Effect of Multiple Leaching Cycles on Decay Resistance of Micronized Copper Azole–Treated Southern Pine Sapwood
Source abstract
Abstract
Abstract Copper remains one of the key biocides for protecting timber in soil contact. Historically, copper-based preservatives relied on solubilized copper. Over the past decade, micronized copper systems have largely replaced soluble copper systems in this application. While micronized copper chemistries have been shown to perform well over time with reduced copper leaching compared to solubilized copper, data are lacking on the effects of repeated leaching cycles on resistance of the timber to fungal attack. The potential effects of repeated leaching cycles of micronized copper azole–treated southern pine (Pinus spp.) blocks on both copper losses and resistance to fungal attack were explored over 20 leaching cycles using Gloeophyllum trabeum and Rhodonia placenta as test fungi. Copper losses during leaching were elevated for the first two cycles and steadily declined with additional cycling. There were no noticeable differences in fungal-associated weight losses in blocks exposed to G. trabeum. There was only a slight increase in average block weight losses with R. placenta, although blocks exposed to this fungus experienced higher weight losses with increased leaching cycles. The results suggest that repeated leaching exposures may produce some localized increases in susceptibility to fungal attack, but the overall effects were minor.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Forest Insect Ecology and Management · Forest Ecology and Biodiversity Studies · Wood Treatment and Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (29)
Show source-provided references
1. American Wood Protection Association (AWPA). 2019a. Use category system: User specifications for treated wood. Standard U1-19. In:AWPA Book of Standards. AWPA, Birmingham, Alabama. pp. 5–77.
2. American Wood Protection Association (AWPA). 2019b. Standard method for analysis of treated wood and treating solutions by X-ray spectroscopy. Standard A9-18. In:AWPA Book of Standards. AWPA, Birmingham, Alabama. pp. 175–180.
3. American Wood Protection Association (AWPA). 2019c. Laboratory method for evaluating the decay resistance of wood-based materials against pure basidiomycete cultures: Soil/Block test. Standard E10-16. In:AWPA Book of Standards. AWPA, Birmingham, Alabama. pp. 406–417.
4. Brooks, K. M. 2011. Chapter 7. Migration of preservatives from pressure treated wood. In:Managing Treated Wood in Aquatic Environments. J. J. Morrell, K. M. Brooks, and C. M. Davis (Eds.). Forest Products Society, Madison, Wisconsin. pp. 163–210.
5. Cookson, L. J., J. W. Creffield, K. J. McCarthy, and D. K. Scown. 2008. Australian trials on the efficacy of micronized copper. Document No. IRG/WP/08-30480. International Research Group on Wood Protection, Stockholm.
6. Cooper, P. A. 1991. Cation exchange adsorption of copper on wood. Wood Prot. 1(1):9–14.
7. Cooper, P. A. and Y. T. Ung. 2008. Comparison of laboratory and natural exposure leaching of copper from wood treated with three wood preservatives. Document No. IRG/WP/08-50258. International Research Group on Wood Protection, Stockholm.
8. Cooper, P. A. and Y. T. Ung. 2009. Component leaching from CCA, ACQ and a micronized copper quat (MCQ) system as affected by leaching protocol. Document No. IRG/WP/09-50261. International Research Group on Wood Protection, Stockholm.
9. Dahlgren, S. E. and W. H. Hartford. 1972. Kinetics and mechanism of fixation of Cu-Cr-As wood preservatives. Part I. pH behaviour and general aspects of fixation. Holzforschung26(6):62–69.
10. Duncan, C. and F. F. Lombard. 1965. Fungi associated with principal decays in wood products in the United States. Forest Service Research Paper WO-4. US Department of Agriculture, Washington, D.C.
11. Evans, P. D., A. Limaye, H. Averdunk, M. Turner, T. J. Senden, and M. A. Knackstedt. 2012. Use of X-ray micro-computed tomography to visualize copper in preservative treated wood. Document No. IRG/WP/12-20488. International Research Group on Wood Protection, Stockholm.
