journal article·2004-04

How Many People are Exposed to Sublethal Fire Smoke?

John R. Hall

Fire Technology· Volume 40· Issue 2
Publisher page

Abstract

A good estimate of the magnitude of the population exposed to fire smoke would be a reality check on the suitability of predicting harm to people from fire through the use of conservatively low fire safety thresholds designed to assure no harm to even vulnerable subpopulations. If this total number of exposed people were far greater than the number of reported victims, then it would be fair to say that the implied safety factors in such a calculation are unreasonably large. Based on analyses of demographic and fire incidence data, it is estimated that between 310,000 and 670,000 people (excluding firefighters) in the U.S. are exposed to fire smoke each year in unwanted home fires alone. This compares to an average of 3,318 home civilian fire deaths and 11,505 civilian fire injuries per year involving smoke inhalation in part or in whole in reported home fires. There are thus 21 to 45 civilians exposed to toxic fire smoke per year for every one with a reported fire injury involving smoke inhalation. It is likely that most of these exposures are brief or are to the dilute smoke that is present outside the room of fire origin, where most survivors are located, and do not result in any noticeable consequences, let alone injury or death.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Injury Epidemiology and Prevention · Traffic and Road Safety

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (12)

Show source-provided references
1. Statistical Abstract of the United States: 2001, 121st edition,Washington: U.S. Census Bureau, 2001, Table 1.
2. Michael J. Karter, Jr., “U.S. Fire Loss of 2000,” NFPA Journal, September/October 2001, pp. 80ff.
3. Michael J. Karter, Jr., and Stephen G. Badger, “U.S. Firefighter Injuries of 2000,” NFPA Journal, November/December 2001, pp. 49ff.
4. S.D. Christian, “Safe Tolerability Limits for Carbon Monoxide? A Review of the Clinical and Fire Engineering Implications of a Single, Acute, Sub-lethal Exposure,” Interflam '99 conference proceedings, London: Interscience Communications, Ltd., 1999, pp. 709–722.
5. ISO CD 13571 (since adopted in somewhat modified form as a Technical Specification(TS)), Fire hazard analysis-Life threat components of fire, Geneva, Switzerland: ISO, 2001.
6. Analysis by S.W. Stiefel of U.S. Census Bureau data, as published in R.W. Bukowski et al., Fire Risk Assessment Method: Case Study 1: Upholstered Furniture in Residences, National Fire Protection Research Foundation, Quincy, MA (1990), pp. 24–31.
7. Statistical Abstract of the United States: 2001, 121st edition, Washington: U.S. Census Bureau, 2001, Tables 12 and 54.
8. Statistical Abstract of the United States: 2001, 121st edition, Washington: U.S. Census Bureau, 2001, Table 579.
9. Hall, Jr., J.R., Patterns of Fire Casualties in Home Fires by Age and Sex, Quincy, MA: NFPA Fire Analysis & Research Division, April 2000.
10. 1984 National Sample Survey of Unreported Residential Fires: Final Technical Report, prepared for U.S. Consumer Product Safety Commission, Contract No. C-83-1239, Audits & Surveys, Inc., Princeton, NJ, (1985).
11. Michael J. Karter, Jr., U.S. fire loss articles on 1993-97 fire experience, NFPA Journal, September/October, 1994-98.
12. Marty Ahrens, U.S. Experience with Smoke Alarms, Quincy, MA: NFPA Fire Analysis & Research Division, September 2001