journal article·2022-01

Experimental Study of Sub-critical Velocity in Longitudinally Ventilated Tunnels

Dongli Gao, Xingchao Chen, Xinyu Yang, Y. O. Tong, Peng Lin

Fire Technology· Volume 58· Issue 1
Publisher page

Abstract

The critical velocity is the minimum velocity blowing towards the fire seat in tunnels to reduce the length of back-layering to zero, and it has been extensively adopted in the design of longitudinal smoke control in tunnels. A new concept, i.e., sub-critical velocity, is proposed in lieu of critical velocity for longitudinally ventilated tunnels. The sub-critical velocity allows the presence of back-layering upstream of the fire, provided that the back-layering is kept above the heads of motorists, thus posing no detrimental impact on them during evacuation. Experiments with propane fires with heat release rates of 3.7–25.5 kW were conducted in a 1/20 reduced-scale model tunnel. Both the lengths and the heights of back-layering at varying HRRs and longitudinal velocities were studied. Subsequently, the relationship of critical velocity and sub-critical velocity were developed. The results showed that sub-critical velocity is around 45–60% of the critical velocity. The adoption of sub-critical velocity in the design of longitudinally ventilated tunnels not only significantly reduces the cost of fans to drive the airflow, but also minimizes the impact of ventilation on heat release rates.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fire dynamics and safety research · Evacuation and Crowd Dynamics · Fire effects on ecosystems

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (26)

Show source-provided references
1. Thomas PH (1958) The movement of buoyant fluid against a stream and the venting of underground fires. Fire Saf Sci 351:1
2. Thomas PH (1968) The movement of smoke in horizontal passages against an air flow. Fire Saf Sci 723:1
3. Oka Y, Atkinson GT (1995) Control of smoke flow in tunnel fires. Fire Saf J 25:305–32210.1016/0379-7112(96)00007-0 ↗
4. Li YZ, Lei B, Ingason H (2010) Study of critical velocity and backlayering length in longitudinally ventilated tunnel fires. Fire Saf J 45:361–37010.1016/j.firesaf.2010.07.003 ↗
5. Li YZ, Ingason H (2017) Effect of cross section on critical velocity in longitudinally ventilated tunnel fires. Fire Saf J 91:303–31110.1016/j.firesaf.2017.03.069 ↗
6. Wu Y, Bakar MA (2000) Control of smoke flow in tunnel fires using longitudinal ventilation systems—a study of the critical velocity. Fire Saf J 35:363–39010.1016/S0379-7112(00)00031-X ↗
7. Lee SR, Ryou HS (2016) An experimental study of the effect of the aspect ratio on the critical velocity in longitudinal ventilation tunnel fires. J Fire Sci 23:119–13810.1177/0734904105044630 ↗
8. Weng MC, Lu XL, Liu F, Du CX (2016) Study on the critical velocity in a sloping tunnel fire under longitudinal ventilation. Appl Therm Eng 94:422–43410.1016/j.applthermaleng.2015.10.059 ↗
9. Atkinson GT, Wu Y (1996) Smoke control in sloping tunnels. Fire Saf J 27:335–34110.1016/S0379-7112(96)00061-6 ↗
10. Kang K (2010) Characteristic length scale of critical ventilation velocity in tunnel smoke control. Tunn Undergr Space Technol 25:205–21110.1016/j.tust.2009.11.004 ↗
11. Zhou Y, Bi H, Wang H, Lei B (2019) Critical velocity in the transverse passages of a railway tunnel rescue station with semi-transverse ventilation. Tunn Undergr Space Technol 92:10306410.1016/j.tust.2019.103064 ↗
12. Lee Y-P, Tsai K-C (2012) Effect of vehicular blockage on critical ventilation velocity and tunnel fire behavior in longitudinally ventilated tunnels. Fire Saf J 53:35–4210.1016/j.firesaf.2012.06.013 ↗
13. Tanaka F, Takezawa K, Hashimoto Y, Moinuddin KA (2018) Critical velocity and backlayering distance in tunnel fires with longitudinal ventilation taking thermal properties of wall materials into consideration. Tunn Undergr Space Technol 75:36–4210.1016/j.tust.2017.12.020 ↗
14. Hu P, Zhang Z, Zhang X, Tang F (2020) An experimental study on the transition velocity and smoke back-layering length induced by carriage fire in a ventilated tunnel. Tunn Undergr Space Technol 106:10360910.1016/j.tust.2020.103609 ↗
15. Rojas Alva WU, Jomaas G, Dederichs AS (2017) The influence of vehicular obstacles on longitudinal ventilation control in tunnel fires. Fire Saf J 87:25–3610.1016/j.firesaf.2016.11.001 ↗
16. Peng M, Zhang S, Yang H, He K, Cong W, Cheng X, Yuen R, Zhang H (2020) Experimental study on confinement velocity in tunnel fires with longitudinal ventilation. J Wind Eng Ind Aerodyn 201:10415710.1016/j.jweia.2020.104157 ↗
17. Akizuki Y, Tanaka T (2013) Prediction model for target luminance in fire smoke by taking into consideration the adhesion of smoke particles. Proc Eng 62:483–49210.1016/j.proeng.2013.08.091 ↗
18. CIBSE (2010) Fire safety engineering, 3rd edn. The Chartered Institution of Building Services Engineers, London
19. Modak AT (1977) Thermal radiation from pool fires. Combust Flame 29:177–19210.1016/0010-2180(77)90106-7 ↗
20. Vauquelin O, Telle D (2005) Definition and experimental evaluation of the smoke “confinement velocity” in tunnel fires. Fire Saf J 40:320–33010.1016/j.firesaf.2005.02.004 ↗
21. Quintiere JG (1989) Scaling applications in fire research. Fire Saf J 15:3–2910.1016/0379-7112(89)90045-3 ↗
22. Lin P, Wang ZK, Wang KH, Gao DI, Shi JK, You SH, Chen ZN, Wang GY, Mei XJ (2019) An experimental study on self-extinction of methanol fire in tilted tunnel. Tunn Undergr Space Technol 91:10299610.1016/j.tust.2019.102996 ↗
23. You SH, Wang KH, Shi JK, Chen ZN, Gao DL, Chen JM, Lin P (2020) Self-extinction of methanol fire in tunnel with different configuration of blocks. Tunn Undergr Space Technol 98:10334310.1016/j.tust.2020.103343 ↗
24. Chow WK, Han SS (2011) Heat release rate calculation in oxygen consumption calorimetry. Appl Therm Eng 31:304–31010.1016/j.applthermaleng.2010.09.010 ↗
25. Yao YZ, Cheng XD, Zhang SG, Zhu K, Shi L (2016) Smoke back-layering flow length in longitudinal ventilated tunnel fires with vertical shaft in the upstream. Appl Therm Eng 107:738–74610.1016/j.applthermaleng.2016.07.027 ↗
26. Yi L, Xu Q, Xu Z, Wu D (2014) An experimental study on critical velocity in sloping tunnel with longitudinal ventilation under fire. Tunn Undergr Space Technol 43:198–20310.1016/j.tust.2014.05.017 ↗