Behaviour of Reinforced Concrete Walls Under Fire: A Review
Source abstract
Abstract
Fire has been a scourge of society for a very long time due to its impact on the human and economic aspects. Fire resistance is a characteristic of concrete buildings, and residential buildings made of concrete are often subject to fire. Fire causes serious damage to the concrete members, which may require substantial demolition. High temperatures decrease the stability and durability of concrete structures; therefore, understanding the effect of fire on concrete walls can help in reduce the environmental fire impact and lower rehabilitation costs. Several studies investigated the impact of fire on the response of concrete walls. This paper reviews previous studies until 2020. The paper aims to discuss the effect of fire load on the behaviour of concrete walls and panels. To this end, 102 previous studies were selected for the review. This paper commences by illustrating fire scenarios, heat and moisture transfer in concrete walls, and the influence of elevated temperature on concrete performance. This is followed by a discussion of structural analysis and failure limit states of concrete walls during fire. Next, the impact of applying different parameters on the structural and thermal behaviour of concrete walls exposed to fire is addressed, and significant parameters including axial load, lateral load, compressive strength, reinforcement ratio, concrete cover, moisture content, aggregate type, fire period, slenderness ratio, and load eccentricity are provided. Spalling, thermal response, and deformation of concrete walls during fire are also discussed. The paper concludes with recommendations for further studies.
Source: expertdata · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fire effects on concrete materials · Fire dynamics and safety research · Concrete Properties and Behavior
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (100+)
Show source-provided references
1. Gambarova PG, Felicetti R, Meda A, Riva P (2005) Fire design of concrete structures: what now? What next?
2. Hirschler MM (1992) Fire hazard and fire risk assessment, no. 1150. ASTM International10.1520/STP1150-EB ↗
3. Bangash MYH, Bangash T (2006) Fire and buildings with and without explosion/impact. Explos Build Des Anal Case Stud, pp 103–227
4. Zhou J, Wang L (2019) Repair of fire-damaged reinforced concrete members with axial load: a review. Sustainability 11(4):963. https://doi.org/10.3390/su1104096310.3390/su11040963 ↗
5. Chi J, Tang J, Go C, Huang Y (2014) Research on seismic resistance and mechanic behavior of reinforced lightweight aggregate concrete walls after high temperature. Fire Mater 38(8):789–805. https://doi.org/10.1002/fam.222110.1002/fam.2221 ↗
6. Mistri A, Pa RD, Sarkar P (2016) Condition assessment of fire affected reinforced concrete shear wall building: a case study. Adv Concr Constr 4(2):89–105. https://doi.org/10.12989/acc.2016.4.2.08910.12989/acc.2016.4.2.089 ↗
7. Lahoti M, Tan KH, Yang E-H (2019) A critical review of geopolymer properties for structural fire-resistance applications. Constr Build Mater 221:514–526. https://doi.org/10.1016/j.conbuildmat.2019.06.07610.1016/j.conbuildmat.2019.06.076 ↗
8. Lee J, Han S, Kim J (2014) Seismic performance evaluation of apartment buildings with central core. Int J High-Rise Build 3:9–19. https://doi.org/10.21022/IJHRB.2014.3.1.00910.21022/IJHRB.2014.3.1.009 ↗
9. Kumar P, Kodur VKR (2017) Modeling the behavior of load bearing concrete walls under fire exposure. Constr Build Mater 154:993–1003. https://doi.org/10.1016/j.conbuildmat.2017.08.01010.1016/j.conbuildmat.2017.08.010 ↗
