journal article·2019-01

Graphene/polyethylene glycol hybrids for single-step immunoassay microdevice

Akihiro Shirai, Kenji Sueyoshi, Tatsuro Endo, Hideaki Hisamoto

FlatChem· Volume 13
Publisher page

Abstract

Abstract In this study, we developed a novel particle-type material comprised of graphene and polyethylene glycol (PEG) to solve the slow response problem of the previously reported microdevice for single-step immunoassay. Characterization of these graphene/PEG hybrids (GPH) was carried out using a transmission electron microscopy (TEM), Fourier transform infrared (FT-IR) spectroscopy, and fluorescence analysis. We found that PEG attached to graphene surfaces behave like molecular sieves to separate free fluorescently-labeled antibodies from antigen-bound antibody immunocomplexes. The free antibody is PEG-permeable and directly adsorbs onto the graphene surface, where fluorescence is quenched by fluorescence resonance energy transfer. On the contrary, immunocomplexes are PEG-impermeable; thus, as the concentration of the antigen increases, the concentration of PEG-impermeable immunocomplexes also increases; consequently, increasing the fluorescence intensity of the solution. After characterizing GPH, single-step immunoassay microdevices were prepared by separately immobilizing the GPH and fluorescently-labeled antibodies on two independent microchannel arrays and combining them. Finally, we tested the proposed immunoassay microdevices with various known concentrations of C-reactive protein (CRP), an inflammatory marker protein, and successfully measured CRP concentration within an approximate time of 2 min by monitoring the fluorescence intensity change.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Biosensors and Analytical Detection · Advanced biosensing and bioanalysis techniques · Microfluidic and Capillary Electrophoresis Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (53)

