ABSTRACT: This technical paper presents the results of a test pad at an operating municipal solid waste landfill that measured pressures applied to the primary geomembrane in the double composite liner system used at the site. The pressures were measured with two pressure cells placed on top of the geomembrane and covered with varying thicknesses of sandy structural fill and rounded stone, i.e. a leachate collection and removal layer stone. The pressures were applied by two types of dozers to investigate the magnitude of applied pressures and the effect of equipment on the applied pressure. In general, the results show increased pressure with decreasing cover layer thickness, increasing speed, and turning over of the pressure cells. The data can be used to estimate the minimum layer thickness to limit the pressure applied to an underlying geomembrane to a tolerable value, e.g. 41.4 kPa, and prevent geomembrane damage or puncture during construction.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Landfill Environmental Impact Studies · Geotechnical Engineering and Soil Stabilization

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Professor of Civil and Environmental Engineering, 2217 Newmark Civil Engineering Laboratory, University of Illinois, 205 N. Mathews Ave., Urbana, IL 61801, USA, Telephone: +1 217 333 7394, Telefax: +1 217 333 9464, E-mail: tstark@illinois.edu

Graduate Research Assistant, Department of Civil and Environmental Engineering, 2217 Newmark Civil Engineering Laboratory, University of Illinois, 205 N. Mathews Ave., Urbana, IL 61801, USA, Telephone: +1 217 333 7394, Telefax: +1 217 333 9464, E-mail: pazmino1@uiuc.edu

Senior Project Engineer, Barton & Loguidice, 290 Elwood Davis Road, Box 3107, Syracuse, NY 13220, USA, Telephone: +1 315 457 5200, Telefax: +1 315 451 0052, E-mail: CMcDowell@bartonandloguidice.com

Project Engineer, Barton & Loguidice, 290 Elwood Davis Road, Box 3107, Syracuse, NY 13220, USA, Telephone: +1 315 457 5200, Telefax: +1 315 451 0052, E-mail: RPhaneuf@bartonandloguidice.com

References (12)

Show source-provided references
1. ASTM D 6747
2. ASTM D 7002
3. ASTM D 7007
4. Barton & Loguidice · 2007
5. Geokon · 2007
6. Geokon · 2009
7. Giroud J. P. · 1982 · 1 · 37
8. ISO-6747 · 1998
9. Jeon S.-S. · Geosynthetics International · 2011 · 18 · 33210.1680/gein.2011.18.5.332 ↗
10. NYSDEC · 1999
11. 10.1002/9780470172766.ch510.1002/9780470172766.ch5 ↗
12. Trimble · 2009