10. Hayhoe WC, Youssef MA (2013) Structural behaviour of concrete walls during or after exposure to fire: a review. G E N 182:1
11. Ni S, Birely AC (2018) Post-fire seismic behavior of reinforced concrete structural walls. Eng Struct 168:163–178. https://doi.org/10.1016/j.engstruct.2018.04.01810.1016/j.engstruct.2018.04.018 ↗
12. Guerrieri M, Fragomeni S (2010) Spalling of normal strength concrete walls in fire. In: 6th international conference on structures in fire, pp 301–311
13. Thanaraj DP, Anand N, Arulraj P (2019) Experimental investigation of mechanical properties and physical characteristics of concrete under standard fire exposure. J Eng Des Technol 17(5):878–903. https://doi.org/10.1108/JEDT-09-2018-015910.1108/JEDT-09-2018-0159 ↗
14. Ni S, Birely AC (2018) A simplified model for the post-fire earthquake flexural response of reinforced concrete walls with boundary elements. Eng Struct 175:721–730. https://doi.org/10.1016/j.engstruct.2018.08.04410.1016/j.engstruct.2018.08.044 ↗
15. Chen J, Hamed E, Ian Gilbert R (2020) Structural performance of reinforced concrete walls under fire conditions. J Struct Eng. https://doi.org/10.1061/(ASCE)ST.1943-541X.000251910.1061/(ASCE)ST.1943-541X.0002519 ↗
16. Zheng YQ, Zhuang JP (2011) Analysis on fire resistance of reinforced concrete wall. Adv Mater Res 243–249:797–800. https://doi.org/10.4028/www.scientific.net/AMR.243-249.79710.4028/www.scientific.net/AMR.243-249.797 ↗
17. Kang J, Yoon H, Kim W, Kodur V, Shin Y, Kim H (2016) Effect of wall thickness on thermal behaviors of RC walls under fire conditions. Int J Concr Struct Mater 10(S3):19–31. https://doi.org/10.1007/s40069-016-0164-510.1007/s40069-016-0164-5 ↗
18. Ryu E, Kim H, Chun Y, Yeo I, Shin Y (2020) Effect of heated areas on thermal response and structural behavior of reinforced concrete walls exposed to fire. Eng Struct 207:110165. https://doi.org/10.1016/j.engstruct.2020.11016510.1016/j.engstruct.2020.110165 ↗
19. Xiao J, Xie Q, Li Z, Wang W (2017) Fire resistance and post-fire seismic behavior of high strength concrete shear walls. Fire Technol 53(1):65–86. https://doi.org/10.1007/s10694-016-0582-610.1007/s10694-016-0582-6 ↗
20. Pham DT, de Buhan P, Florence C, Heck J-V, Nguyen HH (2015) Yield design-based analysis of high rise concrete walls subjected to fire loading conditions. Eng Struct 87:153–161. https://doi.org/10.1016/j.engstruct.2015.01.02210.1016/j.engstruct.2015.01.022 ↗
21. BBC (2020) Abbco tower: fire engulfs skyscraper in UAE city of Sharjah - BBC News. https://www.bbc.com/news/world-middle-east-52553429. Accessed 5 Nov 2021
22. BBC (2020) Grenfell tower: what happened - BBC News. https://www.bbc.com/news/uk-40301289. Accessed 5 Nov 2021
23. Jansson R (2013) Fire spalling of concrete: theoretical and experimental studies. KTH Royal Institute of Technology
24. Khoury GA (2000) Effect of fire on concrete and concrete structures. Prog Struct Eng Mater 2(4):429–447. https://doi.org/10.1002/pse.5110.1002/pse.51 ↗
25. Li L et al (2020) A review on the recovery of fire-damaged concrete with post-fire-curing. Constr Build Mater 237:117564. https://doi.org/10.1016/j.conbuildmat.2019.11756410.1016/j.conbuildmat.2019.117564 ↗
26. Bisby L, Gales J, Maluk C (2013) A contemporary review of large-scale non-standard structural fire testing. Fire Sci Rev 2(1):110.1186/2193-0414-2-1 ↗
27. Gales J, Maluk C, Bisby L (2012) Large-scale structural fire testing-How did we get here, where are we, and where are we going?