Show source-provided references
1. Point of care diagnostics: status and future10.1021/ac2030199 ↗
2. Point-of-care testing for infectious diseases: past, present, and future10.1128/JCM.00476-17 ↗
3. An integrated microfluidic platform for sensitive and rapid detection of biological toxins10.1039/b815152k ↗
4. Simultaneous detection and high-throughput identification of a panel of RNA viruses causing respiratory tract infections10.1128/JCM.00210-07 ↗
5. Point-of-care testing of proteins10.1007/s00216-008-2572-0 ↗
6. Clinical chemistry: challenges for analytical chemistry and the nanosciences from medicine10.1002/anie.200903363 ↗
7. Immunoassays in microfluidic systems10.1007/s00216-010-3678-8 ↗
8. Inkjet nanoinjection for high-thoughput chemiluminescence immunoassay on multicapillary glass plate10.1021/ac4013336 ↗
9. Wax-assisted one-step enzyme-linked immunosorbent assay on lateral flow test devices10.2116/analsci.34.51 ↗
10. Rapid enzyme-linked immunosorbent assays for diagnosis of diabetes in a compact disc-shaped microfluidic device10.2116/analsci.34.379 ↗
11. Microfluidics-based diagnostics of infectious diseases in the developing world10.1038/nm.2408 ↗
12. A paper-based multiplexed transaminase test for low-cost, point-of-care liver function testing10.1126/scitranslmed.3003981 ↗
13. Highly sensitive paper-based analytical devices with the introduction of a large-volume sample via continuous flow10.2116/analsci.34.65 ↗
14. Microfluidic paper-based analytical device for the determination of hexavalent chromium by photolithographic fabrication using a photomask printed with 3D printer10.2116/analsci.34.71 ↗
15. Microfluidic paper-based analytical devices for determination of creatinine in urine samples10.2116/analsci.34.109 ↗
16. Paper-based microfluidic point-of-care diagnostic devices10.1039/c3lc50169h ↗
17. Laminated paper-based analytical devices (LPAD) with origami-enabled chemiluminescence immunoassay for cotinine detection in mouse serum10.1021/ac402055n ↗
18. Flow-enhanced electrochemical immunosensors on centrifugal microfluidic platforms10.1039/c3lc50374g ↗
19. Capillary-assembled microchip for universal integration of various chemical functions onto a single microfluidic device10.1021/ac035385t ↗
20. Integration of multianalyte sensing functions on a capillary-assembled microchip: simultaneous determination of ion concentrations and enzymatic activities by a “drop-and-sip” technique10.1021/ac061245i ↗
21. Enzyme-release capillary as a facile enzymatic biosensing part for a capillary-assembled microchip10.2116/analsci.25.1025 ↗
22. Open-type capillary-assembled microchip for rapid, single-step, simultaneous multi-component analysis of serum sample10.1039/c2ra21843g ↗
23. Facile preparation method of a disposable capillary biosensor using an ion-selective optode membrane and a dissolvable enzyme membrane and its application to urea sensing10.1246/cl.2010.436 ↗
24. Advancements in capillary-assembled microchip (CAs-CHIP) development for multiple analyte sensing and microchip electrophoresis10.2116/analsci.30.7 ↗
25. Fabrication and packaging of a mass-producible capillary-assembled microchip for simple and multiplexed bioassay10.1016/j.snb.2015.05.001 ↗
26. Combinable poly(dimethyl siloxane) capillary sensor array for single-step and multiple enzyme inhibitor assays10.1039/C1LC20651F ↗
27. Bulk- and surface-modified combinable PDMS capillary sensor array as easy-to-use sensing device with enhanced sensitivity to elevated concentrations of multiple serum sample components10.1039/c2lc21242k ↗
28. Integration of neuraminidase inhibitor assay into a single-step operation using combinable poly(dimethylsiloxane) capillary sensor10.1039/c3an36785a ↗
29. Efficient immobilization of enzyme and substrate for single-step caspase-3 inhibitor assay using combinable PDMS capillary sensor array10.1039/C3RA46976J ↗
30. Fast and single-step fluorescence-based competitive bioassay microdevice using combined PDMS microchannel arrays separately immobilizing graphene oxide-analyte conjugates and fluorescently-labelled receptor proteins10.2116/analsci.33.969 ↗
31. Regioselective immobilization of PVC membrane composed of ionic liquid-based dye on convex-shaped PDMS surface for multiplexed microanalytical devices10.2116/analsci.18C008 ↗
32. Design of single-step immunoassay principle based on the combination of enzyme-labeled antibody release coating and hydrogel copolymerized with fluorescent enzyme substrate in a microfluidic capillary device10.1039/c3lc50775k ↗
33. A single-step enzyme immunoassay capillary sensor composed of functional multilayer coatings for diagnosis marker proteins10.1039/C4AN01781A ↗
34. Fast and single-step immunoassay based on fluorescence quenching within a square glass capillary immobilizing graphene oxide-antibody conjugate and fluorescently labelled antibody10.1039/C5AN02637G ↗
35. Development of a single-step immunoassay microdevice based on a graphene oxide-containing hydrogel possessing fluorescence quenching and size separation functions10.1039/C6AN02485H ↗
36. Epitaxial two-layer graphene under pressure: diamene stiffer than diamond10.1016/j.flatc.2018.08.001 ↗
37. Stretchable electronic devices using graphene and its hybrid nanostructures10.1016/j.flatc.2017.06.002 ↗
38. Graphene-CdSe quantum dot hybrid as a platform for the control of carrier temperature10.1016/j.flatc.2017.08.007 ↗
39. Sweet graphene quantum dots for imaging carbohydrate receptors in live cells10.1016/j.flatc.2017.08.006 ↗
40. Graphene oxide arrays for detecting specific DNA hybridization by fluorescence resonance energy transfer10.1016/j.bios.2010.02.022 ↗
41. Fluorescence resonance energy transfer between quantum dots and graphene oxide for sensing biomolecules10.1021/ac100852z ↗
42. A novel fluorescent biosensor for sequence-specific recognition of double-stranded DNA with the platform of graphene oxide10.1039/c1an15061h ↗
43. A versatile graphene-based fluorescence “on/off” switch for multiplex detection of various targets10.1016/j.bios.2010.12.037 ↗
44. Detection of lead (II) with a “turn-on” fluorescent biosensor based on energy transfer from CdSe/ZnS quantum dots to graphene oxide10.1016/j.bios.2012.11.039 ↗
45. A molecular beacon and graphene oxide-based fluorescent biosensor for Cu2+ detection10.1016/j.bios.2012.12.056 ↗
46. A graphene oxide platform for energy transfer-based detection of protease activity10.1016/j.bios.2011.03.003 ↗
47. A graphene oxide-based FRET sensor for rapid and sensitive detection of matrix metalloproteinase 2 in human serum sample10.1016/j.bios.2013.03.030 ↗
48. Graphene oxide–peptide nanocomplex as a versatile fluorescence probe of protein kinase activity based on phosphorylation protection against carboxypeptidase digestion10.1021/ac400336u ↗
49. Distance-independent quenching of quantum dots by nanoscale-graphene in self-assembled sandwich immunoassay10.1039/c0cc02085k ↗
50. General approach for monitoring peptide–protein interactions based on graphene–peptide complex10.1021/ac200617k ↗
51. Simultaneous determination of human enterovirus 71 and coxsackievirus B3 by dual-color quantum dots and homogeneous immunoassay10.1021/ac203172x ↗
52. Graphene-based chemiluminescence resonance energy transfer for homogeneous immunoassay10.1021/nn300684d ↗
53. Poly(vinyl alcohol)-encapsulated hydrophilic carbon black nanoparticles free from aggregation10.1002/marc.200350017 ↗