December 14, 2020
17. United states fire administration (2006) Fire and the older adult. FA-300. United States fire administration, national fire data center. Federal emergency management agency, department of homeland security, Washington DC. https://www.usfa.fema.gov/downloads/pdf/statistics/fa-300.pdf. Accessed December 14, 2020
18. Bruck D, Thomas I (2008) Comparison of the effectiveness of different fire notification signals in sleeping older adults. Fire Technol 44(1):15–3810.1007/s10694-007-0017-5 ↗
19. Berry RB, Brooks R, Gamaldo CE et al (2016) The AASM manual for the scoring of sleep and associated events: rules, terminology and technical specifications. American Academy of Sleep Medicine, Darien, IL
20. Rechtschaffen A, Kales A (1968) A manual of standardized terminology, techniques and scoring systems for sleep stages of human subjects. US Government Printing Office, Washington, DC
21. Bonnet MH, Johnson LC, Webb WB (1978) The reliability of arousal threshold during sleep. Psychophysiology 15(5):412–41610.1111/j.1469-8986.1978.tb01407.x ↗
22. Bruck D (2001) The who, what, where and why of waking to fire alarms: a review. Fire Saf J 36(7):623–63910.1016/S0379-7112(01)00025-X ↗
23. Zepelin H, McDonald CS, Zammit GK (1984) Effects of age on auditory awakening thresholds. J Gerontol 39(3):294–30010.1093/geronj/39.3.294 ↗
24. National fire protection association (2019) NFPA 72: national fire alarm and signaling code. National Fire Protection Association, Quincy, MA
25. Proulx G, Laroche C (2003) Recollection, identification and perceived urgency of the temporal-three evacuation signal. J Fire Prot Eng 13(1):67–8210.1177/1042391503013001004 ↗
26. Bruck D (1998) Technical report FCRC-TR 98–04: arousal from sleep with a smoke detector alarm in children and adults. http://www.abcb.gov.au/-/media/Files/Resources/Research/FCRC-TR-98-04-Arousal-from-sleep-smoke-detector-in-children-and-adults.pdf. Accessed May 22, 2020
27. Hellier E, Edworthy J, Weedon B, Walters K, Adams A (2002) The perceived urgency of speech warnings: semantics versus acoustics. Hum Factors 44(1):1–1710.1518/0018720024494810 ↗
28. Smith JJ, Wogalter MS (2007) Perceived effectiveness of warning messages for use as vocal warnings in residential fire alarms. Proc Hum Factors Ergo Soc Annu Meet 51(20):1398–140210.1177/154193120705102005 ↗
29. Ball M, Bruck D (2004) The salience of fire alarm signals for sleeping individuals: a novel approach to signal design. In proceedings of the 3rd international symposium on human behaviour in fire. Belfast, Ireland. 303–314
30. Laboratories Underwriter (2020) UL 217 Standard for smoke alarms, Edition 9. Underwriters Laboratories, Northbrook, IL
31. Dement WC (2016) Normal human sleep. In: Kryger MH, Roth T, Dement WC (eds) Principles and Practice of Sleep Medicine, 6th edn. Elsevier
32. Glen S (2021) Hazard ratio: definition, examples and log of the hazard. In StatisticsHowTo.com. Elementary statistics for the rest of us! www.statisticshowto.com/hazard-ratio/. Accessed May 21, 2021
33. Bruck D, Thomas IR (2012) Community-based research on the effectiveness of the home smoke alarm in waking up children. Fire Mater 36(5–6):339–34810.1002/fam.1081 ↗
34. Baker SP (1981) Childhood injuries: the community approach to prevention. J Public Health Policy 2(3):235–24610.2307/3342369 ↗
35. Thomas I, Bruck D (2010) Awakening of sleeping people: a decade of research. Fire Technol 46:743–76110.1007/s10694-008-0065-5 ↗
36. Cruickshanks KJ, Wiley TL, Tweed TS et al (1998) Prevalence of hearing loss in older adults in Beaver Dam, Wisconsin. The epidemiology of hearing loss study. Am J Epidemiol 148(9):879–88610.1093/oxfordjournals.aje.a009713 ↗
37. Dinaburg JB (2020) Audible alarm signal waking effectiveness: literature review. Report number FPRF-2020–04. Quincy, MA: fire protection research foundation, national fire protection association
38. Olenick SM, Boehmer H, Klassen MS (2019) Door messaging strategies: implications for detection and notification. Report number FPRF-2019–12. Quincy, MA: fire protection research foundation, national fire protection association10.1007/s10694-020-01049-y ↗
39. Quirt JD (1987) Sound transmission through building components. Noise control in buildings: proceedings of building science insight. Institute for research in construction, national research council of Canada. Canada. 23–38. https://nrc-publications.canada.ca/eng/view/object/?id=86fc10e0-885c-41c5-8608-aef1933bd77d. Accessed December 14, 2020