28. Law M (1981) Designing fire safety for steel-recent work
29. Gravit M, Gumerova E, Bardin A, Lukinov V (2018) Increase of fire resistance limits of building structures of oil-and-gas complex under hydrocarbon fire. In: Energy management of municipal transportation facilities and transport, Springer, pp 818–82910.1007/978-3-319-70987-1_87 ↗
30. Li L, Purkiss JA, Tenchev RT (2002) An engineering model for coupled heat and mass transfer analysis in heated concrete. Proc Inst Mech Eng Part C J Mech Eng Sci 216(2):213–222. https://doi.org/10.1243/095440602152514210.1243/0954406021525142 ↗
31. Huang CLD, Ahmed GN, Fenton DL (1991) Responses of concrete walls to fire. Int J Heat Mass Transf 34(3):649–661. https://doi.org/10.1016/0017-9310(91)90113-S10.1016/0017-9310(91)90113-S ↗
32. Davie CT, Pearce CJ, Bićanić N (2006) Coupled heat and moisture transport in concrete at elevated temperatures—effects of capillary pressure and adsorbed water. Numer Heat Transf Part A Appl 49(8):733–763. https://doi.org/10.1080/1040778050050385410.1080/10407780500503854 ↗
33. Bažant ZP, Thonguthai W (1979) Pore pressure in heated concrete walls: theoretical prediction. Mag Concr Res 31(107):67–76. https://doi.org/10.1680/macr.1979.31.107.6710.1680/macr.1979.31.107.67 ↗
34. Huang CLD, Ahmed GN (1991) Influence of slab thickness on responses of concrete walls under fire. Numer Heat Transf Part A Appl 19(1):43–64. https://doi.org/10.1080/1040778910894483710.1080/10407789108944837 ↗
35. Šelih J, Sousa ACM, Bremner TW (1994) Moisture and heat flow in concrete walls exposed to fire. J Eng Mech 120(10):2028–2043. https://doi.org/10.1061/(ASCE)0733-9399(1994)120:10(2028)10.1061/(ASCE)0733-9399(1994)120:10(2028) ↗
36. Abdel-Rahman AK, Ahmed GN (1996) Computational heat and mass transport in concrete walls exposed to fire. Numer Heat Transf Part A Appl 29(4):373–395. https://doi.org/10.1080/1040778960891379810.1080/10407789608913798 ↗
37. Fu Y, Li L (2011) Study on mechanism of thermal spalling in concrete exposed to elevated temperatures. Mater Struct 44(1):361–376. https://doi.org/10.1617/s11527-010-9632-610.1617/s11527-010-9632-6 ↗
38. Harmathy TZ (1965) Effect of moisture on the fire endurance of building elements. In: Moisture in materials in relation to fire tests. ASTM International, p 7410.1520/STP48429S ↗
39. Ni S, Birely AC (2018) Impact of physical seismic damage on the fire resistance of reinforced concrete walls. Constr Build Mater 182:469–48210.1016/j.conbuildmat.2018.06.120 ↗
40. Al Fadul MA, Mackie KR (2018) Numerical analysis of coupled heat and mass transfer phenomena in concrete at elevated temperatures. Transp Porous Media 122(2):437–458. https://doi.org/10.1007/s11242-018-1017-210.1007/s11242-018-1017-2 ↗
41. Gawin D, Pesavento F, Schrefler BA (2003) Modelling of hygro-thermal behaviour of concrete at high temperature with thermo-chemical and mechanical material degradation. Comput Methods Appl Mech Eng 192(13–14):1731–1771. https://doi.org/10.1016/S0045-7825(03)00200-710.1016/S0045-7825(03)00200-7 ↗
42. Ahmed GN, Hurst JP (1999) Modeling pore pressure, moisture, and temperature in high-strength concrete columns exposed to fire. Fire Technol 35(3):232–262. https://doi.org/10.1023/A:101543651043110.1023/A:1015436510431 ↗
43. Ellingwood BR (1991) Impact of fire exposure on heat transmission in concrete slabs. J Struct Eng 117(6):1870–1875. https://doi.org/10.1061/(ASCE)0733-9445(1991)117:6(1870)10.1061/(ASCE)0733-9445(1991)117:6(1870) ↗
44. Schrefler BA, Majorana CE, Khoury GA, Gawin D (2002) Thermo-hydro-mechanical modelling of high performance concrete at high temperatures. Eng Comput 19(7):787–819. https://doi.org/10.1108/0264440021044432010.1108/02644400210444320 ↗
