journal article·2020-09

Fast-Response Sprinkler Technology: Hsiang-Cheng Kung, Gunnar Heskestad, Robert Bill, Roger Allard: The 2019 Phillip J. DiNenno Prize

P. Croce, C. Beyler, C. Dubay, P. Johnson, M. McNamee

Fire Technology· Volume 56· Issue 5
Publisher page

Abstract

The National Fire Protection Association has recognized fast-response sprinkler technology, developed and promulgated by Factory Mutual Research Corporation (FMRC, now FM Global), with its 2019 Phillip J. DiNenno Prize. This technology was the result of three innovative efforts that produced Response-Time Index (RTI), quick-response (QR) residential sprinklers, and the Early Suppression, Fast Response (ESFR) sprinkler. Cheng Yao (deceased), who led sprinkler research at FMRC (now FM Global), was the prime mover for this work. Dr. Gunnar Heskestad was responsible for conceptual work and much of the research and development work for RTI, as well as a good deal of the underlying research for ESFR. Dr. Hsiang-Cheng Kung did the conceptual and RD he also conducted a significant amount of research work for ESFR development. Dr. Robert G. Bill provided additional experimental research work for RTI, including the adaptation of the RTI wind tunnel for testing recessed, flush and concealed sprinklers, as well as support work for Heskestad’s proposed resolution to the conduction complication identified by Jerome Pepi (deceased). He also worked extensively and closely with Roger L. Allard who was instrumental in gaining global acceptance and promulgation of these technologies worldwide. As the DiNenno Prize is not awarded posthumously, only those individuals identified in bold text were awarded the prize.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fire dynamics and safety research · Evacuation and Crowd Dynamics · Urban Heat Island Mitigation

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (70)

