journal article·2024-12-01

Recent Full-Scale Mechanical and Creep Testing of Structural Insulated Panels (SIPs): A Summary

Laya Khademibami, Rubin Shmulsky, Christopher Adam Senalik, Roy Daniel Seale, Robert J. Ross, Mostafa Mohammadabadi, Thomas Williamson, Seyed Abolghasem Fatemi

Forest Products Journal· Volume 74· Issue S2
Publisher page

Abstract

Abstract The effects of foam core density, foam discontinuity in the shear zone, and flexural properties based on the effect of duration of load testing on structural insulated panels (SIPs) were investigated. These characteristics were individually evaluated for two SIP depths: 6.5 inches and 12.25 inches. For each of the two depths, SIP specimens were assigned to short-duration 1/3-point bending tests and the other matched SIP specimens were subjected to a 90-day creep test, followed by short-duration 1/3-point bending tests. Half of the specimens contained a foam density of 1.0 lb/ft3 and the other half with 1.2 lb/ft3. Likewise, half of the panels contained an expanded polystyrene (EPS) discontinuity in the bending test shear zone, whereas the other half did not have such joints or discontinuities. The findings showed that SIPs with no EPS discontinuity were approximately twice as strong as those with EPS discontinuity. Regardless of depth classes, the SIP specimens with foam density of 1.2 lb/ft3 had a higher Pmax and lower Δymax. Additionally, there was no significant difference for Pmax and Δymax before and after creep testing within the 12.25-inch depth class or for Pmax for the 6.5-inch-deep specimens, but Δymax increased by approximately 7 percent after the creep test in the 6.5-inch-deep specimens. Results indicated that specimens with no foam discontinuity in shear critical areas had more strength in comparison with the specimens with a foam discontinuity and higher density foam cores were stronger for the specific flexural strength test conditions regardless of depth classes.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Structural Analysis of Composite Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (14)

Show source-provided references
1. Ahmed, · 2016
2. Aldrich, · 2010
3. ASTM International · 2015
4. The structural behavior of hybrid structural insulated panels under pure bending load10.14716/ijtech.v8i5.861 ↗
5. Flexural testing of structural insulated panels before and after creep testing10.15376/biores.18.2.3319-3327 ↗
6. The influence of foam density on the flexural properties of structural insulated panels10.13073/FPJ-D-23-00034 ↗
7. McDonald, · 2014 · 1210.2737/FPL-RN-332 ↗
8. McDonald, · 2018 · 1210.2737/FPL-RP-697 ↗
9. Morley, · 2000
10. SAS Institute · 2013
11. Seale, · 2024 · 2010.2737/FPL-RN-426 ↗
12. The influence of foam discontinuity in the shear zone of structural insulated panel beams10.22382/wfs-2022-18 ↗
13. Steel, · 1980
14. New thin shell made of composite structural insulated panels10.1177/0731684414549492 ↗