45. Harmathy TZ (1970) Moisture and heat transport with particular reference to concrete. Highw Res Rec 342
46. Sahota MS, Pagni PJ (1979) Heat and mass transfer in porous media subject to fires. Int J Heat Mass Transf 22(7):1069–1081. https://doi.org/10.1016/0017-9310(79)90180-710.1016/0017-9310(79)90180-7 ↗
47. Huang CLD, Siang HH, Best CH (1979) Heat and moisture transfer in concrete slabs. Int J Heat Mass Transf 22(2):257–266. https://doi.org/10.1016/0017-9310(79)90149-210.1016/0017-9310(79)90149-2 ↗
48. Jin Z-F, Asako Y, Yamaguchi Y (1998) Parametric study on thermal responses of a highly water content fire wall. Numer Heat Transf Part A Appl 33(4):403–414. https://doi.org/10.1080/1040778980891394610.1080/10407789808913946 ↗
49. Bamonte P, Gambarova P (2014) Properties of concrete subjected to extreme thermal conditions. J Struct Fire Eng10.1260/2040-2317.5.1.47 ↗
50. Wróblewska J, Kowalski R (2020) Assessing concrete strength in fire-damaged structures. Constr Build Mater 254:119122. https://doi.org/10.1016/j.conbuildmat.2020.11912210.1016/j.conbuildmat.2020.119122 ↗
51. Anderberg Y (1978) Fire-exposed hyperstatic concrete structures: an experimental and theoretical study. ACI Symp Publ 55:1978. https://doi.org/10.14359/662310.14359/6623 ↗
52. O’Meagher AJ, Bennetts ID (1991) Modelling of concrete walls in fire. Fire Saf J 17(4):315–335. https://doi.org/10.1016/0379-7112(91)90026-U10.1016/0379-7112(91)90026-U ↗
53. Hertz K (2018) Fire resistance of concrete walls with light aggregate. J Struct Fire Eng 9(4):319–341. https://doi.org/10.1108/JSFE-11-2017-004310.1108/JSFE-11-2017-0043 ↗
54. ASTM E119-20 (2020) Standard Test Methods for Fire Tests of Building Construction and Materials. ASTM International, West Conshohocken, www.astm.org, 2020, https://doi.org/10.1520/E0119-2010.1520/E0119-20 ↗
55. Eurocode 2 (2004) Design of concrete structures-Part 1–2: general rules-structural fire design. CEN Eur Comm Stand
56. Buchanan AH, Munukutla VR (1991) Fire resistance of load-bearing reinforced concrete walls. Fire Saf Sci 3:771–78010.3801/IAFSS.FSS.3-771 ↗
57. ACI Committee 318, Building Code Requirements for Structural Concrete (ACI 318-19): Commentary on Building Code Requirements for Structural Concrete (ACI 318R-19): an ACI Report. American Concrete Institute. ACI, 2019
58. Crozier DA, Sanjayan JG (2000) Tests of load-bearing slender reinforced concrete walls in fire. Struct J 97(2):243–251
59. Xiao J-Z, Li J, Jiang F (2004) Research on the seismic behavior of HPC shear walls after fire. Mater Struct 37(8):506–512. https://doi.org/10.1007/BF0248157410.1007/BF02481574 ↗
60. Liu G, Song Y, Qu F (2010) Post-fire cyclic behavior of reinforced concrete shear walls. J Cent South Univ Technol 17(5):1103–1108. https://doi.org/10.1007/s11771-010-0603-410.1007/s11771-010-0603-4 ↗
61. Liu GR, Qu FL, Song YP (2011) Temperatures measurements in reinforced concrete shear walls. Adv Mater Res 243–249:752–755. https://doi.org/10.4028/www.scientific.net/AMR.243-249.75210.4028/www.scientific.net/AMR.243-249.752 ↗
62. McGinnis MJ, Mueller KA, Kurama YC, Graham KP (2011) RC bearing walls subjected to elevated temperatures. Struct Congress, pp. 439–450 https://doi.org/10.1061/41171(401)3810.1061/41171(401)38 ↗
63. Go C-G, Tang J-R, Chi J-H, Chen C-T, Huang Y-L (2012) Fire-resistance property of reinforced lightweight aggregate concrete wall. Constr Build Mater 30:725–733. https://doi.org/10.1016/j.conbuildmat.2011.12.08110.1016/j.conbuildmat.2011.12.081 ↗
64. Lee C, Lee S, Kim H (2013) Experimental observations on reinforced concrete bearing walls subjected to all-sided fire exposure. Mag Concr Res 65(2):82–92. https://doi.org/10.1680/macr.12.0001310.1680/macr.12.00013 ↗
