journal article·2019-03-01Open access

Design trade-offs in amorphous indium gallium zinc oxide thin film transistor based bio-signal sensing front-ends

Mohammad Zulqarnain, Stefano Stanzione, Jan-Laurens P J van der Steen, Gerwin H Gelinck, Sahel Abdinia, Eugenio Cantatore

Abstract

Abstract With the advent of the Internet of things, wearable sensing devices are gaining importance in our daily lives for applications like vital signal monitoring during sport and health diagnostics. Amorphous indium gallium zinc oxide (a-IGZO) thin film transistors (TFTs) fabricated on flexible large-area substrates are a very interesting platform to build wearable sensing devices due to their flexibility, conformability to the human body, and low cost. For this paper four different bio-signal sensing front-end circuits based on a-IGZO TFTs are designed, fabricated, measured and compared, focusing on three performance indicators which are in a trade-off: power efficiency factor (PEF), area occupation and input impedance. Considering a 200 Hz bandwidth, the measured PEF varies between 4.7 × 10 5 and 7.5 × 10 6 . The area occupation spans from 4.2 to 37 mm 2 , while the input impedance at 1 Hz varies from 5.3 to 55.3 MΩ. The front-ends based on diode-load amplifiers are compact but have the lowest input impedance and need external capacitors; a front-end exploiting positive feedback impedance boosting has the highest input impedance and is fully integrated on foil, but occupies the largest area.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Thin-Film Transistor Technologies · Advanced Sensor and Energy Harvesting Materials · Nanowire Synthesis and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (15)

Show source-provided references
1. An EEG acquisition and biomarker-extraction system using low-noise-amplifier and compressive-sensing circuits based on flexible, thin-film electronics10.1109/JSSC.2016.2598295 ↗
2. A micropower low-noise monolithic instrumentation amplifier for medical purposes10.1109/JSSC.1987.1052869 ↗
3. A 0.013 mm2, 5 μW, DC-coupled neural signal acquisition IC with 0.5 V supply10.1109/JSSC.2011.2163552 ↗
4. High-density surface EMG maps from upper-arm and forearm muscles10.1186/1743-0003-9-85 ↗
5. High-resolution EEG (HR-EEG) and magnetoencephalography (MEG)10.1016/j.neucli.2014.11.011 ↗
6. A low-power low-noise CMOS amplifier for neural recording applications10.1109/JSSC.2003.811979 ↗
7. A 2 μW 100nV/√Hz chopper stabilized instrumentation amplifier for chronic measurement of neural field potentials10.1109/JSSC.2007.908664 ↗
8. A 1.8 μW 60 nV/√Hz capacitively-coupled chopper instrumentation amplifier in 65 nm CMOS for wireless sensor nodes10.1109/JSSC.2011.2143610 ↗
9. Low-frequency noise in amorphous indium-gallium-zinc-oxide thin-film transistors10.1109/LED.2009.2015783 ↗
10. Organic thin film transistors: I—compact DC modeling10.1109/TED.2009.2033308 ↗
11. Analogue frontend amplifiers for bio-potential measurements manufactured with a-IGZO TFTs on flexible substrate10.1109/JETCAS.2016.2616723 ↗
12. A fully integrated ΔΣ ADC in organic thin-film transistor technology on flexible plastic foil10.1109/JSSC.2010.2073230 ↗
13. 1 μm-thickness ultra-flexible and high electrode-density surface electromyogram measurement sheet with 2 V organic transistors for prosthetic hand control10.1109/TBCAS.2014.2314135 ↗
14. A 52 μW heart-rate measurement interface fabricated on a flexible foil with a-IGZO TFTs10.1109/ESSCIRC.2018.8494298 ↗
15. A fully integrated 11.2 mm2 a-IGZO EMG front-end circuit on flexible substrate achieving up to 41 dB SNR and 29 MΩ input impedance10.1109/LSSC.2018.2878184 ↗