Experimental Investigation of Water-Based Fire Suppression Systems on External Façade Fires

Christoph Meraner, Ellen S. Skilbred, Kemal S. Arsava

Fire Technology· Volume 60· Issue 5

Abstract

Abstract The use of external fire suppression systems can reduce the risk of fire spreading between buildings. This study investigated the effectiveness and efficiency of different externally placed water-based fire suppression systems on façade fire safety. A series of large-scale experiments comprising an SP Fire 105 setup equipped with sprinklers and high-pressure water mist nozzles have been performed. A combustible façade, consisting of 2.5 cm thick oriented strand board (OSB) plates, was installed to provide challenging conditions and allow a visual assessment of the post-fire damage. The temperature profile on the façade surface was measured with 34 thermocouples, while five heat flux gauges and two fast-response plate thermocouples were used to measure the heat flux on the façade surface and emitted to the ambient. The sprinklers and the high-pressure water mist system effectively suppressed the upwards flame migration and reduced the heat flux toward adjacent buildings. It was observed that the sprinklers acted as a water curtain and kept the façade wet during the fire, promoting minor damage (the burnt area is less than 1% of the total area). The temperature and heat flux measurements demonstrated that the sprinkler system was the most effective suppression system. However, the high-pressure water mist systems achieved similar effectiveness but a much higher efficiency concerning water consumption. The sprinkler nozzles used four times as much water as the high-pressure water mist nozzles.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Fire dynamics and safety research · Wind and Air Flow Studies · Evacuation and Crowd Dynamics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (23)

Show source-provided references
1. Kim AK, Taber BC, Lougheed GD (1998) Sprinkler protection of exterior glazing. Fire Technol 34(2):116–138. https://doi.org/10.1023/A:101532541866610.1023/A:1015325418666 ↗
2. Gui J et al (2019) Full-scale experimental study on the suppression effect of water sprinkler system on energy saving building fire. IOP Conf Ser Earth Environ Sci 354(1):012096. https://doi.org/10.1088/1755-1315/354/1/01209610.1088/1755-1315/354/1/012096 ↗
3. Węgrzyński W, Antosiewicz P, Burdzy T, Tofiło P, Papis BK (2020) Experimental investigation into fire behaviour of glazed façades with pendant type sprinklers. Fire Saf J 115:103159. https://doi.org/10.1016/j.firesaf.2020.10315910.1016/j.firesaf.2020.103159 ↗
4. NFPA "NFPA 750 Standard on Water Mist Fire Protection Systems," NFPA (2019)
5. Yang W, Parker T, Ladouceur HD, Kee RJ (2004) The interaction of thermal radiation and water mist in fire suppression. Fire Saf J 39(1):41–66. https://doi.org/10.1016/j.firesaf.2003.07.00110.1016/j.firesaf.2003.07.001 ↗
6. Parent G, Morlon R, Acem Z, Fromy P, Blanchard E, Boulet P (2016) Radiative shielding effect due to different water sprays used in a real scale application. Int J Therm Sci 105:174–181. https://doi.org/10.1016/j.ijthermalsci.2016.02.00810.1016/j.ijthermalsci.2016.02.008 ↗
7. Collin A, Lechene S, Boulet P, Parent G (2010) Water mist and radiation interactions: application to a water curtain used as a radiative shield. Numer Heat Transf Part Appl 57(8):537–553. https://doi.org/10.1080/1040778100374472210.1080/10407781003744722 ↗
8. Fisher BT, Awtry AR, Sheinson RS, Fleming JW (2007) Flow behavior impact on the suppression effectiveness of sub-10-μm water drops in propane/air co-flow non-premixed flames. Proc Combust Inst 31(2):2731–2739. https://doi.org/10.1016/j.proci.2006.07.02310.1016/j.proci.2006.07.023 ↗
9. SP FIRE 105. External wall assemblies and façade claddings. Reaction to fire. Swedish National Testing and Research Institute, Fire Technology, Borås, Sweden, Sep 09, 1994
10. ISO 6182-1 Fire protection—automatic sprinkler systems—part 1: requirements and test methods for sprinklers (2021)
11. Ingason H, Wickström U (2007) Measuring incident radiant heat flux using the plate thermometer. Fire Saf J 42(2):161–166. https://doi.org/10.1016/j.firesaf.2006.08.00810.1016/j.firesaf.2006.08.008 ↗
12. Moneib HA (1980) Experimental study of the fluctuating temperature in inert and reacting turbulent jets, Imperial Collage of Science and Technology
13. Bradley D, Mathews KJ (1968) Measurement of high gas temperatures with fine wire thermocouples. J Mech Eng Sci 10(4):299–305. https://doi.org/10.1243/JMES_JOUR_1968_010_048_0210.1243/JMES_JOUR_1968_010_048_02 ↗
14. Kaskan WE (1957) The dependence of flame temperature on mass burning velocity. In: 6th symposium (international) on combustion. The Combustion Institute, Pittsburgh, pp 34–143
15. Baum HR, McCaffrey BJ (1989) Fire induced flow field-theory and experiment. In: Proceedings of the second international symposium on fire safety science, New York, USA, pp 129–14810.3801/IAFSS.FSS.2-129 ↗
16. Kuo CH, Kulkarni AK (1991) Analysis of heat flux measurement by circular foil gages in a mixed convection/radiation environment. J Heat Transf 113(4):1037–104010.1115/1.2911202 ↗
17. Burrell G, Hare J (2006) Review of HSE building ignition criteria. Health & Safety Laboratory, Fire and Explosion Science Group, Derbyshire, UK, HSL/2006/33
18. LaChance J, Tchouvelev A, Engebo A (2011) Development of uniform harm criteria for use in quantitative risk analysis of the hydrogen infrastructure. Int J Hydrog Energy 36(3):2381–238810.1016/j.ijhydene.2010.03.139 ↗
19. Abu-Zidan Y, Rathnayaka S, Mendis P, Nguyen K (2022) Effect of wind speed and direction on facade fire spread in an isolated rectangular building. Fire Saf J 129:10357010.1016/j.firesaf.2022.103570 ↗
20. Fang X, Ren F, Zhang X, Sun X, Yang Y, Hu L (2020) Facade flame height ejected from opening of a compartment under the coupling effect of side walls and ambient wind. Fire Saf J 112:10296610.1016/j.firesaf.2020.102966 ↗
21. Hu L, Hu K, Ren F, Sun X (2017) Facade flame height ejected from an opening of fire compartment under external wind. Fire Saf J 92:151–15810.1016/j.firesaf.2017.06.008 ↗
22. Liu Y, Fang Z, Tang Z, Beji T, Merci B (2021) The combined effect of a water mist system and longitudinal ventilation on the fire and smoke dynamics in a tunnel. Fire Saf J 122:10335110.1016/j.firesaf.2021.103351 ↗
23. Crosfield R, Cavallo A, Colella F, Carvel R, Torero J, Rein G (2009) Approximate travelling distances of water mist droplets in tunnels. Presented at the International Water Mist Conference, London, UK, Sep 2009