65. Lee S, Lee C (2013) Fire resistance of reinforced concrete bearing walls subjected to all-sided fire exposure. Mater Struct 46(6):943–957. https://doi.org/10.1617/s11527-012-9945-810.1617/s11527-012-9945-8 ↗
66. Tuan Ngo Priyan Mendis SF, Ta B (2013) Testing of normal- and high-strength concrete walls subjected to both standard and hydrocarbon fires. ACI Struct J 110(3):10. https://doi.org/10.14359/5168560710.14359/51685607 ↗
67. Nguyen KT, Ngo T, Mendis P, Heath D (2018) Performance of high-strength concrete walls exposed to fire. Adv Struct Eng 21(8):1173–1182. https://doi.org/10.1177/136943321773250010.1177/1369433217732500 ↗
68. Ni S, Birely AC (2014) Fire resistance of earthquake damaged reinforced concrete walls
69. Mueller KA, Kurama YC, McGinnis MJ (2014) Out-of-plane behavior of two reinforced concrete bearing walls under fire: a full-scale experimental investigation. ACI Struct J 111(5):1101–1110. https://doi.org/10.14359/5168681410.14359/51686814 ↗
70. Mueller KA, Kurama YC (2015) Out-of-plane behavior and stability of five planar reinforced concrete bearing wall specimens under fire. ACI Struct J 112(6):701–712. https://doi.org/10.14359/5168790810.14359/51687908 ↗
71. Miah MJ, Pinoteau N, Pimienta P (2016) A thermo mechanical experimental investigation on 3 loaded concrete walls exposed to ISO 834-1 Fire. Struct Fire
72. Bamonte P et al (2016) On the structural behavior of reinforced concrete walls exposed to fire. Key Eng Mater 711:580–58710.4028/www.scientific.net/KEM.711.580 ↗
73. Mueller KA, Kurama YC (2017) Out-of-plane behavior of reinforced concrete bearing walls after one-sided fire. ACI Struct J. https://doi.org/10.14359/5168944510.14359/51689445 ↗
74. Mohd Ali AZ, Sanjayan J, Guerrieri M (2017) Performance of geopolymer high strength concrete wall panels and cylinders when exposed to a hydrocarbon fire. Constr Build Mater 137:195–207. https://doi.org/10.1016/j.conbuildmat.2017.01.09910.1016/j.conbuildmat.2017.01.099 ↗
75. Morita T, Beppu M, Suzuki M (2017) An experimental study on the temperature and structural behavior of a concrete wall exposed to fire after a high-velocity impact by a hard projectile. Fire Saf J 91:506–516. https://doi.org/10.1016/j.firesaf.2017.03.02310.1016/j.firesaf.2017.03.023 ↗
76. Mohd Ali AZ, Sanjayan J, Guerrieri M (2017) Effect of aggregate size on the spalling of high-strength wall panels exposed to hydrocarbon fire. J Mater Civ Eng. https://doi.org/10.1061/(ASCE)MT.1943-5533.000208710.1061/(ASCE)MT.1943-5533.0002087 ↗
77. Morita T, Yamashita H, Beppu M, Suzuki M (2017) A study on structural behavior of reinforced concrete walls exposed to hydrocarbon fire under vertical load. In: Fire science and technology 2015, Singapore: Springer Singapore, pp 299–30810.1007/978-981-10-0376-9_30 ↗
78. Bleyer J, Pham DT, de Buhan P (2018) Numerical yield design analysis of high-rise reinforced concrete walls in fire conditions, in Advances in direct methods for materials and structures. Springer, Cham, pp 143–161
79. Ni S, Birely AC (2018) Simulation procedure for the post-fire seismic analysis of reinforced concrete structural walls. Fire Saf J 95:101–112. https://doi.org/10.1016/j.firesaf.2017.10.01110.1016/j.firesaf.2017.10.011 ↗
80. Guerrieri M, Fragomeni S (2019) Spalling of large-scale walls exposed to a hydrocarbon fire. J Mater Civ Eng 31(11):04019249. https://doi.org/10.1061/(ASCE)MT.1943-5533.000282810.1061/(ASCE)MT.1943-5533.0002828 ↗
81. Mueller KA, Kurama YC (2019) Numerical modeling of three reinforced concrete bearing wall tests subject to one-sided standard fire. ACI Struct J 116(5):29–4110.14359/51716756 ↗
