Experimental investigation of EPS geofoam seismic buffers using shaking table tests
Source abstract
Abstract
The paper reports the results of six shaking table tests using reduced-scale model walls constructed with expanded polystyrene (EPS) panels to reduce dynamic earth loads due to base shaking. The results are compared with a nominal identical rigid (control) wall constructed without a seismic buffer. The test results show that dynamic load attenuation increased with decreasing geofoam stiffness. The test with the highest buffer stiffness resulted in a 15% reduction in dynamic load and the test with lowest stiffness resulted in a 40% reduction in dynamic load compared with the control wall. The results of these experiments provide proof of the concept that EPS panels placed against rigid walls can act as seismic buffers to attenuate dynamic loads due to ground shaking (e.g. earthquake). Additional quantitative data related to load–deformation–time response, back-calculated elastic modulus values for the EPS seismic buffer configurations, dynamic interface shear properties, acceleration amplification in the backfill soil and post-excitation stress relaxation-creep behaviour are also reported.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Geotechnical Engineering and Soil Stabilization · Geotechnical Engineering and Underground Structures · Geotechnical Engineering and Soil Mechanics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
GeoEngineering Centre at Queen's-RMC, Department of Civil Engineering, Queen's University Kingston, Ontario, K7L 3N6, Canada Telephone: , Telefax: ,
GeoEngineering Centre at Queen's-RMC, Department of Civil Engineering 13 General Crerar, Sawyer Building, Room 2085, Royal Military College of Canada, Kingston, Ontario, K7K 7B4, Canada Telephone: , Telefax: ,
References (24)
Show source-provided references
1. 10.1680/gein.2007.14.3.16510.1680/gein.2007.14.3.165 ↗
2. AASHTO · 2002
3. ASTM C 578-06
4. ASTM 6817-06
5. 10.1680/gein.5.011710.1680/gein.5.0117 ↗
6. 10.1016/j.soildyn.2006.08.00310.1016/j.soildyn.2006.08.003 ↗
7. 10.1016/j.soildyn.2006.07.00410.1016/j.soildyn.2006.07.004 ↗
8. 10.1680/ijpmg.2004.04040210.1680/ijpmg.2004.040402 ↗
9. Gaskin P. A. Geofoam Buffers for Rigid Walls: An Investigation into the Use of Expanded Polystyrene for Seismic Buffers. Msc thesis, 2000, Civil Engineering Department, Queen's University, Kingston, Ontario, 255–255.
10. 10.1016/S0267-7261(00)00010-510.1016/S0267-7261(00)00010-5 ↗
11. Hazarika H. · 2003 · 1244
12. Horvath J. S. Geofoam Geosynthetic, 1995, Horvath Engineering, Scarsdale, NY, 217–217.
13. 10.1016/S0266-1144(97)00008-310.1016/S0266-1144(97)00008-3 ↗
14. 10.3208/sandf1972.29.10510.3208/sandf1972.29.105 ↗
15. Inglis D. · 1996 · 18
16. Itasca · 1996
17. 10.1016/0266-1144(92)90040-H10.1016/0266-1144(92)90040-H ↗
18. McGown A. · 1987
19. McGown A. · 1988 · 193
20. Negussey D. · 2002 · 1
21. Partos A. M. · 1987 · 628
22. Paz M. Structural Dynamics: Theory and Computation, 1994, Chapman and Hall, New York, 825–825.
23. 10.1680/gein.8.020410.1680/gein.8.0204 ↗
24. Zarnani S. · 2005 · 11