Show source-provided references
1. FPC (Fire Protection Contractor) Magazine (1998, March) History timeline, 20th-year History Edition
2. Thomas PH (1955) The distribution of temperature and velocity due to fires beneath ceiling. Fire Research Notes 141
3. Heskestad G, Smith HF (1976, December) Investigation of a new sprinkler sensitivity approval test: the plunge test. FMRC Serial No. 22485, Norwood, MA
4. Heskestad G, Smith HF (1980, December) Plunge test for determination of sprinkler sensitivity. Technical Report, FMRC J.I. No. 3A1E2.RR, Norwood, MA
5. Approval Standard: Residential Automatic Sprinklers (1983) Class 2030. Factory Mutual Research Corporation, Norwood, MA, USA
6. Bill Jr. RG (1987, March) U.S. TAG proposal for dynamic heating test. ISO No. 139, presented at ISO/TC21/SC5/WG1, Hamburg, Germany
7. Pepi JS (1986) Design characteristics of quick response sprinklers. Grinnell Fire Protection Systems Company, Providence
8. Heskestad G, Bill Jr. RG (1987, September) Conduction heat loss effects on thermal response of automatic sprinklers. FMRC Serial No. 0N0J5.RU/0NlJ6.RU, Norwood, MA
9. Heskestad G, Bill Jr. RG (1988) Quantification of thermal responsiveness of automatic sprinklers including conduction effects. Fire Saf J 14:11310.1016/0379-7112(88)90049-5 ↗
10. Bill Jr. RG (1989) A comparison between plunge and ramp test methods for determining the thermal sensitivity of automatic sprinklers. Society of Fire Protection Engineers, Washington
11. Heskestad G, Bill Jr. RG (1989) Modeling of thermal responsiveness of automatic sprinklers. In: Fire safety science: proceedings of the second international symposium. Hemisphere Publishing Corporation, New York, pp 603–61210.3801/IAFSS.FSS.2-603 ↗
12. Bill Jr. RG (1991, October 7–12) Thermal sensitivity limits of sprinklers. ISO No. 202, presented at ISO/TC21/SC5/WG1 Meeting on Automatic Sprinklers, Munich, Germany
13. Bill Jr. RG (1993) Thermal sensitivity limits of residential sprinklers. Fire Saf J 21:131–152.10.1016/0379-7112(93)90039-S ↗
14. Bill Jr. RG, Allard R, Braga A, Ferron R (1995) Standardized extended coverage sprinklers in light hazard occupancies. J Fire Prot Eng 7(4):133–15110.1177/104239159500700403 ↗
15. Bill Jr. RG, Heskestad G (1995, February) Plunge test procedures for recessed, flush and concealed sprinklers. FMRC J.I. 0Y0J1.RA, Norwood, MA
16. Bill Jr. RG, Heskestad G (1997) Thermal sensitivity evaluation of recessed, flush and concealed sprinklers. In: Fire safety science: proceedings of the fifth international symposium. International Association for Fire Safety Science, pp 865–876
17. Draft International Standard (ISO, DIS 6182-1.2) (1991) Fire protection automatic sprinkler systems, part 1, requirements and methods of tests for sprinklers, ISO 6182-1. International Organization for Standardization, Geneva
18. Pickard RW, Hird D, Nash P (1957) The thermal testing of heat-sensitive fire detectors. Fire Research Notes 247
19. Alpert RL (1972) Calculation of response time of ceiling-mounted fire detectors. Fire Technol 8(3):181–19510.1007/BF02590543 ↗
20. Heskestad G, Delichatsios MA (1978) The initial convective flow in fire. In: 17th international symposium on combustion. Combustion Institute, Pittsburgh10.1016/S0082-0784(79)80106-X ↗
21. Heskestad G (1984) Engineering relations for fire plumes. Fire Saf J 7(1):25–3210.1016/0379-7112(84)90005-5 ↗
22. Beyler CL (1986) Fire plumes and ceiling jets. Fire Saf J 11:53–75 (a review of plume and ceiling jet correlations)10.1016/0379-7112(86)90052-4 ↗
23. Beyler CL (1984) A design method for flaming fire detection. Fire Technol 20(4):510.1007/BF02389990 ↗
24. Stroup D, Evans D (1988) Use of computer fire models for analyzing thermal detector spacing. Fire Saf J 14(1–2):3310.1016/0379-7112(88)90043-4 ↗
25. McGrattan KB, Hamins A, Stroup D (1998, September) Sprinkler, smoke & heat vent, draft curtain interaction: large scale experiments and model development. NISTIR 6196-110.6028/NIST.IR.6196-1 ↗
26. FM Global Open Source CFD Fire Modeling Workshop (2017, May 9–10) FM Global, Norwood, MA
27. Meredith KV, Zhou X, Ren N, Chatterjee P, Wang Y (2017, May 10) Suppression modeling of roll-paper storage: validation and prediction. FM Global Open Source CFD Fire Modeling Workshop, FM Global, Norwood, MA
28. Kung HC (1975, November) Residential sprinkler-protection study. FMRC Serial No. 22442, RC75-T-41, Prepared for the National Bureau of Standards
29. Kung HC (1977) Cooling of room fires by sprinkler spray. Trans ASME J Heat Transf 99(3):353–35910.1115/1.3450702 ↗
30. Dundas PH (1972) The scaling of sprinkler discharge: prediction of drop size. Progress Report No. 10 in Optimization of Sprinkler Fire Protection, Technical Report RC73-T-40, Factory Mutual Research Corporation, Norwood, MA
31. Kung HC, Haines DM, Greene RE (1978, February) Development of low-cost residential sprinkler protection. FMRC Serial No. 22574, RC78-T-3, Prepared for the National Fire Prevention and Control Administration
32. Kung HC, Spaulding RD, Hill Jr. EE (1980) Sprinkler performance in residential fire tests. Technical Report RC80-T-16, Serial No. 22574, Factory Mutual Research Corporation, Norwood, MA, USA
33. Kung HC, Spaulding RD, Hill Jr. EE, Symonds AP (1982) Field evaluation of residential prototype sprinkler in Los Angeles fire test program. Technical Report J.I. 0E0R3.RA(1), Factory Mutual Research Corporation, Norwood, MA, USA
34. Cote AE (1983) Field test and evaluation of residential sprinkler systems: part I. Fire Technol 19(4):22110.1007/BF02380807 ↗
35. Cote AE (1984) Field test and evaluation of residential sprinkler systems: part II. Fire Technol 20(1):4810.1007/BF02390047 ↗
36. NFPA 13D: Sprinkler Systems- One- and Two-Family Dwellings (1980) National Fire Protection Association, Quincy, MA, USA
37. ANSI/UL 1626 Standard for Residential Sprinklers for Fire-Protection Service (November 2018)
