An Experimental Study on Fire Suppression Devices for Power Batteries of Hybrid Electric Multiple Units

Zheng Li, Yao Fu, Aiqun Liu, Xuefei Li, Guangtai Chen, Peng Qin

Fire Technology· Volume 59· Issue 3
Publisher page

Abstract

The hybrid type electric multiple units (EMUs) are generally equipped with LiCoO2/Li4Ti5O12 lithium-titanate (LTO) batteries. LTO batteries are often in a state of high-rate charging and discharging since they are mainly used for emergency traction and braking recycling of EMUs. Under such operating conditions, LTO batteries have a higher risk of thermal runaway, which would induce battery fires in the operation and lead to grave consequences. In this paper, a fire suppression device containing a fire detection tube was proposed for the power battery system of hybrid EMUs. Meanwhile, experiments were conducted to detect thermal runaway of the single battery and thermal expansion of the battery module installed with the fire suppression device. The fire detection tube was filled with clean agent Dodecafluoro-2-methylpentan-3-one. During the experiment, when triggering the process of thermal runaway, the fire suppression device prevented the battery from catching on fire successfully. Moreover, the fire suppression device had good cooling performance. The thermal runaway temperature of the battery with the fire suppression device installed was lowered to 130°C or so, compared with 550°C of the single battery alone. The fire suppression device was then installed in the battery system of a hybrid EMU, which performed well in operation.
Source: expertdata · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Advanced Battery Technologies Research · Internet of Things and Social Network Interactions · Fire dynamics and safety research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (24)

Show source-provided references
1. Tian R, Kang Y (2012) Development of hybrid electric locomotive at home and abroad. Diesel Locomot 10:1–4
2. Wang W, Ruan H (2014) Research and development of CFH330 narrow gauge petrol-electric hybrid locomotive. Railw Locomot Bull Train 11:14–16
3. Zhang X, Tian Y, Zhang X (2012) Research on power system modeling and energy management of hybrid electric locomotive. J China Railw Soc 34:20–25
4. Tian R, Kang Y (2012) Development of hybrid electric locomotive at home and abroad. Diesel Locomot 9:1–4
5. Li X, Wang Z, Ma Z (2013) Battery system design of dual power EMUS based on lithium ion battery. China Railw 7:73–77
6. Ramadass P (2003) Capacity fade analysis of commercial Li-ion batteries. Dissertation, University of South Carolina
7. Zhang S, Xu K et al (2006) Charge characteristics of a commercial LICoo2-based 18650 battery. J Power Sources 160:1403–140910.1016/j.jpowsour.2006.03.037 ↗
8. Zheng X (2007) Lithium-ion battery electrolyte. Chemical Industry Press, Beijing
9. Wang Z, Gong M (2011) Lithium titanate battery management system for EMU. China Railw 12:64–66
10. Wu J (2015) Simulation platform for hybrid electric EmU power integration scheme design and evaluation. Dissertation, Southwest Jiaotong University
11. Feng X, He X, Ouyang M, Lu L, Wu P, Kulp C et al (2015) Thermal runaway propagation model for designing a safer battery pack with 25Ah LiNixCoyMnzO2 large format lithium ion battery. Appl Energy 154:74–9110.1016/j.apenergy.2015.04.118 ↗
12. Liu P, Li Y, Mao B, Chen M, Huang Z, Wang Q (2021) Experimental study on thermal runaway and fire behaviors of large format lithium iron phosphate battery. Appl Therm Eng 192:11694910.1016/j.applthermaleng.2021.116949 ↗
13. Mao B, Liu C, Yang K, Li S, Liu P, Zhang M et al (2021) Thermal runaway and fire behaviors of a 300 Ah lithium ion battery with LiFePO4 as cathode. Renew Sustain Energy Rev 139:11071710.1016/j.rser.2021.110717 ↗
14. Ren D, Feng X, Liu L, Hsu H, Lu L, Wang L et al (2021) Investigating the relationship between internal short circuit and thermal runaway of lithium-ion batteries under thermal abuse condition. Energy Storage Mater 34:563–57310.1016/j.ensm.2020.10.020 ↗
15. Plunkett ST, Chen C, Rojaee R, Doherty P, Sik OhY, Galazutdinova Y et al (2021) Enhancing thermal safety in lithium-ion battery packs through parallel cell ‘current dumping’ mitigation. Appl Energy 286:11649510.1016/j.apenergy.2021.116495 ↗
16. Richter M, Sarram A, Kaucher C, Winkler H (2019) Investigation and analysis of accumulators for the use of electrochemical storage in hybrid shunting locomotives. Procedia CIRP 81:1010–101510.1016/j.procir.2019.03.243 ↗
17. Egelhaaf M, Kress D, Wolpert D et al (2013) Fire fighting of Li-ion traction batteries. SAE Int J Altern Powertrains 2:37–4810.4271/2013-01-0213 ↗
18. Liu Y, Duan Q, Xu J et al (2018) Experimental study on the efficiency of dodecafluoro-2-methylpentan-3-one on suppressing lithium-ion battery fires. RSC Adv 8:42223–4223210.1039/C8RA08908F ↗
19. Liu T, Tao C, Wang X (2020) Cooling control effect of water mist on thermal runaway propagation in lithium ion battery modules. Appl Energy 267:11508710.1016/j.apenergy.2020.115087 ↗
20. Liu Y, Duan Q, Xu J et al (2020) Experimental study on a novel safety strategy of lithium-ion battery integrating fire suppression and rapid cooling. J Energy Storage 28:10118510.1016/j.est.2019.101185 ↗
21. Zhang L, Li Y, Duan Q et al (2020) Experimental study on the synergistic effect of gas extinguishing agents and water mist on suppressing lithium-ion battery fires. J Energy Storage 32:10180110.1016/j.est.2020.101801 ↗
22. Wang H, Tang A, Wang K (2011) Thermal behavior investigation of LiNi1/3Co1/3Mn1/3O2-based Li-ion battery under overcharged test. Chin J Chem 29:27–3210.1002/cjoc.201190056 ↗
23. Du Pasquier A, Disma F, Bowmer T, Gozdz AS, Amatucci G, Tarascon JM (1998) Differential scanning calorimetry study of the reactivity of carbon anodes in plastic Li-ion batteries. J Electrochem Soc 145:472–47710.1149/1.1838287 ↗
24. Shin J, Han C, Jung U, Lee S, Kim H, Kim K (2002) Effect of Li2CO3 additive on gas generation in lithium-ion batteries. J Power Sources 109:47–5210.1016/S0378-7753(02)00039-3 ↗