12. Freeman, M. and C. R. McIntyre. 2008. A comprehensive review of copper-based wood preservatives. Forest Prod. J. 58(11):6–27.
13. Jin, L. and K. Archer. 1991. Copper based wood preservatives: Observations on fixation, distribution and performance. Proc. Am. Wood Preservers' Assoc. 83:169–184.
14. Jin, L., P. Walcheski, and A. Preston. 2008. Laboratory studies on copper availability in wood treated with soluble amine copper and micronized copper systems. Document No. IRG/WP/08-30489. International Research Group on Wood Protection, Stockholm.
15. Larkin, G. M., J. Zhang, D. L. Richter, R. J. Ziobro, and P. E. Laks. 2008. Biological performance of micronized copper wood preservative formulations in field and laboratory tests. Document No. IRG/WP/08-30488. International Research Group on Wood Protection, Stockholm.
16. Lebow, S. T. 1996. Leaching of wood preservative components and their mobility in the environment—Summary of pertinent literature. General Technical Report FPL-GTR-93. US Department of Agriculture Forest Service, Forest Products Laboratory, Madison, Wisconsin. 36pp.
17. Lebow, S. T. and M. Tipple. 2001. Guide for minimizing the effect of preservative-treated wood on sensitive environments. General Technical Report FPL-GTR-122. US Department of Agriculture Forest Service, Forest Products Laboratory, Madison, Wisconsin. 18pp.
18. McIntyre, C. R. and M. H. Freeman. 2008. Biological efficacy of micronized copper systems. Document No. IRG/WP/08-304085. International Research Group on Wood Protection, Stockholm.
19. Pizzi, A. 1981. The chemistry and kinetic behaviour of Cu-Cr-As/B wood preservatives. I. Fixation of chromium on wood. J. Polym. Sci. Chem. Ed. 19:3093–3121.
20. Pizzi, A. 1982. The chemistry and kinetic behaviour of Cu-Cr-As/B wood preservatives. II. Fixation of the Cu/Cr system on wood. III. Fixation of a Cr/AS system on wood. IV. Fixation of CCA to wood. J. Polym. Sci. Chem. Ed. 20:707–764.
21. Preston, A., L. Jin, D. Nicholas, A. Zahora, P. Walcheski, K. Archer, and T. Schultz. 2008. Field stake tests with copper-based preservatives. Document No. IRG/WP/08-30459. International Research Group on Wood Protection, Stockholm.
22. Ruddick, J. N. R. 1996. The fixation chemistry of copper in basic preservative systems. Proc. Am. Wood Preservers' Assoc. 92:32–49.
23. Ruddick J. N. R. 2003. Basic copper wood preservatives, preservative depletion: Factors which influence loss. Proc. Can. Wood Preservers' Assoc. 24:26–59.
24. Stirling, R. and J. Drummond. 2009. Re-distribution of copper in the cell walls of wood treated with micronized copper quat. Document No. IRG/WP/09-30506. International Research Group on Wood Protection, Stockholm.
25. Stirling, R., J. Drummond, J. Zhang, and R. J. Ziobro. 2008. Micro-distribution of micronized copper in southern pine. Document No. IRG/WP/08-30479. International Research Group on Wood Protection, Stockholm.
26. Xue, W., P. Kennepohl, and J. N. RRuddick. 2010. A comparison of the chemistry of alkaline copper and micronized copper treated wood. Document No. IRG/WP/09-30528. International Research Group on Wood Protection, Stockholm.
27. Ye, M. and J. J. Morrell. 2015. Effect of treatment post-fixation practices on copper migration from alkaline-copper-treated Douglas-fir lumber. Wood Fiber Sci. 47:391–398.
28. Zahora, A. R. 2011. Further studies on the distribution of copper in treated wood using an XRF microscope technique. Document No. IRG/WP/11-40549. International Research Group on Wood Protection, Stockholm.
29. Zhang, J. and J. Horton. 2016. Release of copper from pressure treated wood. Document No. IRG/WP/16-20584. International Research Group on Wood Protection, Stockholm.