An Evaluation of the International Maritime Organization's Gaseous Agents Test Protocol
Source abstract
Abstract
The International Maritime Organization (IMO) Maritime Safety Committee's (MSC) subcommittee on fire protection (FP) has developed a test protocol for evaluating the extinguishing effectiveness and critical design parameters of fixed gaseous halon alternative fire extinguishing systems. This paper is an evaluation of the developed protocol based upon its effectiveness in verifying agent distribution throughout the protected space and the effectiveness of the agent against typical maritime fire scenarios. The testing described herein was conducted by the U.S. Coast Guard as part of their evaluation of the developed protocol. Four “halocarbon” agents (NAF-SIII, CEA-410, CEA-308 and FM-200), one “inert” agent (Inergen), one gas/powder mix (Envirogel), and Halon 1301 for baseline comparisons were evaluated with the protocol. The IMO Protocol was found to represent a reasonable basis for evaluating the effectiveness of fixed gaseous fire extinguishing systems. However, the results from testing with the protocol are subject to interpretation due to the lack of a definition of the end of the discharge time. The four fire scenarios that make up the protocol can better meet their respective objectives by modifying the scenarios to reduce the impact on extinguishment of variables other than the uniform addition of agent throughout the space (e.g., oxygen depletion, localized high agent concentrations, and localized high flow velocities).
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Risk and Safety Analysis · Combustion and Detonation Processes · Fire dynamics and safety research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (18)
Show source-provided references
1. International Maritime Organization, “Guidelines for Approval of Equivalent Gas Fire-Extinguishing Systems, as Referred to in SOLAS 74, for Machinery Spaces and Cargo Pump-Rooms,” Annex to IMO Maritime Safety Committee Circular 848, June 8, 1998.
2. G.G. Back, C.L. Be yler, P.J. DiNenno, E.W. Forssell, M.J. Peatross, R. Hansen, D. Waller, and R. Zalosh, “An Evaluation of the International Maritime Organization' Gaseous Agents Test Protocol,” Report No.CG-D–24–97, United States Coast Guard, Marine Fire and Safety Research Branch, October 1997.
3. G.G.Back, E.W. Forssell, C.L. Beyler, P.J. DiNenno, R. Hansen, and D. Beene, “An Evaluation of the International Maritime Organization' Gaseous Agents Test Protocol with Halocarbon Agents and an Inert Gas, 180 Degree Nozzles, and Low Temperature Conditioned Cylinders,” Report No.CG-D–02–99, United States Coast Guard, Marine Fire and Safety Research Branch, December 1998.
4. “ISO/14520 Draft International Standard of Gaseous Fire Extinguishing Systems,” Part 1 Annex B, Standards Association of Australia, Strathfield, NSW, Australia.
5. NFPA, “Standard on Clean Agent Fire Extinguishing Systems,” NFPA 2001, 2000 ed., National Fire Protection Association, Quincy, MA, 2000.
6. P. Rivers, 3M Company, personal communications, 1999.
7. NFPA, “Standard on Halon 1301 Fire Extinguishing Systems,” NFPA 12A, 1980 ed., National Fire Protection Association, Quincy, MA, 1980.
8. E.J. Henley and J.D. Seader, Equilibrium-Stage Separation Operations in Chemical Engineering. New York: John Wiley & Sons, 1981.
9. R.C. Reid, J.M. Prausnitz, and T.K. Sherwood, The Properties of Gases and Liquids, 3rded., New York: McGraw-Hill Book Company, 1977.
10. R. Hansen, R. Richards, G.G. Back, and T. Moore, “USCG Full-scale Shipboard Testing of Gaseous Agents,” 1994 International CFC and Halon Alternatives Conference Proceedings, Washington, DC, October 24- 26, 1994.
11. E.W. Forssell and P.J. DiNenno, “Evaluation of Alternative Agents for Use in Total Flooding Fire Protection Systems,” NASA SBIR Phase II Final Report, National Aeronautics and Space Administration, Kennedy Space Center, FL, 1994.
12. A.K. Kim and J.Z. Su, “Full-Scale Evaluation of Halon Replacement Agents,” Journal of Fire Protection Engineering, vol.10, no.2, 1999.10.1177/104239159901000201 ↗
13. P.J. DiNenno and E.W. Forssell, “An Evaluation of Perfluorocarbons as Fire Suppression Agents,” NASA SBIR Phase I Final Report, National Aeronautics and Space Administration, Kennedy Space Center, FL, 1991.
14. D.M. Tucker, D.D. Drysdale, and D.J. Rasbash, “The Extinction of Diffusion Flames Burning in Various Oxygen Concentrations by Inert Gases and Bromotrifluoromethane,” Combustion and Flame, vol.41, 1981.10.1016/0010-2180(81)90063-8 ↗
15. W. Dumayas, “The Effects of Corrosive Thermal Decomposition Products on Input/Output Cards, Produced When Halon Alternatives Are Used to Extinguish a Heptane Fuel Fire,” Senior Research Project, University of Maryland, College Park, 1993.
16. “Hazard Assessment of Thermal Decomposition Products of FM-200TM in Electronics and Data Processing Industries,” Hughes Associates, Inc., Columbia, MD, 1995.
17. M.D. Pedley, “Corrosion of Typical Orbiter Electronic Components Exposed to Halon 1301 Pyrolysis Products,” TR-339–001, NASA, White Sands Test Facility, Las Cruces, NM, 1985.
18. M. Meldrum, Toxicology of Substances in Relation to Major Hazards: Hydrogen Fluoride. London: HMSO, 1993.