Mechanical Behavior of PET-G Tooth Aligners Under Cyclic Loading
Source abstract
Abstract
Invisible aligners are medical devices, which allow repositioning of teeth through a treatment designed by the orthodontists. During this orthodontic treatment, patients use several aligners each for a couple of weeks. The aligner will apply a system of forces on the teeth to shift them into desired position. Since aligners exert forces thanks to their particular shape, it is important that during lifetime's service they do not undergo significant deformations. This research aims to study the mechanical behavior of invisible aligners made by polyethylene terephthalate-glycol (PET-G), which is one of most used the plastic materials to produce these devices. In this study, cyclic compression tests in atmospheric environment (~25°C) as well as in the presence of saliva (to simulate intraoral environment) were performed. The mechanical behavior of two different thicknesses aligners (0.75 and 0.88 mm) was studied. In particular, each aligner was subjected to 22500 load cycles from 0 to 50 N. The number of load cycles simulates the average load history to which an aligner is subjected during its lifetime. The tests were performed on a testing machine, using a hard resin dental casts appropriately fixed to the machine. Analysis of the results shows that stiffness of aligners material increases during the cyclic test. In particular, it was observed a gradual reduction of crosshead displacement during the test, highlighting the occurrence of cyclic hardening phenomena. It was also found that the aligners show a residual strain recovery after removing the applied load. Moreover, in the analyzed load range rate, the aligners show a low tendency to accumulate residual strains as loading cycles progress.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Orthodontics and Dentofacial Orthopedics · Dental Implant Techniques and Outcomes · dental development and anomalies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (33)
Show source-provided references
1. Stress relaxation behavior after cyclic preloading in polypropylene.10.1002/pen.760332209 ↗
2. Viscoelastic-plastic behaviour with mean strain changes in polypropylene.10.1007/bf00352678 ↗
3. An update on present and future considerations of aligners.10.1080/19424396.2006.12222250 ↗
4. Finite strain behavior of poly (ethylene terephthalate) (PET) and poly (ethylene terephthalate)-glycol (PETG).10.1016/j.polymer.2005.03.083 ↗
5. Intraoral aging of orthodontic materials: the picture we miss and its clinical relevance.10.1016/j.ajodo.2004.09.015 ↗
6. Mechanical characterization of thermoplastic aligner materials: recommendations for test parameter standardization.10.1155/2019/8074827 ↗
7. Dynamic stress relaxation of orthodontic thermoplastic materials in a simulated oral environment.10.4012/dmj.2013-131 ↗
8. Social perceptions of adults wearing orthodontic appliances: a cross-sectional study.10.1093/ejo/cjq069 ↗
9. The philosophy of the tooth positioning appliance.10.1016/0096-6347(45)90101-3 ↗
10. Surface damage behavior of polyurethane O-rings in automated material handling system for glass panels.10.1007/s12541-016-0006-z ↗
11. Cyclic steady state stress-strain behavior of UHMW polyethylene.10.1016/s0142-9612(00)00138-1 ↗
12. Force delivery properties of thermoplastic orthodontic materials.10.1016/j.ajodo.2006.03.034 ↗
13. Landel · Mechanical Properties of Polymers and Composites. · 199310.1201/b16929 ↗
14. Comparison of Essix and Hawley retainers.
15. The use of vacuum formed splints for temporary intermaxillary fixation in the management of unilateral condylar fractures.10.1054/bjom.2001.0649 ↗
16. Stress relaxation properties of four orthodontic aligner materials: a 24-hour in vitro study.10.2319/113015-813.1 ↗
17. Mechanical properties of orthodontic thermoplastic PETG/PC2858 after blending.10.3290/j.cjdr.a35696 ↗
18. Invisible retainers.
19. The vacuum formed dental contour appliance.
20. Use of thermoplastic vacuum-formed matrix for emergency management of crown-root fracture.10.1016/s0022-3913(07)60109-7 ↗
21. The essential work of fracture of thermoplastic orthodontic retainer materials.10.2319/042809-232.1 ↗
22. Der Osamu-Retainer und sein Indikationsbereich. Kieferorthop, Prakt.
23. Invisible retainers.10.1016/0002-9416(71)90099-6 ↗
24. Effect of humidity on the indentation hardness and flexural fatigue behavior of polyamide 6 nanocomposite.10.1016/j.msea.2010.01.070 ↗
25. The mechanical properties of dental thermoplastic materials in a simulated intraoral environment.10.1016/j.odw.2006.03.003 ↗
26. A new equipment to measure the combined effects of humidity, temperature, mechanical stress and UV exposure on the creep behaviour of polymers.10.1016/j.polymertesting.2007.08.005 ↗
27. Schrauwen · Deformation and Failure of Semicrystallie Polymer Systems: Influence of Micro and Molecular Structure. · 2003
28. Cyclic deformation behavior of an epoxy polymer. part I: experimental investigation.10.1002/pen.20251 ↗
29. Bleaching teeth during supervised retention.
30. Technology for the fabrication of temporary anterior bridges.
31. Properties of aligner materia Ex30
32. Quantification of water diffusion in CMP pad polymers and impact on mechanical properties.10.1149/2.0121511jss ↗
33. Preparation and characterization of thermoplastic materials for invisible orthodontics.10.4012/dmj.2011-120 ↗