82. Kang JY, Yoon HA, Ryu EM, Shin YS (2019) Analytical studies for the effect of thickness and axial load on load bearing capacity of fire damaged concrete walls with different sizes. J Struct Integr Maint 4(2):58–64. https://doi.org/10.1080/24705314.2019.160318910.1080/24705314.2019.1603189 ↗
83. Pothisiri T, Jongvivatsakul P, Chou S, Wijeyewickrema AC (2019) Modeling of precast concrete load-bearing walls exposed to fire. Eng J 23(6):433–449. https://doi.org/10.4186/ej.2019.23.6.43310.4186/ej.2019.23.6.433 ↗
84. Manica GC, Bolina FL, Tutikian BF, Oliveira M, Moreira MA (2020) Influence of curing time on the fire performance of solid reinforced concrete plates. J Mater Res Technol 9(2):2506–2512. https://doi.org/10.1016/j.jmrt.2019.12.08110.1016/j.jmrt.2019.12.081 ↗
85. Roy T, Matsagar V (2020) Fire fragility of reinforced concrete panels under transverse out-of-plane and compressive in-plane loads. Fire Saf J 113:102976. https://doi.org/10.1016/j.firesaf.2020.10297610.1016/j.firesaf.2020.102976 ↗
86. Kodur V (2014) Properties of concrete at elevated temperatures. ISRN Civ Eng 2014:1–15. https://doi.org/10.1155/2014/46851010.1155/2014/468510 ↗
87. du Plooy R, Palma Lopes S, Villain G, Dérobert X (2013) Development of a multi-ring resistivity cell and multi-electrode resistivity probe for investigation of cover concrete condition”. NDT E Int 54:27–36. https://doi.org/10.1016/j.ndteint.2012.11.00710.1016/j.ndteint.2012.11.007 ↗
88. Abrams MS, Gustaferro AH (1968) Fire endurance of concrete slabs as influenced by thickness, aggregate type, and moisture
89. Jowsey A, Torero JL, Usmani A (2004) Modelling of structures in fire: an example of the boundary condition. Int Tech Congr Comput Simul Fire Model Eng Res
90. Lakhani H, Kamath P, Bhargava P, Sharma U, Reddy G (2013) Thermal analysis of reinforced concrete structural elements. J Struct Fire Eng 4(4):227–244. https://doi.org/10.1260/2040-2317.4.4.22710.1260/2040-2317.4.4.227 ↗
91. Tamrazyan A, Avetisyan L (2014) Estimation of load bearing capacity of eccentrically compressed reinforced concrete elements under dynamic loading in fire conditions. Appl Mech Mater 638–640:62–65. https://doi.org/10.4028/www.scientific.net/AMM.638-640.6210.4028/www.scientific.net/AMM.638-640.62 ↗
92. Kodur V, Hibner D, Agrawal A (2017) Residual response of reinforced concrete columns exposed to design fires. Proc Eng 210:574–581. https://doi.org/10.1016/j.proeng.2017.11.11610.1016/j.proeng.2017.11.116 ↗
93. Lin C-H, Chen S-T, Yang C-A (1995) Repair of fire-damaged reinforced concrete columns. Struct J 92(4):406–411
94. Jansson R (2013) Fire spalling of concrete: a historical overview. MATEC Web Conf 6:01001. https://doi.org/10.1051/matecconf/2013060100110.1051/matecconf/20130601001 ↗
95. Boström L, Jansson R (2011) The age effect on fire spalling of concrete. 2nd Int RILEM Workshop on Concrete Spalling due to Fire Exposure 1:33–41
96. Witek A, Gawin D, Pesavento F, Schrefler BA (2006) Finite element analysis of various methods for protection of concrete structures against spalling during fire. Comput Mech 39(3):271–292. https://doi.org/10.1007/s00466-005-0024-710.1007/s00466-005-0024-7 ↗
97. Malhotra HL (1984) Spalling of concrete in fires. CIRIA
98. Ali F (2002) Is high strength concrete more susceptible to explosive spalling than normal strength concrete in fire? Fire Mater 26(3):127–130. https://doi.org/10.1002/fam.79110.1002/fam.791 ↗
99. Krzemień K, Hager I (2015) Assessment of concrete susceptibility to fire spalling: a report on the state-of-the-art in testing procedures. Proc Eng 108:285–292. https://doi.org/10.1016/j.proeng.2015.06.14910.1016/j.proeng.2015.06.149 ↗
100. Liu J-C, Tan KH, Yao Y (2018) A new perspective on nature of fire-induced spalling in concrete. Constr Build Mater 184:581–590. https://doi.org/10.1016/j.conbuildmat.2018.06.20410.1016/j.conbuildmat.2018.06.204 ↗