38. FM Global Approval Standard for Residential Automatic Sprinklers for Fire Protection (2009, August), Norwood, MA
39. Walton WD, Budnick EK (1988, January) Quick response sprinklers in office configurations: fire test results. NIST, NBSIR-88-3695, Gaithersburg, MD10.6028/NBS.IR.88-3695 ↗
40. Yao C (1988) Development of the ESFR sprinkler system. Fire Saf J 14:65–7310.1016/0379-7112(88)90045-8 ↗
41. Yao C (1997) Overview of sprinkler technology research. In: Fire safety science: proceedings of the fifth international symposium. International Association for Fire Safety Science, pp 93–11010.3801/IAFSS.FSS.5-93 ↗
42. You HZ, Kung HC (1985) Strong buoyant plumes of growing rack storage fires. In: Twentieth symposium (international) on combustion. The Combustion Institute, pp 1547–1554
43. Kung HC, You HZ, Spaulding RD (1988) Ceiling flows of growing rack storage fires. In: Proceedings of the twenty-first symposium (international) on Combustion. The Combustion Institute, 1986, pp 121–12810.1016/S0082-0784(88)80238-8 ↗
44. Chan TS, Kung HC, Yu HZ, Brown WR (1994) Experimental study of actual delivered density for rack-storage fires. In: Fire safety science: proceedings of the fourth international symposium. International Association for Fire Safety Science, pp 913–92410.3801/IAFSS.FSS.4-913 ↗
45. Chan TS, Kung HC (2002) Comparison of actual delivered density and fire suppression effectiveness of standard and conventional sprinklers in rack-storage fires. In: Fire safety science: proceedings of the seventh international symposium. International Association for Fire Safety Science, pp 445–456
46. Yu HZ, Lee JL, Kung HC (1994) Suppression of rack storage fire by water. In: Fire safety science: proceedings of the fourth international symposium. International Association for Fire Safety Science, pp 901–912
47. Approval Standard for Quick Response Storage Sprinklers for Fire Protection, Class 2008 (2018, February) Factory Mutual Research Corporation, Norwood, MA, USA
48. Kung HC, Vincent BG, Chan TK, Yu HZ, Stavrianidis P (1998) Early suppression fast response (ESFR) sprinkler protection for 12 m high warehouses. In: Fire safety science: proceedings of the ffth international symposium. International Association for fire Safety Science, pp 877–888
49. Chan T-S (1994) Measurements of spray characteristics of selected ESFR sprinklers. J Fire Prot Eng 6(2):1110.1177/104239159400600202 ↗
50. Dombrowski N, Wolfsohn DL (1972) The atomization of water by swirl spray pressure nozzles. Trans Inst Chem Eng 50:259
51. Kung HC, Yu HZ, Brown WR, Vincent BG (1988) Four-tier array rack storage fire tests with fast-response prototype sprinklers. In: Second international symposium on fire safety science. International Association for Fire Safety Science, pp 633–642
52. “Approval Standard — Early Suppression Fast Response (ESFR),” Automatic Sprinklers. Class No. 2008 (1996) Factory Mutual Research Corporation
53. International Standard ISO 6182-7 Fire Protection- Automatic Sprinkler systems- Part 7: Requirements and test methods for early suppression fast response (ESFR) sprinklers (2004) First edition 2004-04-01.
54. NFPA 231C: Rack Storage of Materials (1991) National Fire Protection Association, Quincy, MA, USA.
55. Code for Design of Automatic Fire Sprinkler System (1998) Ministry of Public Security, People’s Republic of China
56. Kung HC (2002) Effect of ceiling obstructions upon the performance of ESFR pendent in 12 m high buildings. Progress in Safety Science and Technology, Science Press, Beijing, China, vol 3, pp 1101–1105
57. Ditch B, de Ris J, Yu HZ (2008) Evaluation of the skip-resistant sprinkler concept. Technical Report, FM Global, Norwood, MA10.1177/1042391509346231 ↗
58. De Ris JL, Yu HZ, Ditch BD (2010, April 2) Anti-skipping sprinkler. US Patent 7699116 B2, FM Global, Norwood, MA
59. FM Global Property Loss Prevention Data Sheets 2-0 (2014, January). FM Global, Norwood, MA, USA.
60. NFPA 13 Standard for the Installation of Sprinkler Systems (2013) National Fire Protection Association, Quincy, MA, USA
61. Palenske GA, Fletcher WN (2015, September) Obstructions and ESFR sprinklers: phase 2. Aon, San Diego, CA, USA
62. Palenske GA, Fletcher WN (2016) Obstructions and ESFR sprinklers: phase 3. Jensen Hughes, San Diego
63. Budnick EK (1984) Estimating effectiveness of state-of-the-art detectors and automatic sprinklers on life safety in residential occupancies. Fire Technol 20(3):40910.1007/BF02384161 ↗
64. Automatic Sprinklers: A 10 Year Study (1997) A detailed history of the effects of the automatic sprinkler code in Scottsdale, Arizona; produced in cooperation with the Home Fire Sprinkler Coalition. Copyright 1997: Assistant Chief Jim Ford, Rural/Metro Fire Department, Scottsdale, Arizona
65. Benefits of Residential Fire Sprinklers: Prince George’s County, A 15-Year History with its Single-Family Residential Dwelling Fire Sprinkler Ordinance (2009) Prepared by Steve Weatherby, for Home Fire Coalition
66. Communities with Home Fire Sprinklers: The Experience in Bucks County, Pennsylvania (2011) Produced in collaboration with the Bucks County Fire Marshals Association for the Home Fire Sprinkler Coalition (HFSC). Fire Planning Associates, Inc., Washington
67. Hall JR (2013, June) U.S. experience with sprinklers, NFPA Fire Analysis and Research Division Report, No. USS14. NFPA, Quincy, MA
68. Wieczorek CJ, Ditch B, Bill RG Jr. (2010) Environmental impact of automatic fire sprinklers. Technical Report, FM Global, Norwood, MA10.1007/s10694-010-0192-7 ↗
69. Amon F, Gehandler J, McNamee R, McNamee M, Vilic A (2019) Measuring the impact of fire on the environment (Fire Impact Tool, version 1): project report and user manual. RISE Report 2019, vol 60. https://doi.org/10.23699/tmpv-pj7110.23699/tmpv-pj71 ↗
70. Peter T (1983) The thermal response of sprinkler heads. BRE Note N 47/83, British Research Establishment, FRS, UK