journal article·2023-06-01Open access

Flexible planar capacitive devices for hydration and sweat sensing

Shayan Naveed, Ma Jinzhong, Shazrah Shahzad, Xiaoming Wu, Tianling Ren

Abstract

Abstract Skin is one of the most complex structures in the body, with many physiological functions. Skin acts as the barrier or an interface between the external environment and internal organs. Hydration within the skin is varied, known as the skin’s water-loading. Perspiration occurs when watery fluid is secreted through the eccrine and apocrine glands. Flexible epidermal sensors are fabricated, which can be used to measure skin hydration and perspiration (sweat) as these sensors need to be skin-conformable. Polyimide and polydimethylsiloxane are used as they are flexible and skin compliant, and the sensing layer is formed on them. The sensitivity of hydration sensors was in the range of 0.002–0.0046/%, while for sweat sensors, it was in the range of 0.092–0.116 μl−1. Stability tests indicated that external factors such as environment or physical deformation and skin curvature do not affect the performance of the as-prepared sensors. The sensitivity and stability results of the planar capacitor are highly suitable for flexible hydration and sweat-sensing applications. The proposed sensors offer an outstandingly good option for incorporation into wearable systems for physical personal health monitoring. In the future, we plan to integrate these sensors on a single substrate to create a multimodal device.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Advanced Sensor and Energy Harvesting Materials · Tactile and Sensory Interactions · Dielectric materials and actuators

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (45)

Show source-provided references
1. Body fluid volumes measurements by impedance: a review of bioimpedance spectroscopy (BIS) and bioimpedance analysis (BIA) methods10.1016/j.medengphy.2008.06.009 ↗
2. Wearable sweat sensors10.1038/s41928-018-0043-y ↗
3. Houglum · 2011
4. Wearable strain sensor for real-time sweat volume monitoring10.1016/j.isci.2020.102028 ↗
5. Battery-free, skin-interfaced microfluidic/electronic systems for simultaneous electrochemical, colorimetric, and volumetric analysis of sweat10.1126/sciadv.aav3294 ↗
6. A wearable paper-based sweat sensor for human perspiration monitoring10.1002/adhm.201900342 ↗
7. Ultra-simple wearable local sweat volume monitoring patch based on swellable hydrogels10.1039/C9LC00911F ↗
8. Thin film non-symmetric microelectrode array for impedance monitoring of human skin10.1016/S0040-6090(03)00389-4 ↗
9. Reliable, low-cost, fully integrated hydration sensors for monitoring and diagnosis of inflammatory skin diseases in any environment10.1126/sciadv.abd7146 ↗
10. Epidermal differential impedance sensor for conformal skin hydration monitoring10.1007/s13758-012-0052-8 ↗
11. Epidermal impedance sensing sheets for precision hydration assessment and spatial mapping10.1109/TBME.2013.2264879 ↗
12. Graphene electronic tattoo sensors10.1021/acsnano.7b02182 ↗
13. Skin impedance measurements with nanomesh electrodes for monitoring skin hydration10.1002/adhm.202001322 ↗
14. Analytical evaluation of the interdigital electrodes capacitance for a multi-layered structure10.1016/j.sna.2004.01.040 ↗
15. Burns · 2008
16. Querleux · 2014
17. Cationic, anionic and neutral polysaccharides for skin tissue engineering and wound healing applications10.1016/j.ijbiomac.2021.10.013 ↗
18. Thermoelastic modelling of the skin at finite deformations10.1016/j.jtherbio.2016.06.017 ↗
19. Does dietary fluid intake affect skin hydration in healthy humans? A systematic literature review10.1111/srt.12454 ↗
20. Skin hydration: interplay between molecular dynamics, structure and water uptake in the stratum corneum10.1038/s41598-017-15921-5 ↗
21. Transepidermal water loss in young and aged healthy humans: a systematic review and meta-analysis10.1007/s00403-012-1313-6 ↗
22. Water modulation of stratum corneum chymotryptic enzyme activity and desquamation10.1007/s004030100257 ↗
23. Skin hydration dynamics investigated by electrical impedance techniques in vivo in vitro10.1038/s41598-020-73684-y ↗
24. Skin hydration measurement and the prediction of the early development of pressure ulcers among at risk adults: a systematic review10.1111/iwj.13934 ↗
25. Textile sensor for skin hydration measurement
26. Capacitive coupling of conducting polymer tattoo electrodes with the skin10.1002/admi.202100352 ↗
27. A review on applications of capacitive displacement sensing for capacitive proximity sensor10.1109/ACCESS.2020.2977716 ↗
28. A fringing field based screen-printed flexible capacitive moisture and water level sensor10.1109/FLEPS49123.2020.9239552 ↗
29. Multi-sized planar capacitive pressure sensor with ultra-high sensitivity10.1016/j.nanoen.2021.106178 ↗
30. Printable flexible sensors for hydration monitoring and moisture measurement in concrete structures10.1088/978-0-7503-3935-3ch3 ↗
31. Recent advances in printed capacitive sensors10.3390/mi11040367 ↗
32. Interdigital sensors and transducers10.1109/JPROC.2004.826603 ↗
33. An epidermal patch for the simultaneous monitoring of haemodynamic and metabolic biomarkers10.1038/s41551-021-00685-1 ↗
34. An epidermal wearable microfluidic patch for simultaneous sampling, storage, and analysis of biofluids with counterion monitoring10.1039/D2LC00183G ↗
35. An elastic and damage-tolerant dry epidermal patch with robust skin adhesion for bioelectronic interfacing10.1021/acsnano.2c07097 ↗
36. Assessment of performance of fringing electric field sensor arrays10.1109/CEIDP.2002.1048945 ↗
37. Edema: diagnosis and management
38. Measurement of coating thickness and loading using concentric fringing electric field sensors10.1109/JSEN.2013.2279991 ↗
39. Optimization of multi-wavelength interdigital dielectrometry instrumentation and algorithms10.1109/94.689431 ↗
40. Planar capacitive sensors—designs and applications10.1108/02602281011010772 ↗
41. Design principles for multichannel fringing electric field sensors10.1109/JSEN.2006.870161 ↗
42. Review of advances in the measurement of skin hydration based on sensing of optical and electrical tissue properties10.3390/s22197151 ↗
43. Validation of a new dielectric device to assess changes of tissue water in skin and subcutaneous fat10.1088/0967-3334/25/2/004 ↗
44. Assessing free and bound water in skin at 300 MHz using tissue dielectric constant measurements with the MoistureMeterD10.1007/978-3-319-14493-1_13 ↗
45. Gender differences in facial skin dielectric constant measured at 300 MHz10.1111/j.1600-0846.2011.00582.x ↗