Geotextile Filtration Tests on Two Brazilian Soils and Current Filter Criteria
Source abstract
Abstract
This paper presents results of filtration tests with geotextiles in combination with a uniform fine sand and a clayey fine sand. The tests with the clayey sand were long term tests during which the pH, electrical conductivity and turbidity of the percolation water were monitored with time. These observations, together with a detailed measurement of permeability values, indicate that the three geotextiles performed adequately with regard to drainage and soil particle retention. It is shown that current geotextile filter design criteria are conservative and only one among six criteria was able to predict the behavior of all the geotextiles tested.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Geotechnical Engineering and Soil Stabilization · Landfill Environmental Impact Studies · Geotechnical Engineering and Underground Structures
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
COPPE-Graduate School of Engineering, Federal University of Rio de Janeiro, P.O. Box 68506, 21945-970, Rio de Janeiro, Brazil, Telephone: 55/21-280-9993, Telefax: 55/21-290-6626
Brazilian Federal Railway Network, 86 Procopio Ferreira Sq., Room 602, 20221-030, Rio de Janeiro, Brazil, Telephone: 55/-21-233-7791, Telefax: 55/21-516-2488
References
Reference metadata was not supplied for this record.