Real-Time Forecasting of Building Fire Growth and Smoke Transport via Ensemble Kalman Filter
Source abstract
Abstract
Forecasting building fire growth and smoke dispersion is a challenging task but can provide early warnings to first responders and building occupants and thus significantly benefit active building fire protection. Although existent computer simulation models may provide acceptable estimations of smoke temperature and quantity, most simulations are still not able to achieve real-time forecast of building fire due to high computational requirements, and/or simulation accuracy subject to users’ inputs. This paper investigates one of the possibilities of using ensemble Kalman filter (EnKF), a statistical method utilizing the real-time sensor data from thermocouple trees in each room, to estimate the spread of an accidental building fire and further forecast smoke dispersion in real time. A general approach to forecasting building fire and smoke is outlined and demonstrated by a 1:5 scaled compartment fire experiment using a 1.0 kW to 2.8 kW propane burner as fire source. The results indicate that the EnKF method is able to forecast smoke transport in a multi-room building fire using 40 ensemble members and provide noticeable accuracy and lead time. Unlike other methods that directly use measurement data as model inputs, the developed model is able to statistically update model parameters to maintain the forecasting accuracy in real time. The results obtained from the model can be potentially applied to assist mechanical smoke removal, emergency evacuation and firefighting.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Wind and Air Flow Studies · Fire dynamics and safety research · Fire effects on ecosystems
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (19)
Show source-provided references
1. Cowlard A, Jahn W, Abecassis-Empis C, Rein G, Torero JL (2010) Sensor assisted fire fighting. Fire Technol 46:719–741. doi: 10.1007/s10694-008-0069-110.1007/s10694-008-0069-1 ↗
2. Yang D, Hu LH, Jiang YQ, Huo R, Zhao XY (2010) Comparison of FDS predictions by different combustion models with measured data for enclosure fires. Fire Saf J 45:298–313. doi: 10.1016/j.firesaf.2010.06.00210.1016/j.firesaf.2010.06.002 ↗
3. Koo S-H, Fraser-Mitchell J,Welch S (2010) Sensor-steered fire simulation. Fire Saf J 45(3):193–205. doi: 10.1016/j.firesaf.2010.02.00310.1016/j.firesaf.2010.02.003 ↗
4. Jahn W, Rein G, Torero J. (2011) Forecasting fire growth using an inverse zone modelling approach. Fire Safety J 46(3):81–88. doi: 10.1016/j.firesaf.2010.10.00110.1016/j.firesaf.2010.10.001 ↗
5. Jahn W, Rein G, Torero J. (2012) Forecasting fire dynamics using inverse computational fluid dynamics and tangent linearisation. Advances in Engineering Software 47(1):114–126. doi: 10.1016/j.advengsoft.2011.12.00510.1016/j.advengsoft.2011.12.005 ↗
6. Beji, T., Verstockt, S., Van de Walle, R. and Merci, B. (2014) On the use of real-time video to forecast fire growth in enclosures. Fire Technol 50(4):1021–1040. doi: 10.1007/s10694-012-0262-010.1007/s10694-012-0262-0 ↗
7. Overholt, K. J. and Ezekoye, O. (2012) Characterizing heat release rates using an inverse fire modeling technique. Fire Technol 48(4):893–909. doi: 10.1007/s10694-011-0250-910.1007/s10694-011-0250-9 ↗
8. Overholt, K. J. and Ezekoye, O. (2014) Quantitative testing of fire scenario hypotheses: a bayesian inference approach. Fire Technol 51(2):335–367. doi: 10.1007/s10694-013-0384-z10.1007/s10694-013-0384-z ↗
9. M. Price and A. Trouvé (2015) A Multi-observable approach to address the Ill-posed nature of inverse fire modeling problems. Fire Technol. doi: 10.1007/s10694-015-0541-710.1007/s10694-015-0541-7 ↗
10. Lin C-C, Wang L (2013) Forecasting simulations of indoor environment using data assimilation via an Ensemble Kalman Filter. Build Environ 64:169–176. doi: 10.1016/j.buildenv.2013.03.00810.1016/j.buildenv.2013.03.008 ↗
11. Heskestad G (1984) Engineering relations for fire plumes. Fire Saf J 7:25–32. doi: 10.1016/0379-7112(84)90005-510.1016/0379-7112(84)90005-5 ↗
12. Tanaka T (1983) A model of multiroom fire spread. Fire Sci Technol 3:105–121. doi: 10.3210/fst.3.10510.3210/fst.3.105 ↗
13. Peacock RD, Davis S, Lee BT (1988) Experimental data set for the accuracy assessment of room fire models. National Bureau of Standards 88-3752.10.6028/NBS.IR.88-3752 ↗
14. Peacock RD, Reneke PA (2007) Verification and validation of selected fire models for nuclear power plant applications. Vol. 5. Consolidated fire growth and smoke transport model (CFAST). NUREG-1824, US Nuclear Regulatory Commission, Washington, DC.
15. Ji J, Li M, Li K, Yuan M, Sun J (2015) Ambient wind effect on combustion characteristcs in compartment with simutaneous door and window opened. Energy Build 105:217–225. doi: 10.1016/j.enbuild.2015.07.04610.1016/j.enbuild.2015.07.046 ↗
16. Evensen G (1994) Sequential Data Assimilation with a Non-Linear Quasi-Geostrophic Model Using Monte Carlo Methods to Forecast Error Statistics. J Geophys Res 99:10,143-10,162. doi: 10.1029/94JC0057210.1029/94JC00572 ↗
17. Lin C-C, Wang LL (2015) Forecasting smoke transport during compartment fires using a data assimilation model. J Fire Sci 33(1):3–21. doi: 10.1177/073490411454883710.1177/0734904114548837 ↗
18. Hamill TM, Whitaker JS (2001) Distance-dependent filtering of background error covariance estimates in an ensemble Kalman filter. Mon Weather Rev 129:2276-2790. Doi: 10.1175/1520-0493(2001)129<2776:DDFOBE>2.0.CO;210.1175/1520-0493(2001)129<2776:DDFOBE>2.0.CO;2 ↗
19. Houtekamer PL, Mitchell HL (2001) A sequential ensemble Kalman filter for atmospheric data assimilation. Mon Weather Rev 129:123–137. doi: 10.1175/1520-0493(2001)129<0123:ASEKFF>2.0.CO;210.1175/1520-0493(2001)129<0123:ASEKFF>2.0.CO;2 ↗