journal article·2013

Face Lateral Shear Resistance of One-Row Multistaple Joints in Oriented Strandboard

Samet Demirel, Jilei Zhang, David Jones, Shane Kitchens, William V. Martin, Han Yu

Forest Products Journal· Volume 63· Issue 5-6
Publisher page

Abstract

Abstract Lateral shear resistance capacities of face-to-face single-staple and one-row vertically aligned multistaple joints in three oriented strandboards (OSB) were investigated and compared. Experimental results from testing single-staple joints indicated that the face strand orientation of OSB materials had no significant effect on their staple holding capacity in resisting lateral shear loads. The OSB-III with a density of 35.19 pounds per cubic foot (pcf; 563 kg/m3) had a significantly higher lateral shear resistance capacity than OSB-II, with a density of 29.12 pcf (466 kg/m3). Results of multistaple joints indicated that there was no significant difference in lateral shear load resistance capacities between OSB-II and OSB-III joints. The lateral shear load resistance capacity of multistaple joints increased significantly as the number of staples increased from two to four in increments of one. Two alternative power equations were suggested to estimate the lateral shear load resistance capacity of face-to-face one-row vertically aligned multistaple joints in OSB. One equation requires knowing the lateral shear resistance load of single-staple joints in an OSB material, and the other one requires knowing the density of the OSB material constructing the joints.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Structural Load-Bearing Analysis · Mechanical stress and fatigue analysis · Engineering Structural Analysis Methods

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (10)

Show source-provided references
1. ASTM International. 2010a. Standard test methods for direct moisture content measurements of wood and wood-base materials. ASTM D4442‐92. ASTM International, West Conshohocken, Pennsylvania.
2. ASTM International. 2010b. Standard test methods for specific gravity of wood and wood-base materials. ASTM D2395‐93. ASTM International, West Conshohocken, Pennsylvania.
3. ASTM International. 2010c. Standard methods of testing structural panels in flexure. ASTM D3043‐00. ASTM International, West Conshohocken, Pennsylvania.
4. ASTM International. 2010d. Standard test methods for mechanical fasteners in wood. ASTM D1761‐06. ASTM International, West Conshohocken, Pennsylvania.
5. Demirel, S. 2012. Static and fatigue performance of oriented strandboard as upholstered furniture frame stock. Doctoral dissertation. Mississippi State University. URN: etd-03212012‐085200.
6. Eckelman, C. A. and Y. Z. Erdil. 2000. Joint design for furniture frames constructed of plywood and oriented strand board. http://www.ces.purdue.edu/extmedia/FNR/FNR-170.pdf. Accessed August 23, 2013.
7. Erdil, Y. Z., J. Zhang, and C. A. Eckelman. 2003. Staple holding strength of furniture frame joints constructed of plywood and oriented strandboard. Forest Prod. J. 53(1):70–75.
8. Forest Products Laboratory. 2010. Wood handbook—Wood as an engineering material. General Technical Report FPL-GTR-190. USDA Forest Service, Forest Products Laboratory, Madison, Wisconsin. 508 pp.
9. Yadama, V., J. Zhang, B. M. Syed, and P. H. Steele. 2002. Experimental analysis of multiple staple joints in selected wood and wood-based materials. J. Testing Eval. 30(5):400–407.
10. Zhang, J. and M. Maupin. 2004. Face lateral and withdrawal resistances of staple joints in furniture-grade pine-plywood. Forest Prod. J. 54(6):40–46.